3
SPECIFICATIONS
NATURAL GAS
PROPANE
Input Rating (Btu/hr) (0-1370 m)
37,000
37,000
Min. Input Rating (Btu/hr) (0-1370 m)
5,000
7,500
Injector Sizes (DMS) (front/center/rear (0-1370 m)
47/56/44
57/71/55
Manifold Pressure (in w.c./kPa)
3.5/0.87
10.0/.49
Minimum Manifold Pressure (in w.c./kPa)
1.7/0.4
5.9/1.47
Minimum Inlet Pressure (in w.c./kPa)
5.0/1.5
11.0/.74
Maximum Output (Btu/hr) (0-1370 m)
7,600
8,400
AFUE (seasonal efficiency; minimum venting)
64.9
%
67.0
%
Steady State Efficiency (max. input, blower on High)
77.
%
78.6
%
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
Unit to side wall or combustible trim ....................................10 in. (54 mm)
Unit to mantel and combustible trim, unprotected ................1 in. (305 mm)
Electrical Rating: 10 Volts, 60 Hz., 1. Amp
Tested to ANSI Z1.88-00, CSA .33-M0,
CAN/CGA .17-M91.
44 (std.)
40 (opt.)
32.5 (std) 30 (opt)