25
INSTALLATION
Only For Qualified Installers
Changing to LP
Remove pilot tower
with a 7/16” wrench.
Replace Natural Gas
orifice with LP
orifice.
Remove screw
Remove Air
Deflector
Remove Orifice
Cover
Remove Screw
Remove
Flame Bridge
Lift up on front of burner/grate/
screen assembly and then slide
left about 1/2”. The assembly can
then be removed.
Remove Rear Burner by
sliding to the left.
1
2
3
5
4
6
7
8
Top Vent LP Kit
Part No. 1-00-08770
Rear Vent LP Kit
Part No. 1-00-08771
LP Orifice Box Cover
LP Conversion label
LP Pilot Orifice
LP Front Orifice #52
LP Rear Orifice.
#60 Rear Flue,
#59 Top Flue.
LP Valve
Conversion
Module
LP Conversion
Instructions
These kits are only for use in the Serenity series fireplaces.
Note: The difference between the top and rear LP kit is the
size of the rear orifice (#59 for top and #60 for rear).
LP Conversion Kit