background image

Harman Stove Company warrants its products to be free from defects in material or workmanship, in normal use

and service, for a period of 6 years from the date of sales invoice and for mechanical and electrical failures, in normal use
and service, for a period of 3 years from the date of sales invoice.

If  defective  in material  or  workmanship,  during  the warranty  period,  Harman  Stove  Company  will, at  its  option,

repair or replace the product as described below.

The warranty above constitutes the entire warranty with respect to Harman Stove Company products.  HARMAN

STOVE COMPANY  MAKES  NO  OTHER  WARRANTY,  EXPRESSED  OR  IMPLIED,  INCLUDING  “ANY”

WARRANTY  OF MERCHANTABILITY,  OR  WARRANTY  OF  FITNESS  FOR  A  PARTICULAR  PURPOSE.  No
employee, agent, dealer, or other person is authorized to give any warranty on behalf of Harman Stove Company.  This
warranty does not apply if the product has been altered in any way after leaving the factory.  Harman Stove Company and

its agents assume no liability for “resultant damages of any kind” arising from the use of its products.  In addition, the

manufacturer and its warranty administrator shall be held free and harmless from liability from damage to property related
to the operation, proper or improper, of the equipment.

THERE  ARE   NO  WARRANTIES   WHICH  EXTEND   BEYOND  THE   DESCRIPTION  ON   THE  FACE

HEREOF.

THESE  WARRANTIES  APPLY only if the device is installed and operated as recommended in the user’s manual.

THESE  WARRANTIES WILL  NOT  APPLY if abuse, accident, improper installation, negligence, or use beyond

rated capacity causes damage.

HOW    TO  MAKE  A  CLAIM  -  Any  claim  under  this  warranty  should  be  made  to  the  dealer  from  whom  this

appliance  was  purchased.   Then  contact  is made  with  manufacturer,  giving  the model  and  serial  numbers, the  date  of

purchase, your dealer’s name and address, plus a simple explanation of the nature of the defect.  Extra costs such as

mileage and overtime are not covered.  Nuisance calls are not covered by these warranties.

THIS   WARRANTY   IS   LIMITED   TO   DEFECTIVE   PARTS - REPAIR   AND/OR   REPLACEMENT   AT

HARMAN   STOVE  COMPANY’S   OPTION   AND   EXCLUDES   ANY  INCIDENTAL   AND   CONSEQUENTIAL

DAMAGES   CONNECTED  THEREWITH.

WARRANTY  EXCLUSIONS:  Failure due,  but  not  limited  to, fire,  lightning,  acts  of  God, power  failures  and/or

surges, rust, corrosion and venting problems are not covered.  Damage and/or repairs including but not limited to; remote
controls,  filters,  fuses,  knobs,  glass,  ceramic  brick  panels,  ceramic  fiber  afterburners,  door  packing,  tile,  ceramic  log
sets,  paint,  batteries or  battery  back-up  and related  duct  work  are  not covered. Also  excluded  from this  warranty  are
consumable  or normal  wear  items  including but  not  limited to;  flame  guides, grates,  coal  bars,  afterburner hoods,  fire
brick, gaskets. Additional  exclusions for corn stoves are  burnpot housing weldment, burnpot grate  weldment (pellet or
corn),  burnpot  front  plate  (pellet  or  corn),  burnpot  front  plate  lock,  corn  auger  extension,  ceramic  insert,  and  ceramic
insert plate. Additional or unusual utility bills incurred due to any malfunction or defect in equipment and the labor cost of
gaining access to or removal of a unit that requires special tools or equipment are not covered.  Maintenance needed to

keep the stove in “good operating condition” is not covered.  This includes, but is not limited to, cleaning, adjustment of

customer  controls  and  customer  education.    Labor,  materials,  expenses  and/or  equipment  needed  to  comply  with  law
and/or regulations set forth by any governmental agencies are not covered.

This Warranty provides specific legal rights and the consumer may have other rights that vary from state to state.
In the  event of  change in  ownership, the  remaining portion  of this  warranty may  be transferred  to the  new owner

by sending the new owner information and a transfer fee of $25.00 US to the Harman Stove Company.

PLEASE  READ  THE   LITERATURE  BY  THE  MANUFACTURER  FOR   THE  VARIOUS  ACCESSORY

DEVICES.   THE MANUFACTURER  WARRANTS  THESE  ACCESSORY  DEVICES,  NOT  HARMAN  STOVE
COMPANY  OR  THEIR WARRANTY  ADMINISTRATOR.   FURTHERMORE,  THESE  ACCESSORY  DEVICES
MUST  BE  INSTALLED  AND  USED ACCORDING  TO  THE  RECOMMENDATIONS  OF  THE  MANUFAC-
TURER.

REMEDIES - The remedies set forth herein are exclusive and the liability of seller with respect to any contract or

sale or  anything done in  connection therewith, whether  in Contract, in  tort, under any  warranty, or otherwise,  shall not,
except as herein expressly provided, exceed the price of the equipment or part of which such liability is based.

CLARIFY - The above represents the complete warranty, which is given in connection with stoves, manufactured

by Harman Stove Company.  No other commitments, verbal or otherwise, shall apply except by a written addendum to
this  warranty.

HARMAN GOLD WARRANTY 

(for corn stove)

6 YEAR TRANSFERABLE LIMITED
WARRANTY (Residential)

1 YEAR LIMITED WARRANTY (Commercial)

Summary of Contents for PC 45

Page 1: ...FETY FOLLOW INSTALLATIONDIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS INYOUR AREA CONTACT YOUR LOCAL AUTHORITY SUCH AS MUNICIPAL BUILD...

Page 2: ...2 PC 45 Corn Pellet Stove...

Page 3: ...Sidewinder Burn Pot allows corn to be burned from three days up to a week without cleaning depending on the corn s moisture level and burn rate Automatic Ignition allows you to fill the hopper set yo...

Page 4: ...cover panels are removed from the stove to make it easier to get at the hold down bolts The rear cover panels are packed inside the hopper and should be installed on the stove as shown It is recommend...

Page 5: ...o clock position Does the door rope compress If not loosen the set screw turn the paw bolt one more turn into the door Repeat as required to achieve a tight door fit NOTE Remember to thoroughly clean...

Page 6: ...me are closed If this readingis more than 05 higher thanthe unconnected reading check for possible restrictions or the need for outside air See page 8 Mobile Home Installation When installing this uni...

Page 7: ...hen measured fromthe horizontalcenter line of the regu lator 1 I The clearance to service regulator vent outlet must be a minimum of 6 feet 1 J The clearance to a non mechanical air sup ply inlet to t...

Page 8: ...ide surface temperature to allow a clearance to combustibles of only 3 inches The sections of pipe lock together to form an air tight seal in most cases however in some cases a per fect seal is not ac...

Page 9: ...tural draft in the event of a power failure 2 Preferred method This method also provides excellent venting for normaloperation but requires the stove tobe installed farther from the wall The vertical...

Page 10: ...you may want to install a liner as in method 6 4 Installing into an existing fireplace chimney US only This method provides excellent venting for nor mal operation This method also provides natural dr...

Page 11: ...sure to use approved pellet vent pipe fittings Seal pipe joints with silicone in addition to the sealing system used by the manufacturer Pipesize shouldbe increased to 4 using this method 6 Installing...

Page 12: ...19 Fig 20 7 Installing through the ceiling vent Through the ceiling vent follow PL vent manufacturers recommendations when using wall and ceiling pass through DO NOT INSTALL A FLUE DAMPER IN THE EXHAU...

Page 13: ...with a 3 setting being the maximum setting 1 the lowest setting This set ting will vary depending on the quality of corn used When burning pellets the feed rate setting can be adjusted within the ful...

Page 14: ...s you to check the motors for operation NOTE The auger motor will not operate with the view door or ash door open NOTE The initial start upona newstove may require the corn to be purged into the burnp...

Page 15: ...l board setting The unit can only go to low burn and will remain there until it runs out of fuel or until more heat is needed and the feed rate in creases Feed rate adjustments and dial settings are t...

Page 16: ...n the Temperature Dial to the desired setting 4 Clean the burnpot and housing if necessary 5 Fill the burnpot with pellets so that the auger tube opening is covered and slopes away from the auger tube...

Page 17: ...ithin off position band except after normal shut down Blinks to indicate errors listed below Indicates power to distribution blower 6 Blinks Indicates that the control has calculated poor or incomplet...

Page 18: ...bustion Motor Speed Control Low draft only set point The small straight screwdriver slot is plastic therefore the unit can be adjusted while in operation Fig 29 Fig 30 A simple draft test should be pe...

Page 19: ...e to carry and dispose of ashes 3 Slide the ash pan back into the stove Cleaning If you have been burning corn the stove will need to be cleaned approximately once a month The amount of corn burned an...

Page 20: ...ing nut on the feeder cover and slide the cover off the threaded rod 3 Remove all fines with a vacuum Fig 37 Brush not supplied Can be found in hardware stores Fig 33 Latch closed with blower coverin...

Page 21: ...against the burnpot grate and housing 9 Install the front plate lock 10 The dirty auger extension burnpot grate and front plate just removed can now be cleaned for the next scheduled maintenance NOTE...

Page 22: ...s restricting fuel flow 4 Feed motor or draft motor has failed 5 Power failure or blown fuse SMOKE IS VISIBLE COMING OUT OF VENT 1 Air fuel ratio is too rich A Feed rate too high B Draft too low cause...

Page 23: ...Mounting Bolts 3 30 1311812513 Air Pump 3 20 02679 Air Pump Mounting Hardware BHSCS 8 32 x 1 4 3 30 3108320252 3 8 MPT x 1 4 Barb Brass Inlet Fitting 3 10 724203 Pusher Arm Mtng Bolts 4 3 30 22520050...

Page 24: ...all the hold down clips and tighten with bolts as shown on page 5 To install ash lip trim simply slide the trim over the ash lip and into the groove on the trim Gold Door The gold door fig 43 is assem...

Page 25: ...or should be installed in the loca tion where you want to control the temperature NOTE Distances of more than 25 feet from the unit or in another room are not recommended The room sensor is essentialf...

Page 26: ...26 PC 45 Corn Pellet Stove PC 45 Wiring Diagram...

Page 27: ...9301 5 Single Fan Blade 3 20 40985 Combustion Blower 3 21 08639 Distribution Blower 3 21 22647 Hopper Lid Latch 3 31 199110 3 16 Rubber Washer for Hopper Lid 3 31 90131101 Power Cord 3 20 29685 Fire B...

Page 28: ...Damage and or repairs including but not limited to remote controls filters fuses knobs glass ceramic brick panels ceramic fiber afterburners door packing tile ceramic log sets paint batteries or batt...