26
PF100
8.
Turn the Temperature Dial
on the furnace
control to “NORMAL SETTING”.
9.
Turn Mode Selector
to “AUTOMATIC”
This will start the lighting process if the tempera-
ture at the wall control is less than the set temperature
on the dial.
The PF100 is more than just an automatic ignition
pellet furnace. The automatic system will allow the fire
size to be adjusted to match the heating needs and even
put the fire out if necessary. If heat is needed after the
fire is out, the PF100 will automatically re-ignite and
adjust the fire size to match the heating need.
10.
Fill hopper
with pellets and
remove
ashes
as required.
Fig. 53
Type of Fuel
Use pelletized wood only.
Note:
The lower the
ash content of the pellets the less cleaning that will be
needed of the heat exchanger surfaces. The cleaner these
surfaces are kept, the more efficient the furnace will be.
NOTE: Do not burn garbage, gasoline, naphtha,
engine oil, or other inappropriate materials in the
PF100.
Store pellets in the manufacturer’s wrapping
until needed to prevent pellets from absorbing
moisture. Do not store fuel within the appliance
installation clearances, or within the space required
for fueling, ash removal, and other routine
maintenance operations.
This is the Control setting that will allow the Wall
Control to function.
Temp Dial Mode Selector
...
...
Operation
Fig. 54
Summary of Contents for PF-100 Furnace