Installation
Only For Qualified Installers
Door Latches
Remove door by pulling latches out as shown and
pulling the bottom of the door out from the unit about
3”. Then lift the door slightly up and off the hooks.
Door Hooks
1
Remove air plate by lifting it up about 3 inches and
then out of firebox. Be careful not to damage side
brick panels
Converting to Natural Gas
The pilot must be placed in accordance with the above
sketch for proper burner ignition.
Pilot
Burner
2
3
4
Remove log. Next, remove screw, washer and
spacer from the center of the rear brick panel. Using
one hand, gently push the side brick/relief door open
slightly and using the other pull the top of the rear
brick panel forward and remove it.
Remove the screws mounting the intake air deflector and
lift it from the firebox. Next locate the screw holding the
burner tube to the firebox floor and remove it. Now the #50
LPG burner orifice can be removed using a 1/2” deep well
socket and replaced with a # 31 natural gas orifice.
Remove screw holding pilot air deflectors, and the
deflectors, to allow access to the pilot tower. using a 7/16”
wrench, take out the LP orifice and replace it with the
natural gas orifice. Reassemble components adjusting
pilot air deflectors allowing burner tube to slide over
them and into place. Pilot orfices are marked NG and LP
appropriately.
15