Only For Qualified Installers
Connecting the
Optional Thermostat
If the optional thermostat is used, it must be plugged into
the terminal strip located in the lower left front corner
of the heater.
When installing a millivolt control system, use only a
special low resistance thermostat. DO NOT USE A
REGULAR HEATING THERMOSTAT.
Be sure that all electrical connections are clean, free from
corrosion, and tight. Inspect connections periodically to
confirm that no corrosion has built up over time.
When properly installed and maintained, a millivolt
control system should give many years of trouble-free
service.
It is important to use the proper gauge wire for the
length used.
RECOMMENDED WIRE GAUGES
Maximum
Wire
Length
Gauge
100’
14
60’
16
40’
18
25’
20
15’
22
Thermostat
Remote Control
The button on the remote control can be used to turn
the burner on and off.
This remote uses an ultrasonic control method and does
not need to be pointed directly at the fireplace.
A hand held sending unit, receiving unit, mounting
bracket and all wiring are included when you order the
remote control.
Installation instructions are packed with remote kit.
Burner Button
Part # 3-20-12080
Part # 1-00-7911