Harman TL300

Clearances

Clearance is the empty space required between the stove 

or chimney connector and the nearest combustible surface or 

object, such as walls, ceilings, floors, or furniture.  Clearance 

distances may only be reduced by using methods approved 

by either the CAN/CSA B365 standard (Canada) or NFPA 

211 (U.S.)  Contact your building authority for information 

if you are interested in reducing clearance distances below 

those presented here.

Parallel versus Corner Installations

A parallel installation is one in which the back and sides of 

the stove are parallel to the walls behind and to the side of the 

stove.  A corner installation is one in which the back of the 

stove is positioned diagonally across a corner of the room.  

Each installation requires its own set of clearances.

For parallel installations, the required clearance distances 

from the stove are:  

1) to the side wall, 20" (508 mm); 

2) to the back wall, 18" (458 mm). 

3) From the chimney connector to the wall, 31"(787 mm) 

4) Hortizontal pipe to the ceiling, 15"(381 mm).

NOTE

:  For a vertical chimney connector in a parallel instal-

lation the distance from the connector to the side wall must 

be 31"(787 mm), due to the required side clearance of the 

stove itself.  Fireplace installations must meet these same 

clearance requirements; specifically follow these guidelines 

for mantel and trim clearances.

For corner installations, the clearance distances from the 

stove are 18"(458 mm) from each corner of the stove mea-

sured straight to the nearest combustible material, and 27" 

(686 mm) from the chimney connector to the walls.

From the front of the stove, clearance to combustible ma-

terials such as furniture, curtains, fuel, etc.:  48"(1220 mm) 

in the 

U.S

. and 60"(1524 mm) in 

Canada. 

Due to excessive 

heat build-up at the wall passthrough, using double wall 

pipe, horizontal venting is only approved into a masonry 

chimney.

See Detailed Clearances on Page 9

installation

Mobile Home Installation

The TL300 is approved for mobile home installations in 

the US only. Mobile Home installation should be done in ac-

cordance with the Manufactured Home and Safety Standard 

(HUD), CFR 3280, part 24.

When installing the TL300 in a mobile home, several re-

quirements must be met:

1. The unit must be bolted to the floor. This can be done 

through the rear of the pedestal with 3" lag screws, using the 

holes where the unit was bolted to the shipping pallet.

2. The unit must be connected to outside air. See Outside 

air section on page 21.

3. Floor protection and specified clearances to combus-

tibles must be followed.

4. Unit must be grounded to the metal frame of the mo-

bile home.

5.  Smoke  detectors  and/or  smoke  alarms  are  recom-

mended on each floor of the house. Note that when loading 

fire, some smoke seepage may occur, and set off the alarm. 

Ventilate as necessary to eliminate the problem. If the alarm 

should sound otherwise, cease the use of the appliance and 

call your dealer for service.

Floor protector/ protection de sol (Min. 51" x 44")

(450 mm)

(200 mm)

(200 mm)

(200 mm)

8"

8"

8"

18"

51" (1275 mm)

44" (1100 mm)

Floor Protection

Floor protection is required under your TL300. This floor 

protection must be a minimum of 20 ga. sheet metal in thick-

ness, it can also be stone or tile or other masonry material, 

providing it is non-combustible. This floor protection must 

extend 18 inches in front of the door opening and 8 inches to 

each side and to the rear of the stove body. There must also 

be floor protection under any horizontal sections of venting 

regardless of their height from the floor.

MOBILE HOME REGULATIONS DO NOT 

ALLOW INSTALLATION IN ANY ROOM 

DESIGNATED FOR SLEEPING.

Summary of Contents for TL300

Page 1: ...ble for installation in a mobile home us only IF THIS wood burning STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLLOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA Contact your local authority such as municipal building department fire department fire prevention bureau etc to det...

Page 2: ...2 Harman TL300 ...

Page 3: ...re to follow instructions may result in property damage bodily injury or even death Index Hearth Home Technologies Inc 352 Mountain House Road Halifax PA 17032 U S A Introduction 4 Specifications 5 Installation 8 Venting 10 Operation Building a Fire 16 Maintenance 19 Options 21 Service Parts 22 Warranty 26 ...

Page 4: ...EUblES oUAUtrES obJEStAriSqUE Listed soLid FueL FirepLace stove or room Heater appareiL de cHauFFage ou poeLe a combustibLe soLide Model Modele Tl300 Serial NuMber NuMero de Serie CLEARANCE TO COMBUSTIBLE SURFACES A Unit to Sidewall B Unit to Backwall C Chimney Connector to Sidewall D Chimney Connector to Backwall E Unit to Adjacent Wall F Chimney Connector to Adjacent Wall See manual for addition...

Page 5: ...issions Emissons on Low Outside Air Size 525 Lbs 6 inch 18 in 20 in Max 1 500 3000 sq ft 1 1 Grams Per Hr 0 8 Grams Per Hr 3 or 4 inch SAFETY NOTICE IF THIS STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLLOW THE INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA 223 mm 583 mm 326 mm 6...

Page 6: ...6 Harman TL300 Specifications Andirons Grate Air Control Front Load Door Top Load Door Handle Ash Door Ash Door Latch Front Load Door Latch Top Load Door Top Load Opening ...

Page 7: ...d to rain or extremely damp conditions Hardwoods are favored because they are heavier and contain more heating capacity BTU s per load than do softwoods Wood should be split and stored under cover for seasoning a year is recommended Your stove is not an incinerator do not burn garbage painted or treated wood plastics or other debris Keep the area around the stove free from clutter Keep all combust...

Page 8: ... U S and 60 1524 mm in Canada Due to excessive heat build up at the wall passthrough using double wall pipe horizontal venting is only approved into a masonry chimney See Detailed Clearances on Page 9 Installation Mobile Home Installation The TL300 is approved for mobile home installations in the US only Mobile Home installation should be done in ac cordance with the Manufactured Home and Safety S...

Page 9: ...Only Top vent vented out back wall with 90o elbow Masonry Chim ney Only 21 15 11 2 28 Top vent ceiling and sidewall clearances 28 17 Single Wall Pipe Top Vent Parallel Installation 20 Double Wall Pipe Parallel Installation 18 27 27 18 Corner Installation with Single and Double Wall Pipe 18 5 13 28 17 15 21 775 mm 500 mm 375 mm 775 mm 50 mm 575 mm 425 mm 600 mm 450 mm 775 mm 500 mm 575 mm 425 mm 70...

Page 10: ...ize of the flue collar opening Do not use makeshift components No part of the chimney connector may pass through an attic or roof space closet or other concealed space or through a floor or ceiling Whenever possible avoid passing the connec tor through a combustible wall if you must use an approved wall pass through described later in this section Assemble the connector beginning at the flue colla...

Page 11: ...hest point at which they exit from the roof Then the chimney must extend 2 ft 6 m above the highest point within a 10 ft 3 m radius Thus the 3 foot 2 foot 10 foot rule 3ft Above roof exit point 2ft Higher than anything within 10ft of the chimney NOTE The restriction of not venting more than one appliance to the same flue applies to the U S specifically While it is not recommended that you use the ...

Page 12: ...pe is a piece of steel pipe used the same way In Canada a breech pipe has ridges or protrusions to lock it firmly into the refractory cement In either case the chimney connector vents to the chimney through the thimble or breech pipe Using a thimble the connector slides completely inside the masonry to the inner edge of the flue liner and may be eas ily removed for chimney and connector inspection...

Page 13: ...Harman TL300 13 Venting Standard Ceiling Installation with Factory Built Chimney Cathedral Ceiling Installation with Factory Built Chimney ...

Page 14: ... Minimum of three Sheet Metal Screws per Joint of Chimney Connector Mantel and Trim Protection Floor Protection in Accordance with Solid Fuel Appliance Listing Airtight insulated Clean out Chimney Breach Fireplace Conversion with Non Combustible Wall Floor Protection Combustible Floor Damper Closed and Sealed with Non Combus tible Material ...

Page 15: ...sembly 1 Clearance for Exterior Chimney or 2 Clearance for Interior Chimney and 2 Clearance for NFPA 211 Type Approved Thimbles Floor Protecion in Accordance with Solid Fuel Appliance Listing Check with your local building codes for clearance Combustible Wall Sheetrock Airtight insulated Clean out Combustible Floor Floor Protection 15 Damper Closed and Sealed with Noncombustible Material Mantel Tr...

Page 16: ... burned This represents most of the wood s heating capacity The final stage is the charcoal stage where the charcoal burns the remaining heat content out of the fuel Ash re mains after the burning is complete Within the primary firebox two or more of these stages of combustion are occurring simultaneously Operation The Combustion Process Two important controls the top load door handle and the air ...

Page 17: ...do not have the proper coal bed Open the bypass damper and continue with the process until a significant coal bed is formed To regulate the speed of the optional convection blower adjust the variable speed control from low to high by turning the knob located on the blower The blower speed should be matched to the air control lever setting When the air setting is low the blower should always be at ...

Page 18: ...r until all cinders have thoroughly cooled This could take days Never use the ash disposal container for other trash Wood ash can be added to your garden or compost g Building and Maintaining the Fire Cont As you begin to operate your stove at higher tem peratures you will notice a hot or unpleasant smell this is just the paint going through the curing process and will disappear after a few fires ...

Page 19: ... The inside of the fire chamber should be examined for damage to the refractory lining material grates and casting If any bricks have been damaged replace them with Harman replacement parts NOTE Be sure not to insert anything such as a fire poker into the Combustion Package Doing this may cause severe damage to the combustion package See below Glass Replacement If the stove s glass is cracked or b...

Page 20: ...ut the added ramp tension needed to keep the damper held in the closed position To adjust the ramp the stove MUST be allowed to go out and cool down After the stove has cooled off remove the stove pipe from the stove collar and close the damper Using a flashlight look into the collar About mid point of the damper plate on the backside you will see the adjustment bolt for the ramp tension See figur...

Page 21: ...tional The TL300 is designed to accommodate the use of outside air introduced directly to the stove The opening is located at the back of the stove pedestal base You ll notice there is a rounded hole with the etching of a larger hole The size needed depends on the length of pipe be ing used see below Check with your local building inspector to find out requirements determining if outside air is ne...

Page 22: ... list on following page Wood Stove 1 90 06900 1 black 1 90 06900 2 charcoal 1 90 06900 3 goldenfire 1 90 06900 4 Metallic blue 1 90 06900 5 honey glo 1 90 06900 10 Mojave red 1 90 06900 12 Forest green beginning Manufacturing date aug 2007 ending Manufacturing date active ...

Page 23: ...2 req 3 31 08724 Gasket Top Load Door 1 00 10050 Y Hinge Spacer Qty 2 req 2 00 40021L Lid Hinge Set Bottom 1 00 40022 Y 8 Left Side Shield 2 00 06926P Y 9 Andrion and Andiron Extensions 2 00 05222 1 Y Screw 5 16 18 x 3 4 Grade 5 Zinc Plated Hex Cap Pkg of 100 3 30 1125 100 Y Washer 5 16 Zinc Plated USS Flat Pkg of 100 3 30 0204 100 Y 10 Front Load Door Assembly 1 10 06920A Door Latch 1 00 249119 Y...

Page 24: ... 2 Wooden Knob 3 40 06956 Y 18 3 Damper Linkage Arm Weldment Includes knob cap 1 10 06937W Y 18 4 Damper Pivot Gear Pkg of 2 2 00 06924 2 18 5 Damper Idler Gear 2 00 06923L Y 18 6 Damper Arm Gear Weldment 1 10 06916W Y 18 7 Damper Shaft Cover Weldment 1 10 06918W 18 8 Damper Linkage Weldment 1 10 249146 Y Hardware Package Includes Drive Arm Washer Pusher Block Bushing Wave Washer Screws 1 00 06901...

Page 25: ...et Brick Left 3 40 00103 Y 19 6 Side Brick Bracket Pkg of 2 1 00 06945 Y 19 7 Fire Brick 6 x 12 Qty 4 req Pre 551 4 40 86125 Y Post 551 3 40 86125 Y 19 8 Brick Insulation Qty 2 req 3 40 06944 Y 19 9 Grate 2 00 06925B Y 19 10 Inlet Brick Right 3 40 00104 Y 19 11 Right Inside Plate Assembly 1 10 249118A Y 19 12 Shoe Brick Gasket 3 44 06951 Y 19 13 Shoe Brick 3 40 00100 Y Harman Gold Label Pkg of 5 3...

Page 26: ...26 Harman TL300 This page intentionally left blank ...

Page 27: ......

Page 28: ......

Page 29: ...Harman TL300 29 Notes ...

Page 30: ...30 Harman TL300 Notes ...

Page 31: ......

Page 32: ...Proudly Printed On 100 Recycled Paper ...

Reviews: