Room Heater Pellet Fuel-Burning Type

SUITABLE FOR MOBILE-HOME INSTALLATION

This pellet burning appliance has been tested and listed for use In

Manufactured Homes In accordance with OAR 814-23-900 through 814-23-909

352 Mountain House Road, Halifax, PA 17032    (é.-U.)

US ENVIRONMENTAL PROTECTION AGENCY

Certified to comply with 2015 particulate emission standards. Not approved for sale after May 15, 2020.

Certifié conforme aux normes 2015 d’émission de particules. Non approuvé pour la vente après le 15 mai 2020.

Rev B

Test to/testé à ASTM E 1509-12, ULC-S627-00, 

EPA Method 28 & 5G

Room Heater, Pellet Fuel-Burning Type, Also For 

Use In Mobile Homes. (UM) 84-HUD

“PREVENT HOUSE FIRES”

 Install and use only 

in accordance with manufactures installation and 

operation instructions.

Contact  local  building  or  fire  officials  about 

restrictions and installation inspection in your 

area.

WARNING: FOR MANUFACTURED HOMES:

 

Do not install appliance in a sleeping room. An 

outside combustion air inlet must be provided. 

The structural integrity of the manufactured home 

floor, ceiling and walls must be maintained.

Refer to manufacturer’s instructions and local 

codes for precautions required for passing 

chimney through a combustible wall or ceiling. 

Inspect and clean exhaust venting system 

frequently in accordance with manufacturer’s 

instructions.

Use a 3” or 4” diameter type “L” or “PL” venting 

system.

Do  not  connect  this  unit  to  a  chimney  flue 

servicing another appliance.

Do not obstruct the space beneath the heater.

FOR USE WITH PELLETIZED WOOD FUEL 

ONLY.

EPA Certified Emissions: 1.8 g/hr

Input Rating Max: 5.0 lb. fuel/hr

Electrical  Rating: 240 VAC, 50 Hz, Start 1.75 

AMPS, Run 1.25 AMPS

U.S. Electrical Rating: 115 VAC, 60 Hz, Start 3.5 

AMPS, Run 2.5 AMPS

Fuel Type: Wood Pellet ONLY

Route power cord away from unit.

OPERATE ONLY WITH DOORS CLOSED

ThIs area musT 

be black

6"

2"

6.25"

6.25"

A

A

C

B

USA

CAN

MINIMUM CLEARANCES TO

COMBUSTIBLES

Back Wall to Appliance 

2”

Side Wall to Appliance  

6"

Corner Installation

Walls to Appliance 

6.25”

Use  a  non-combustible  floor  protector 

extending under and to the sides, front 

and  back  of  the  unit  as  shown  in  floor 

protection diagram. Measure front 

distance from the surface of the glass 

door.

Recommended: 

Non-combustible 

floor  protection  extended  beneath 

the  flue  pipe  when  installed  with 

horizontal venting.

Floor Protection*

 

USA 

CANADA

Sides   (A)  6” 

200 mm

Back    (B)  1” 

25 mm

Front*  (C)  6” 

450 mm

*Measured  From  Glass  in  the  USA 

ONLY

Alcove Installation

Min. Alcove Height          42”    (1067mm) 

Max. Alcove Depth          24”   (610mm)

Report #/Rapport #135-S-32-2

Modèle: ABSOLUTE43

Appareil de chauffage à granulés de bois

CONçU POUR MAISONS MOBILES

DANGER:

 Risque d’électrocution. Coupez 

l’alimentation électrique avant l’entretien. 

Remplacer le verre avec 5 mm miroir verre 

céramique de la même qualité disponible auprès de 

votre revendeur. 

En tenant la porte d’entrée et le couvercle de la trémie 

hermétiquement fermé pendant le fonctionnement de 

l’appareil

DISTANCES DE SECURITE PAR RAPPORT AUX 

MATERIAUX COMBUSTIBLES

Paroi arrière à l’appareil 

     51 mm

paroi latérale de l’appareil 

     152 mm

Installation en angle

Entre murs et apparell 

     159 mm

Installation en alcôve

Hauter minimale de l’alcôve       153 mm

Parois latérales de l’alcôve       915 mm

Profondeur maximale de l’alcôve     915 mm

PROTECTION dU SOL*

Côtés  (A)  200 mm

Arrière (B)  25 mm

Avant  (C)  450 mm

Utiliser une protection de sol non combustible sous 

l’appereil qui s’étend sur les côtes, l’avant et l’arrière 

du poêle (voir schéma). Pour la distance à l’avant, 

mesurer à partir de la surface de la porte en verre.

ll est recommendé que la protection s’étende jusque 

sous le conduit en cas d’installation d’un conduit 

horizontal ou sous le té en cas conduit vertical.

do  not  remove  this  label/Ne  pas  enlever  cette 

étiquette.Made in the USA/Fabriqué aux 

é.-U.

3-90-777

dANGER: Risk of electrical shock. disconnect power supply before servicing.

Replace glass only with 5mm ceramic available from your dealer.

For further instruction refer to owner’s manual.

Keep viewing and ash removal doors tightly closed during operation.

Test pour / tested à la norme ASTM E 1509 à 1512, 

ULC-S627-00, CSA B415.1-10, Méthode EPA 28 et 5G

Chauffe-chambre, Pellet à combustibles Type, également pour 

les maisons mobiles. (UM) 84-HUD

"Empêcher  MAISON  incendies" Installer et utiliser 

uniquement en conformité avec les instructions du fabricant 

d'installation et d'exploitation.

Contactez le service des incendies à propos des restrictions et 

l'inspection d'installation dans votre région.

AVERTISSEMENT: POUR maisons préfabriquées: Ne pas 

installer l'appareil dans une chambre à coucher. Une entrée 

d'air de combustion à l'extérieur doit être fournie. L'intégrité 

structurale de la maison étage, plafond et murs fabriqués doit 

être maintenue.

Reportez-vous aux instructions du fabricant et les codes 

locaux pour les précautions nécessaires pour faire passer 

la cheminée à travers un mur ou un plafond combustible. 

Inspectez et nettoyez système d'évacuation souvent en 

conformité avec les instructions du fabricant.

Utilisez un "ou 4" Type de diamètre «L» 3 ou le système de 

ventilation "PL".

Ne pas connecter cet appareil à un conduit de cheminée 

desservant un autre appareil.

Ne pas obstruer l'espace sous le chauffe-eau.

À UTILISER AVEC LA GRANULE dE BOIS SEULEMENT.

Émissions certifiés EPA: 1,8 g / h

Entrée Max Note:

 £ 5,0 carburant / h

Note  électrique: 240 VAC, 50 Hz, Lancer 1,75 AMPS, 

Exécuter 1,25 AMPS

US Note électrique: 115 VAC, 60 Hz, 3,5 AMPS Démarrer, 

Exécuter 2,5 AMPS

Type de carburant: Bois Pellet SEULEMENT

Route cordon électrique de l'appareil.

Fonctionner uniquement avec les portes fermées

date of Manufacture / date de fabrication:

2015   2016   2017   JAN   FEB   MAR   APR   MAY   JUN   JUL   AUG   SEP   OCT   NOV   DEC

Manufactured by / Fabriqué par: Hearth and Home Technologies 352 Mountain House Road, Halifax PA 17032

Congratulations

, The Harman

®

 Absolute43 pellet stove you 

have selected is designed to provide the utmost in safety, 

reliability, and efficiency.

As the owner of a new pellet stove, you’ll want to read and 

carefully follow all of the instructions contained in this owner’s 

manual. Pay special attention to all cautions and warnings.

This owner’s manual

 

should be retained for future reference. 

We suggest that you keep it with your other important 

documents and product manuals.
Your new Harman

®

 Absolute43 Freestanding Pellet Stove will 

give you years of durable use and trouble-free enjoyment. 

Welcome to the Harman

®

 family!

Read this manual before operating this appliance. 

Please retain this Owner’s Manual for future reference.

Read the Installation Manual before making any installation or finishing changes.

Listing Label Information/Location

The model information regarding your specific stove can be found on the 

rating plate usually located in the control area of the stove.

Model Name

Serial Number

EXAMPLE

Summary of Contents for Absolute43

Page 1: ...as stove Alertchildrenandadultstohazardsofhightemperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away HOT...

Page 2: ...el appareil 152mm Installationenangle Entremursetapparell 159mm Installationenalc ve Hauterminimaledel alc ve 153mm Paroislat ralesdel alc ve 915mm Profondeurmaximaledel alc ve 915mm PROTECTION dU SOL...

Page 3: ...3 Reference Materials A Service Parts 14 B Limited Lifetime Warranty 19 C Loss of Power Addendum 21 D Emergency Manual Ignition 21 E Troubleshooting 22 F Contact Information 24 1 Product Specification...

Page 4: ...and data collected during EPA emissions test A range of BTU outputs based on EPA default efficiency and the burn rates from the low and high EPA tests Based on the maximum feed rate per hour multipli...

Page 5: ...le safety gate Never leave children alone near a hot stove whether operating or cooling down Teach children to NEVER touch the stove Consider not using the stove when children will be present Use only...

Page 6: ...nce Before using the appliance have the venting system thoroughly inspected and replace any damaged components With any hearth appliance installation of smoke detectors is recommended on every level o...

Page 7: ...will void your warranty CAUTION Do not burn fuel that contains an additive May cause hopper fire Damage to product may result Read the list of ingredients on the packaging WARNING Tested and approved...

Page 8: ...5 ___ 07 15 8 3 90 777000c H Quick Start Guide 2 Fill hopper with pellets 3 Adjust arrows to set room desired temperature 4 Touch the On Off Power Icon Refer to Touch Manual for all other operations I...

Page 9: ...tall flames with black tails and is lazy The feed rate needs to be reduced or the burnpot needs cleaning Heat exchanger or exhaust blower needs cleaning Smoky start up or puffs of smoke from the airw...

Page 10: ...If you did not fill hopper The message will disappear in 30 seconds Replace the 2 AA batteries in the Wireless Remote Sensor If Wireless Remote Sensor batteries die the Back Up Sensor will continue t...

Page 11: ...l types OR X Venting System More frequently depending on the fuel type OR X 2 Maintenance Service When properly maintained your stove will give you many years of trouble free service Contact your deal...

Page 12: ...r handle to gain access to igniter element and cradle Figure 2 2 Using the brush supplied brush the igniter element free of any ash or debris Figure 2 2 The burnpot grate can be removed if needed Figu...

Page 13: ...ssary to clean accumulated ash from the glass surface allowing this ash to remain on the glass for long periods canresultin etching duetotheacidityoftheash Nevercleanthe glass while it is hot and do n...

Page 14: ...Material Service Parts Absolute 43 Beginning Manufacturing Date March 2015 Ending Manufacturing Date Active Part number list on following page Pellet Stove 06 15 1 90 777000 1 Black 1 90 777000 14 Maj...

Page 15: ...Pkg of 100 3 31 94807 100 5 Hopper Lid Hinge w Hardware 1 00 777771 Y Hopper Lid Hinge Pin Plates w Hardware 1 Set 1 00 777560 6 Cast Top Black 4 00 247236S Majolica Brown 1 00 247236 14 7 Hopper Ass...

Page 16: ...1 00 77723 Y 16 Ash Pan 1 10 777604A Y 17 Burn Pot Assembly 17 1 Burn Pot Weldment 1 10 777801A Y Gasket 3 44 724114 Y 17 2 Swing Plate Flame Guide 1 Set 1 00 777818 Y 17 3 Igniter w Bracket 1 00 777...

Page 17: ...h 3 20 6866 Y Tubing 1 8 Silicone 5 Feet 1 00 5113574 Y 30 Rear Cover Right 1 00 777613 Y 31 Feeder Assembly 31 1 Feeder Body 1 10 777513A Y 31 2 Slide Plate Assembly 1 10 777690A Y 31 3 Feed Cover Ga...

Page 18: ...when requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 5A Ceramic Fuse Pkg of 5 1 00 05237 Y Communication Cable 3 20 72662 Y Draft Meter...

Page 19: ...of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichev...

Page 20: ...NS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur Thi...

Page 21: ...ce the fire is out the ESP temperature will not rise The unit will then shut down and may flash a six blink status error See ESP error codes If the fire is still burning it will resume normal operatio...

Page 22: ...has failed Partially burned pellets Feed rate too high Poor air to fuel mixture Check burn pot clean out cover and air intake Burn pot may need to be cleaned Combination of all the above Smoke smell S...

Page 23: ...Harman Absolute43 Owner s Manual_R5 2015 ___ 07 15 23 3 90 777000c...