Harman®  •  Absolute43 Installation Manual_R2  •  2015 - ___ •  03/15

22

3-90-00778i

Appliance Set-Up 

 

Figure 5.1

Shipping Bolts (4)

(2) Bolts are located on both the 

left and right hand side.

A. Unpacking

The Absolute43 is bolted (1/4 x 1" hex head bolts) to the skid 

to prevent movement during shipping. 
To free the stove from the skid you must remove the hold-

down bolts from both the left and right hand side shipping 

brackets using a 7/16” socket or wrench. Figure 5.1.

B. Firebox Draft and Combustion Fan RPM

These units are pre-tested at the factory with exactly 120 

VAC,  60  Hz. They  are  checked  and  adjusted  for  firebox 

tightness,  gasket  leakage,  motor  operation  and  igniter 

operation. The Absolute43 is then factory set at a mid-point 

adjustment and in most cases will not need any adjustments.
Check and record the firebox draft before installing venting 

and after venting is installed 

(before starting fire)

.

There is a draft meter port located behind the left front leg 

just above the ash door latch. Install the magnahelic meter 

(capable of at least .5” of water column) 

Figure 5.2.

Plug unit into a 120 VAC, 60 Hz outlet.
Go to the “Home Screen”, the power icon should be gray. 

Press menu, on the first menu page press “test”.
The test page has 4 component test modes. The second icon 

is for the combustion fan test.
One press of the icon turns the combustion fan to full line 

voltage. 

(Note: During this test , the combustion fan will 

not achieve its top RPM of 3200 due to the density of the 

ambient air.)

 All RPM displays could vary +/- 50 from that 

of the set RPM’s. Allow several minutes for the fan motor to 

warm up.
Press the icon a second time, the combustion fan will go 

to “Maximum” (as set in the 

Authorized Dealer Only

 area 

under the combustion fan icon)
The “Maximum” is factory set at 2900 RPM. Allow the RPM 

to stabilize and record the firebox draft Maximum.
 

Before Install: __________ IWC

 

After Install: __________ IWC

(Firebox Draft and Combustion Fan rpM Cont.)

Press the icon a third time, the combustion fan will go to 

“Minimum”  (as  set  in  the 

Authorized Dealer Only

  area 

under the combustion fan icon) allow the RPM to stabilize 

and record the firebox draft minimum.
 

Before Install: __________ IWC

 

After Install: __________ IWC

Cold Stove Draft:

2500 RPM 

Low -.20 and -.25

2900 RPM 

High -.45 and -.50

Leaving  the  test  page  will  end  any  tests  in  progress  and 

goes back to whatever mode of operation it was set to on 

the home page.
If the unit is not adjusted properly, it does not cause a safety 

concern. If the unit is adjusted too high, only efficiency is lost. 

If the unit is adjusted too low, the low draft pressure switch 

will not allow the feed motor or the igniter to operate.

Draft Meter Port location

Figure 5.2

Connect the power cord to a 120 VAC, 60Hz grounded receptacle. (A surge 

protector is recommended to protect the circuit board.) Also be sure that the polarity 

of the outlet that the stove is plugged into is correct.

Summary of Contents for Absolute43

Page 1: ...ng codes prior to installation Installation MUST comply with local regional state and national codes and regulations Contact local building or fire officials about restrictions and installation inspec...

Page 2: ...n 9 4 Termination Location and Vent Information A Vent Termination Minimum Clearances 10 14 B Chimney Diagram 15 C Venting Use of Elbows 16 17 D Outside Air 18 E Locating Your Appliance and Chimney 19...

Page 3: ...wall roof flashing installed and sealed ________________________________ Terminations installed and sealed ________________________________ Electrical Section 1 Pg 4 120VAC unswitched power provided t...

Page 4: ...ault efficiency and the burn rates from the low and high EPA tests Based on the maximum feed rate per hour multiplied by approximately 8600 BTU s which is the average BTU s from a pound of pellets E E...

Page 5: ...Consult insurance carrier local building inspector fire officials or authorities having jurisdiction over restrictions installation inspection and permits It is a good idea to plan your installation o...

Page 6: ...any component not approved by Hearth Home Technologies Install parts or components not Listed or approved Disable safety switches Improper installation adjustment alteration service or maintenance can...

Page 7: ...anual_R2 2015 ___ 03 15 7 3 90 00778i 24 9 16 24 1 16 15 6 1 8 7 15 16 29 1 2 27 7 16 1 1 1 4 3 Clearances Figure 3 1 A Appliance Dimension Diagram Dimensions are actual appliance dimensions Use for r...

Page 8: ...safety but do not leave much room for access when cleaning or servicing Please take this into account when placing the stove Alternate floor protector dimension may be used as long as they satisfy th...

Page 9: ...low the smaller U S floor protection requirements ONLY if the user agrees to completely shut down the appliance and allow it to cool to where all fire is extinguished and the combustion blower and its...

Page 10: ...also provides excellent venting for normal operation but requires the stove to be installed farther from the wall The vertical portion of the vent should be three to five feet high and at least 1 from...

Page 11: ...xisting fireplace chimney Figure 4 4 This method provides excellent venting for normal operation This method also provides natural draft in the event of a power failure If the chimney condition is que...

Page 12: ...t vent pipe fittings Seal pipe joints with silicone or aluminum tape in addition to the sealing system used by the manufacturer Pipe size should be increased to 4 using this method 6 Installing into a...

Page 13: ...gure 4 9 Area within dotted circle represents the minimum clearance to combustible materials such as shrubbery mulch or tall grasses 12 min above ground level Minimum flue vent configuration It is rec...

Page 14: ...ay to the top of the chimney The chimney should be inspected and cleaned before installing your stove If you discover that the chimney does not have a clay tile liner or has cracks or flaking of the t...

Page 15: ...vertical clearance to a ventilated soffit located above the terminal within ahorizontal distance of2feet 60 cm fromthe center line of the terminal must be a minimum of 18 E The clearance to an unventi...

Page 16: ...ble horizontal venting length is 4 ft for 3 4 pellet vent pipe Example First Floor Installation A unit is to be installed using 3 Pellet Pipe with 3 feet of horizontal pipe a Tee 10 feet of vertical p...

Page 17: ...ude 10 Ft 15 Ft 20 Ft 25 Ft 30 Ft 5 Ft 0 Ft 15 Ft Equivalent Vent Length EVL Maximum Horizontal Run Long runs of flex or PL vent pipe installed directly vertical from the flue stub may require more fr...

Page 18: ...tion must be given to the total house demand House demand may consume some air needed for the stove especially during a power failure It may be necessary to add additional ventilation to the space in...

Page 19: ...s in the home are closed Record the second draft reading _______ If the second reading is more than 05 lower than the first reading check for possible restrictions or the need for outside air For more...

Page 20: ...a starting collar to attach the venting system to the stove The starting collar must be secured to the flue stub with at least three screws and sealed with high temp silicone caulking 4 stainless ste...

Page 21: ...intain regularly Conveniently locate a ClassAfire extinguisher to contend with small fires In the event of a hopper fire Evacuate the house immediately Notify fire department J Inspect Appliance Compo...

Page 22: ...l line voltage Note During this test the combustion fan will not achieve its top RPM of 3200 due to the density of the ambient air All RPM displays could vary 50 from that of the set RPM s Allow sever...

Page 23: ...m as the stove Clothing and other flammable materials should not be placed on or near this stove Installation and repair of this stove should be done by a qualified service person The appliance should...

Page 24: ...Harman Absolute43 Installation Manual_R2 2015 ___ 03 15 24 3 90 00778i B Wiring Diagram...

Page 25: ...Harman Absolute43 Installation Manual_R2 2015 ___ 03 15 25 3 90 00778i...

Page 26: ...in U S A Copyright 2015 Harman a brand of Hearth Home Technologies Inc 352 Mountain House Road Halifax PA 17032 www harmanstoves com Please contact your Harman dealer with any questions or concerns Fo...

Reviews: