Accentra 52i Pellet Insert Zero Clearance Cabinet
Part #1-00-574323
9
3”
12”
36”
12”
Min
Minimum Flue Configuration.
3” or 4” PL Vent Pipe
Clearance to shrubbery, grass,
or any other type plant
Minimum clearance of flue
outlet to ground level
Excessive mulch and or other types of combustible
bedding should be kept to a minimum directly
beneath the flue outlet area.
Combustible materials are allowed to
touch the outside of the ZC Cabinet.
PL Vent manufactures wall
pass-through.
NOTE:
When fiberglass insulation is placed
directly on top of the ZC Cabinet it should not touch
the vent pipe. The outer ring knockout of the flue
pipe opening is designed to install a standard 6”
sheetmetal starter collar and a short length of pipe
to keep the insulation from touching the vent pipe.
The finished face of the fireplace
facade, MUST be flush with the ZC
Cabinet front face when complete.
Rough-In Support Kit
Harman® #1-00-574246
Finished floor protection
Because of the weight of the Accentra 52i, if raised hearth
is framed, heavier framing and support should be utilized.
Suggested minimum of 2X6’s in 12” centers under the ZC
Cabinet and the hearth in front of the Cabinet.