background image

13

3-90-08326R35_11/14

Combustion Motor Speed Control Low draft only set 

point.

The small straight screwdriver slot is plastic; therefore, the 

unit can be adjusted while in operation.
These units are pre-tested at the factory with exactly 120 VAC, 

60 Hz. They are checked and adjusted  for firebox tightness, 

gasket leakage, motor operation and igniter operation.  The 

Accentra is then factory set at a high adjustment.

NOTE: low draft adjustment may be required. The 

factory low draft setting may not be correct for the units 

permanent installation conditions.

The control board on the Accentra is equipped with a low 

draft adjustment port.  Located on the control face just to 

the left of the igniter light. Fig. 15. This voltage adjustment 

is provided to allow the unit to be adjusted for the household 

voltage where the unit is going to be in permanent operation. 

NOTE: The line voltage varies from area to area and often 

home to home.
The low draft voltage should be adjusted to achieve the most 

efficient  burn  on  low  burn  or  "maintenance". This  voltage 

adjustment  allows  the  installer  to  change  the  low  voltage 

set point approximately 15 volts.  This adjustment should 

be done by the installer during set up because a draft meter 

reading is 

required 

to ensure proper set up.

If the unit is not  adjusted properly, it does not cause a safety 

concern. If the unit is adjusted too high, only efficiency is lost. 

If the unit is adjusted too low, the low draft pressure switch 

will not allow the feeder motor or the igniter to operate. 

A simple draft test should be performed after completing the 

flue pipe installation. Record the results for future reference:
1.  Plug unit into a 120 VAC, 60 Hz outlet.
2.  Close the hopper lid and front view door. Neither pellets 

or a fire are required for this test.

3.  With the mode selector in the "OFF" position, turn the feed 

adjuster to "TEST".

4.  Record  the  high  draft_____in.  W.C.  (Normal  is  -.45  to 

-.55) The control will be on the High Draft for a total of 1 

minute.

5.  After 1 minute, the combustion motor will go down to low 

draft  and  the  distribution  blower  will  go  on  high. Allow 

approximately  15  seconds  to  pass  for  the  combustion 

motor to slow before checking the low draft.

6.  If the low draft is between .30 and .35, record the reading 

_____ in. W.C.  If the reading is higher, slowly turn the 

set screw counter-clockwise until the draft lowers. If the 

reading is lower, very slowly turn the set screw clockwise 

until the draft increases.

NOTE: In some cases, the draft may not go as low as .30 

even with the set screw completely counter-clockwise.

Fig. 15

Fig. 16

low draft voltage Adjustment

The rear panel will need to be removed prior to installing the draft 
meter to the barbed tee Fig. 16. Be sure to hold the barbed tee while 
removing the plug cover. Replace plug cover after draft test.

MAGNEHELIC

INCHES OF WATER

0

.10

.20

.30

.40

.50

Summary of Contents for Accentra Freestanding Pellet Stove

Page 1: ...z votre concessionnaire de Harman Home HEATING Save these instructions Installation Operating Manual Model s Accentra Freestanding Pellet Stove NOTICE SAVE THESE INSTRUCTIONS Hot glass will cause burn...

Page 2: ...0 3 2 EN 61000 3 3 PREVENTION DES INCENDIES Respecter scrupuleusement les instructions du constructeur pour l installation et les consignes de fonctionnement Respecter les r gles de s curit en vigueur...

Page 3: ...nual With its specially designed burn pot and the Advance Igniter Automatic Ignition System the unit can burn a large variety of pelletized fuels with varying ash content The accordion style cast iron...

Page 4: ...lows you to choose between Room Temp Mode Stove Temp Mode or OFF Also allows you to vary the distribution blower speed by turning the knob to the high or low side of each mode Feed adjuster Sets the m...

Page 5: ...ficed for exact room temperature Therefore as it gets colder more pellets will be burned automatically The distribution blower speed will vary according to the position of the mode selector pointer an...

Page 6: ...box low pressure switch will not allow the auger motor or the igniter element to operate if the view door is open 4 Adjust Feed Rate If this is your first fire or you are trying different pellets set...

Page 7: ...operation with the temperature dial set at 4 or less the distribution fan will not operate A 3 on the temperature dial and a 4 on the feed adjuster is approximately 80 output The distribution blower...

Page 8: ...ning and then fill the hopper with pellets As the system works they will be burned 2 The TEST cycle will operate the feeder motor for exactly one minute Turning to TEST again and again may feed too mu...

Page 9: ...e firing side and at least 7 87 200mm on the other sides In Canada you may follow smaller U S floor protection requirements ONLY if the user agrees to completely shut down the appliance and allow it t...

Page 10: ...as far as shown in Fig 10 11 12 Clearances May Only be Reduced Using Methods Approved by the Regulating Authority Having Jurisdiction Note that the clearances shown are minimum for safety but do not l...

Page 11: ...bolt to a plate and the stove then sits on the plate The rubber leveling feet are removed to allow the stove to fit down over the leg plate The leg kit adds 2 95 inches in height The leg kit can also...

Page 12: ...turer s components to provide an effective vapor barrier where the chimney or other component penetrates to the exterior of the mobile home DO NOT MIX COMPONENTS FROM DIFFERENT MANUFACTURERS The top s...

Page 13: ...se a safety concern If the unit is adjusted too high only efficiency is lost If the unit is adjusted too low the low draft pressure switch will not allow the feeder motor or the igniter to operate A s...

Page 14: ...e installed even if only installed on the rear of the unit as a return air sensor There is an intake screen on the bottom of the rear sheet metal enclosure This is an ideal place to tie wrap the senso...

Page 15: ...o the unit Vent Pipe Pellet venting pipe also known as PL vent is constructed of two layers with air space between the layers This air space acts as an insulator and reduces the outside surface temper...

Page 16: ...ove especially during a power failure It may be necessary to add additional ventilation to the space in which the pellet appliance is located Consult with your local HVAC professional to determine the...

Page 17: ...lure Note Do not place joints within wall pass throughs Fig 20 Fig 21 3 Ft to Combustibles 3 Ft to Combustibles 3 Ft to Combustibles 3 Ft to Combustibles 2 Preferred method This method also provides e...

Page 18: ...his method can be used for normal operation This method also provides natural draft in the event of a power failure The damper area must be sealed with a steel plate not supplied Kaowool mineral wool...

Page 19: ...ddition to the sealing system used by the manufacturer Pipe size should be increased to 4 using this method THE chimney must be of a type suitable for solid fuel burning 6 Installing into an existing...

Page 20: ...t temperatures at least 3 feet away from the flue termination PL vent manufacturer s firestop spacer and support 1 MIN No insulation or other combustible materials are allowed within 3 of the PL vent...

Page 21: ...ulator I The clearance to service regulator vent outlet must be a minimum of 6 feet J The clearance to a non mechanical air supply inlet to the building or the combustion air inlet to any other applia...

Page 22: ...their customers The best time to have this cleaning performed is after the heating season If You Experience a Soot or Creosote Fire Turn the mode selector dial to the OFF position Allow the unit to sh...

Page 23: ...Remove the 2 5 16 wing nuts Slide the cover off of the threaded studs Inspect and clean the inner chamber if necessary See above picture Reinstall the cover making certain it is centered on the feede...

Page 24: ...combustion intake assembly is held into place with two swing latches Fig 32 Swing each latch until it hangs down away from the retainer stud Now the assembly can be taken out by tilting the right sid...

Page 25: ...s of the burn pot grate Simply push the allen wrench down through each hole ensuring it is clear of any build up paying attention not to damage the igniter element in the process Figure 36 The igniter...

Page 26: ...hts will remain on The Control Board ESP combination is responsible for all high limit safety control There are 2 high limits one normal operation high limit and one backup high limit The control has...

Page 27: ...over and air intake 3 Burn pot or heat exchanger tubes may need to be cleaned 4 Combination of all the above 5 6 status blink A6 blink control board status indication is caused by poor or incomplete c...

Page 28: ...properly through the feed system Tested and approved for use with wood pellets and a mixture of shelled field corn and wood pellets ONLY Burning of any other fuel will void your warranty NOTICE Heart...

Page 29: ...amp BTU Range 0 to 40 000 Feed Rate 75 lbs hr on minimum on maintenance 5 lbs hr on maximum Flue Size 3 inch Pellet Vent Pipe Maximum Wattage 440 Watts Start cycle and test Start Cycle Wattage 340 Wat...

Page 30: ...NECTIONS 1 3 2 WHITE PLUGGED BROWN 5 6 7 EMPTY WHITE WHITE WHITE 4 8 10 9 RED BLUE YELLOW PART NO 3 90 00877 BLACK 11 WHITE 11 PIN PLUG MALE FEMALE CONNECTIONS GREEN WIRE IS GROUND BONDED TO STOVE FRA...

Page 31: ...et temperature knob to desired amount Turn mode selector knob onto Room Temp mode After the fire has lit watch that the fuel does not feed too fast that it pushes the red glowing fuel bed off of the b...

Page 32: ...tinued operation Your appliance will recognize when power is restored What happens depends on ESP temperature and whether it is equipped with automatic ignition In Automatic setting units equipped wit...

Page 33: ...tion warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier Th...

Page 34: ...y does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw...

Page 35: ...15 1 10 247778A Post 008408015 1 10 247260A Y Gasket Hopper Throat 3 44 677185 Y Gasket Hopper Top 1 00 375501 Y Grommet 3 4 3 31 960021 Hopper Switch 48 Post 008403501 3 20 232108 Y Additional servic...

Page 36: ...Plunger Threaded Pkg of 3 3 31 5500 3 Hopper Lid Ball Spring Mount Bracket Pre 11340 2 00 247116 Hopper Lid Glass Assembly w Gasket Pre 11340 1 10 247100 Y Hopper Hinge Assembly Qty 2 req Pre 11340 1...

Page 37: ...2 Sets 1 00 00247 Y 22 Cast Door w Rope and Grill 1 10 247109A Door Rope 1 00 00888 Y 23 Cast Air Grill 3 00 247114 24 Door Glass 3 40 777000 Y Glass Rope 1 00 2312 Y 25 Glass Retainer Qty 2 req 2 00...

Page 38: ...77152 Y 37 6 Gear Motor 4 RPM 3 20 08752 Y 37 7 Sprocket Kit 1 00 06626 Y 37 8 Bracket Gear Motor 1 10 677005 Y Grommets Spacers Pkg fo 25 1 00 960026 37 9 3 4 Feeder Tensioner 3 31 00075 Y 37 10 3 1...

Page 39: ...0 06810A 38 5 Gasket Feeder Air Intake Pkg of 6 3 44 72224 6 Y 38 6 UL Feeder Air Intake 1 10 247239 38 7 Gasket Ultra Air Intake Pkg of 10 3 44 677160 10 Y 38 8 Ultra Feeder Weldment 1 10 724132 Y 38...

Page 40: ...35 Y Fuse 6 AMP Pkg of 5 3 20 49447 5 Y Gasket Base and Sides 5 Ft 1 00 37525 Y Gasket Burn Pot Tailpipe Pkg of 5 1 00 07381 Y Hopper Muffler Fittings 1 00 18186618 Y Hopper Switch Retrofit Kit 1 00 2...

Page 41: ...41 3 90 08326R35_11 14 Service Maintenance Log Date Of Service Performed By Description Of Service...

Page 42: ...42 3 90 08326R35_11 14 Service Maintenance Log Date Of Service Performed By Description Of Service...

Page 43: ......

Page 44: ...ting appliance boasts uncompromising attention to detail and helps preserve our planet by using environmentally responsible fuels Signature of Boxer Your premium quality hearth product designed and as...

Reviews: