8
Installation
Note:
Before installation, please ensure the device is disconnected from the power source.
Steps to install the device into
an equipment rack:
The DVX occupies two rack units in a standard equipment rack. The following steps apply to mounting the
DVX.
1.
Discharge any static electricity from your body by touching a grounded metal object.
2.
Position and install the mounting brackets, as shown in the following picture, using the supplied
mounting screws (the brackets are installed when you first open the box).
NOTE:
The left and right mounting brackets are not identical. Please install in the orientation shown.
Brackets attach at the side
toward the f ront of the unit
3.
Install the DVX in the mounting rack by using the mounting screws to affix the unit to the rack.
4.
Connect any applicable wires to the DVX.
CAUTION: DO NOT stand other units directly on top of the DVX when it is rack mounted, as this will place
excessive strain on the mounting brackets.
Ventilation
ALWAYS ensure that the rack enclosure is adequately ventilated. Do not block any ventilation openings.
Sufficient airflow must be achieved (by convection or forced-air cooling) to satisfy the ventilation
requirements of all the items of equipment installed within the rack.
NOTE: The maximum operating ambient temperature is 40°C (104°F).
CAUTION: When installing equipment into a rack, distribute the units evenly. Otherwise, hazardous
conditions may be created by an uneven weight distribution.
Reliable earthing (grounding) of rack-mounted equipment should be maintained.
The DVX should not be installed in enclosed spaces. It is recommended that you leave 1 RU of space above
the DVX when you install it in a rack.