background image

© 2015 Harman. All rights reserved. Modero, AMX, AV FOR AN IT WORLD, and HARMAN, and their respective logos are registered trademarks of 

HARMAN. Oracle, Java and any other company or brand name referenced may be trademarks/registered trademarks of their respective 

companies.
AMX does not assume responsibility for errors or omissions. AMX also reserves the right to alter specifications without prior notice at any time.
The AMX Warranty and Return Policy and related documents can be viewed/downloaded at www.amx.com.

3000 RESEARCH DRIVE, RICHARDSON, TX 75082 AMX.com | 800.222.0193 | 469.624.8000 | +1.469.624.7400 | fax 469.624.7153
AMX (UK) LTD, AMX by HARMAN - Auster Road, Clifton Moor, York, YO30 4GD United Kingdom • +44 1904-343-100 • www.amx.com/eu/

 93-2265-06  REV: H

Last Revised: 6/22/2015

Accessing the Connection & Networks Page

1.

From the Settings menu, select 

Connection & Networks

. If the page is password 

protected, this opens a password keypad.

2.

Enter the panel password into the keypad (the default is 

1988)

 and select 

OK

 to 

access the page (FIG. 5).

Configuring the Panel’s IP Address

The first step is to configure the panel’s communication parameters. This only 

configures the panel to communicate with a network, and it is still necessary to tell the 

panel with which Master it should be communicating.

Network Communication With a DHCP Address

In the 

Connection & Networks

 page:

1.

Select 

Network Connection

 to open the 

Network Connection 

page (FIG. 6). 

2.

Toggle the 

DHCP/Static

 field until the choice cycles to 

DHCP

. This action causes all 

fields on the page (other than 

Host Name

) to be disabled.

3.

Select 

Host Name

 to open the Host Name keyboard. Enter the new host name and 

click 

OK

.

Setting Static IP Information

When using 

DHCP

 settings for a panel, the DHCP server will automatically populate 

almost all of the 

Network Connections

 page fields, with the exception of 

Hostname

When setting the panel for 

Static

, however, this information must be entered manually. 

To enter the network connection information:

1.

In 

DHCP/Static

, press the field until the entry reads “Static”. This enables all of 

the editable 

Network Connections

 page fields.

2.

Select the 

IP Address

 field to open the 

Wired IP Address

 keypad (FIG. 7).

3.

Enter the server’s IP address and click 

OK

.

4.

Repeat this procedure with the other fields on the 

Network Connections

 page.

5.

When finished, the new connection information will be visible in the 

Network 

Connections 

page.

Connecting to a NetLinx Master

To establish the type of connection to make between the panel and NetLinx Master:

1.

In the 

Connection & Networks

 page, select 

Master Connection

 to open the 

Master 

Connection

 page (FIG. 8).

2.

Press 

Mode

 to toggle through the available connection modes (

Auto

URL

 or 

Listen

):

 

3.

If you have enabled password security on your Master, you need to set the 

username and password within the device.
a. Select 

Username 

to open the Master User keyboard.

b. Set your Username and select 

OK

.

c. Select the 

Password

 to open the Master Password keyboard.

d. Set your Master Password and select 

OK

.

e. Press the 

Back

 button twice to return to the 

Settings

 page.

Related Software and Additional Documentation (at www.amx.com)

• Programming the Modero S Series touch panels requires the use of the latest 

versions of NetLinx Studio and TPDesign4, both available to download at 

www.amx.com. Refer to the NetLinx Studio and TPDesign4 online help for 

information.

• For additional information on the MST-701 panel, refer to the 

S-Series Touch 

Panels MSD/T-1001, MSD/T-701 & MSD/T-431 Instruction Manual.

• For detailed information on the Settings menu as well programming information 

and instructions on upgrading firmware, refer to the 

Modero S Series 

Programming Guide

.

FIG. 5  

CONNECTION & NETWORKS PAGE

FIG. 6  

NETWORK CONNECTION PAGE

FIG. 7  

WIRED IP ADDRESS KEYBOARD

FIG. 8  

MASTER CONNECTION PAGE

CONNECTION MODES

Mode Description

Procedures

URL

The device connects to the 

target Master’s IP address 

via a TCP connection.

1) Select 

URL

 in the 

Mode

 menu.

2) Enter the 

Master IP/URL

Master Port 

Number

, and 

Username

/

Password

 (if 

required by the Master).

Press 

OK

 to save changes.

Listen This mode allows the panel 

to “listen” for the Master’s 

communication signals. 
Note that in this mode, the 

System Number

 and 

Master 

IP/URL

 fields are read-only.

1) Select 

Listen

 in the 

Mode

 menu.

2) Confirm the panel’s IP address is on the 

Master’s URL list (via NetLinx Studio).

3) Press 

OK

 to save changes.

Note: The Host Name can be used to locate the 

panel on the Master (particularly useful for 

DHCP connections where the IP address can 

change).

Auto

Use this mode when both 

the panel and the NetLinx 

Master are on the same 

Subnet.

1) Select 

Auto

 in the 

Mode

 menu.

2) Enter the System Number and Username 

and Password (if applicable). 

3) Press 

OK

 to save changes.

Reviews: