© 2015 Harman. All rights reserved. Modero, AMX, AV FOR AN IT WORLD, and HARMAN, and their respective logos are registered trademarks of
HARMAN. Oracle, Java and any other company or brand name referenced may be trademarks/registered trademarks of their respective
companies.
AMX does not assume responsibility for errors or omissions. AMX also reserves the right to alter specifications without prior notice at any time.
The AMX Warranty and Return Policy and related documents can be viewed/downloaded at www.amx.com.
3000 RESEARCH DRIVE, RICHARDSON, TX 75082 AMX.com | 800.222.0193 | 469.624.8000 | +1.469.624.7400 | fax 469.624.7153
AMX (UK) LTD, AMX by HARMAN - Auster Road, Clifton Moor, York, YO30 4GD United Kingdom • +44 1904-343-100 • www.amx.com/eu/
93-2265-06 REV: H
Last Revised: 6/22/2015
Accessing the Connection & Networks Page
1.
From the Settings menu, select
Connection & Networks
. If the page is password
protected, this opens a password keypad.
2.
Enter the panel password into the keypad (the default is
1988)
and select
OK
to
access the page (FIG. 5).
Configuring the Panel’s IP Address
The first step is to configure the panel’s communication parameters. This only
configures the panel to communicate with a network, and it is still necessary to tell the
panel with which Master it should be communicating.
Network Communication With a DHCP Address
In the
Connection & Networks
page:
1.
Select
Network Connection
to open the
Network Connection
page (FIG. 6).
2.
Toggle the
DHCP/Static
field until the choice cycles to
DHCP
. This action causes all
fields on the page (other than
Host Name
) to be disabled.
3.
Select
Host Name
to open the Host Name keyboard. Enter the new host name and
click
OK
.
Setting Static IP Information
When using
DHCP
settings for a panel, the DHCP server will automatically populate
almost all of the
Network Connections
page fields, with the exception of
Hostname
.
When setting the panel for
Static
, however, this information must be entered manually.
To enter the network connection information:
1.
In
DHCP/Static
, press the field until the entry reads “Static”. This enables all of
the editable
Network Connections
page fields.
2.
Select the
IP Address
field to open the
Wired IP Address
keypad (FIG. 7).
3.
Enter the server’s IP address and click
OK
.
4.
Repeat this procedure with the other fields on the
Network Connections
page.
5.
When finished, the new connection information will be visible in the
Network
Connections
page.
Connecting to a NetLinx Master
To establish the type of connection to make between the panel and NetLinx Master:
1.
In the
Connection & Networks
page, select
Master Connection
to open the
Master
Connection
page (FIG. 8).
2.
Press
Mode
to toggle through the available connection modes (
Auto
,
URL
or
Listen
):
3.
If you have enabled password security on your Master, you need to set the
username and password within the device.
a. Select
Username
to open the Master User keyboard.
b. Set your Username and select
OK
.
c. Select the
Password
to open the Master Password keyboard.
d. Set your Master Password and select
OK
.
e. Press the
Back
button twice to return to the
Settings
page.
Related Software and Additional Documentation (at www.amx.com)
• Programming the Modero S Series touch panels requires the use of the latest
versions of NetLinx Studio and TPDesign4, both available to download at
www.amx.com. Refer to the NetLinx Studio and TPDesign4 online help for
information.
• For additional information on the MST-701 panel, refer to the
S-Series Touch
Panels MSD/T-1001, MSD/T-701 & MSD/T-431 Instruction Manual.
• For detailed information on the Settings menu as well programming information
and instructions on upgrading firmware, refer to the
Modero S Series
Programming Guide
.
FIG. 5
CONNECTION & NETWORKS PAGE
FIG. 6
NETWORK CONNECTION PAGE
FIG. 7
WIRED IP ADDRESS KEYBOARD
FIG. 8
MASTER CONNECTION PAGE
CONNECTION MODES
Mode Description
Procedures
URL
The device connects to the
target Master’s IP address
via a TCP connection.
1) Select
URL
in the
Mode
menu.
2) Enter the
Master IP/URL
,
Master Port
Number
, and
Username
/
Password
(if
required by the Master).
Press
OK
to save changes.
Listen This mode allows the panel
to “listen” for the Master’s
communication signals.
Note that in this mode, the
System Number
and
Master
IP/URL
fields are read-only.
1) Select
Listen
in the
Mode
menu.
2) Confirm the panel’s IP address is on the
Master’s URL list (via NetLinx Studio).
3) Press
OK
to save changes.
Note: The Host Name can be used to locate the
panel on the Master (particularly useful for
DHCP connections where the IP address can
change).
Auto
Use this mode when both
the panel and the NetLinx
Master are on the same
Subnet.
1) Select
Auto
in the
Mode
menu.
2) Enter the System Number and Username
and Password (if applicable).
3) Press
OK
to save changes.