background image

pg. 7

 

 

EU COMPLIANCE INFORMATION:

 

 

Hereby, Harman Professional, Inc. declares that the equipment type MU-1000/1300/2300/3300

 

is in compliance with the 

following: European Union Low Voltage Directive 2014/35/EU; European Union EMC Directive 2014/30/EU; European 

Union Restriction of Hazardous Substances Recast (RoHS2) Directive 2011/65/EU and as amended by 2015/863;  

 

The full text of the EU declaration of conformity is available at the following internet address: 

https://www.amx.com/en/support_downloads/download_types/certification

 

 

WEEE NOTICE: 

 

The WEEE Directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE), which entered into force as 

European law on 14/02/2014, resulted in a major change in the treatment of electrical equipment at end-of-life. 

 

The purpose of this Directive is, as a first priority, the prevention of WEEE, and in addition, to promote the reuse, recycling 

and other forms of recovery of such wastes so as to reduce disposal. The WEEE logo on the product or on its box 

indicating collection for electrical and electronic equipment consists of the crossed-out wheeled bin, as shown below. 

 

 

 

 

 

 

 

 

This product must not be disposed of or dumped with your other household waste. You are liable of dispose of all your 

electronic or electrical waste equipment by relocating over to the specified collection point for recycling of such hazardous 

waste. Isolated collection and proper recovery of your electronic and electrical waste equipment at the time of disposal will 

allow us to help conserving natural resources. Moreover, proper recycling of the electronic and electrical waste equipment 

will ensure safety of human health and environment. For more information about electronica and electrical waste 

equipment disposal, recovery, and collection points, please contact your local city center, household waste disposal 

service, shop from where you purchased the equipment, or manufacturer of the equipment.  

 
Manufacturer Information: 

HARMAN Professional, Inc. 

Address: 8500 Balboa Blvd. Northridge, CA 91329 USA 

 

EU Regulatory Contact: 

Harman Professional Denmark ApS 

Olof Palmes Allé 44, 8200 Aarhus N, Denmark 

UK Regulatory Contact: 

Harman Professional Solutions 

2 Westside, London Road, Apsley, Hemel Hempstead, HP3 9TD, UK 

 

 

 

Summary of Contents for AMX MU Series

Page 1: ...pg 1 Instruction Manual MU Series Automation Controllers...

Page 2: ...tic charges as possible Grounding straps conductive smocks and conductive work mats are specifically designed for this purpose These items should not be manufactured locally since they are generally c...

Page 3: ...qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the a...

Page 4: ...ed under the 2006 66 EC European Directive which cannot be disposed of with normal household waste Please dispose of any used batteries properly following any local regulations Do not incinerate WARNI...

Page 5: ...nd can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interf...

Page 6: ...ea level it can only be used in locations below 2000 meters above sea level Using the device above 2000 meters could result in a potential safety hazard This logo applies to electronic information pro...

Page 7: ...tion for electrical and electronic equipment consists of the crossed out wheeled bin as shown below This product must not be disposed of or dumped with your other household waste You are liable of dis...

Page 8: ...MU 1300 14 MU 1300 SPECIFICATIONS 14 MU 2300 16 MU 2300 SPECIFICATIONS 16 MU 3300 18 MU 3300 SPECIFICATIONS 18 MOUNTING THE CONTROLLER 20 MOUNTING THE MU 2300 AND MU 3300 20 INSTALLING THE CONTROLLER...

Page 9: ...25 USING THE ICSLAN NETWORK 25 ICSLan Network Settings 25 DHCP Server 25 Opening LAN and ICSLAN Sockets from Code 25 LAN 10 100 PORT 25 IPv4 25 IPv6 25 INPUT PWR CONNECTOR 26 PREPARING CAPTIVE WIRES...

Page 10: ...orite sites like Stack Overflow are there for reference and help Duet Module and Driver Design Module support The MU series platform still supports Duet modules This gives you control of 1000s of devi...

Page 11: ...x 5 1 8 42 16 mm x 147 32 mm x 130 81 mm DIN Rail mountable with DIN Rail Clip AMX CAC0001 4 GB DDR3 RAM 8 GB eMMC Storage 2x USB 2 0 Type A Host port 1x USB Type C program port MU 2300 AMX CCC023 1...

Page 12: ...Between Failure MTBF 100000 hours Memory 4 GB DDR3 RAM 8 GB eMMC Weight 1 26 lbs 572g Enclosure Powder Coated Steel Gray Pantone 10393C Certifications ICES 003 CE EN 55032 AUS NZ CISPR 32 CE EN 55035...

Page 13: ...network USB Host Port 2x Type A USB host port USB Mass Storage for external logging FLIRC IR Receiver for IR hand control input General Specifications Operating Environment Operating Temperature 32 F...

Page 14: ...ltage 9 18 VDC Power Consumption 26 Watts Max Mean Time Between Failure MTBF 100000 hours Memory 4 GB DDR3 RAM 8 GB eMMC Weight 1 58 lb 718g Enclosure Powder Coated Steel Gray Pantone 10393C Certifica...

Page 15: ...n double stack Phoenix connector All remaining device control connections Lower 10 pins RS 232 422 485 plus hw handshaking power Upper Left 6 pins 4 Input Output plus Ground and Power Upper Right 4 pi...

Page 16: ...Gray Pantone 10393C Certifications ICES 003 CE EN 55032 AUS NZ CISPR 32 CE EN 55035 CE EN 62368 1 IEC 62368 1 UL 62368 1 VCCI CISPR 32 RoHS WEEE compliant Front Panel Components Status LED RGB LED se...

Page 17: ...Handshaking CTS Clear to Send for Hardware Handshaking TXD Unbalanced line output for RS 232 RXD Unbalanced line input for RS 232 GND Signal ground for RS 232 Relays 1 4 3 5mm Phoenix 8 pin connector...

Page 18: ...Gray Pantone 10393C Certifications ICES 003 CE EN 55032 AUS NZ CISPR 32 CE EN 55035 CE EN 62368 1 IEC 62368 1 UL 62368 1 VCCI CISPR 32 RoHS WEEE compliant Front Panel Components Status LED RGB LED see...

Page 19: ...to Send for Hardware Handshaking TXD Unbalanced line output for RS 232 RXD Unbalanced line input for RS 232 GND Signal ground for RS 232 Relays 1 8 3 5mm Phoenix 8 pin connector 4 pairs Contact Closu...

Page 20: ...installation test the incoming wiring by connecting the Controller s connectors to their terminal locations and applying power Verify that the unit is receiving power and functioning properly Disconne...

Page 21: ...standard USB cabling to connect to any mass storage or peripheral devices FIG 10 USB Type A host port on MU 1300 Left and MU 2300 MU 3300 Right LEDs This section details the various LEDs on the front...

Page 22: ...t SERIAL LEDs The MU 2300 has two sets of four LEDs TheMU 1300 has two sets of two LEDs RELAYS LEDs The RELAYS LEDs light red to indicate that the corresponding relay port is active The light toggles...

Page 23: ...and displays These ports support most standard RS 232 communication protocols for data transmission The following table lists the pinouts for the RS 232 ports RS 232 Port Pinout Signal Function GND Si...

Page 24: ...nput or a digital output Threshold settings are available to determine the high low points for the digital input and the required voltage change to generate an update Digital Output can push or pull 1...

Page 25: ...ill serve IP addresses to any connected devices set to DHCP mode The DHCP server can be disabled from the MU controller s built in web server The DHCP address range is assigned to half the available I...

Page 26: ...color The ID Pushbutton functionality is as follows ID Button Hold Duration Status LED color Function Performed on Release Not held Green blinking if scripts are running Running normally 0 10 seconds...

Page 27: ...to their default 9600 8 data bits 1 stop bit No parity 422 485 disabled All I O s return to digital input mode with default threshold values A Factory Firmware reset includes a Configuration Reset and...

Page 28: ...arks registered trademarks of their respective companies AMX does not assume responsibility for errors or omissions AMX also reserves the right to alter speci cations without prior notice at any time...