Programming
65
Modero G4 Touch Panels - Configuration & Programming Manual
Button Commands (Cont.)
^BNC
Clear current TakeNote annotations.
•
Syntax
:
"'^BNC-<vt addr range>,<command value>'"
•
Variables
:
variable text address range = 1 - 4000.
command value = (0= clear, 1= clear all).
•
Example
:
SEND_COMMAND Panel,"'^BNC-973,0'"
Clears the annotation of the TakeNote button with variable text 973.
^BNN
Set the TakeNote network name for the specified Addresses.
•
Syntax
:
"'^BNN-<vt addr range>,<network name>'"
•
Variables
:
variable text address range = 1 - 4000.
network name = Use a valid IP Address.
•
Example
:
SEND_COMMAND Panel,"'^BNN-973,192.168.169.99'"
Sets the TakeNote button network name to 192.168.169.99.
^BNT
Set the TakeNote network port for the specified Addresses.
•
Syntax
:
"'^BNT-<vt addr range>,<network port>'"
•
Variables
:
variable text address range = 1 - 4000.
network port = 1 - 65535.
•
Example
:
SEND_COMMAND Panel,"'^BNT-973,5000'"
Sets the TakeNote button network port to 5000.
^BOP
Set the button opacity. The button opacity can be specified as a decimal between 0 - 255, where zero (0) is invisible and
255 is opaque, or as a HEX code, as used in the color commands by preceding the HEX code with the # sign. In this case,
#00 becomes invisible and #FF becomes opaque. If the opacity is set to zero (0), this does not make the button inactive,
only invisible.
•
Syntax
:
"'^BOP-<vt addr range>,<button states range>,<button opacity>'"
•
Variables
:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons 1 = Off state and 2 = On state).
button opacity = 0 (invisible) - 255 (opaque).
•
Example 1
:
SEND_COMMAND Panel,"'^BOP-500.504&510.515,1,200'"
•
Example 2
:
SEND_COMMAND Panel,"'^BOP-500.504&510.515,1,#C8'"
Both examples set the opacity of the buttons with the variable text range of 500-504 and 510-515 to 200.