background image

Burn Only the Fuel for which the Heater is Equipped

the clarity Direct vent is built for use with Propane 

but can be converted to burn natural Gas.the label on the 

burner  system  module  indicates  the  fuel  for  which  it  is 

equipped, and must be marked upon installation of the stove  

or conversion kit. a second label, located near the rating 

plate, also indicates the fuel type.

For  fuel  conversion  information,  see APPENDIX A 

(page 28)

Making The Connection

the  gas  inlet  is  located  at 

the  bottom  right  rear  of  the 

stove. The inlet fitting is a 1/2" 

female flare flexible pipe.

a separate gas shut-off valve 

and  a  1/8"  n.P.t.  plugged 

tapping  should  be  installed 

immediately upstream of the 

connection to the appliance.

the clarity Direct vent Gas heater must be discon-

nected  from  the  gas  supply  piping  during  any  pressure 

testing of that system at pressures in excess of 1/2 psig 

(3.5 kPa).

the clarity gas control valve must be in the oFF posi-

tion during any pressure testing of the gas supply system at 

pressures equal to or less than 1/2 psig (3.5 kPa).

WARNING: To avoid pipe compounds from enter-

ing into the gas train, apply compounds only to male 

pipe threads and do not apply compound to the first 

two threads.

caution: test aLL  Joints  For  LeaKs  Be-

Fore oPeratinG 

Gas Pressure Requirements

Correct gas pressure and the use of a properly sized 

gas supply line are essential  for the safe and efficient per

-

formance of this appliance. Make sure that the plumber or 

gas supplier checks the gas supply line and gas pressure at 

installation.

 note: improper gas pressure can affect heater perfor-

mance, flame color, or cause pilot outage.

WARNING: This product must be installed by a li-

censed plumber or gas fitter when installed within the 

Commonwealth of Massachusetts.

Natural Gas: 

Maximum  inlet  pressure  7.0"  w.c.  (1.74  kPa)   

Minimum  inlet  pressure  5.0"  w.c.  (1.25  kPa)  

Gas manifold pressure 3.5" w.c. (0.87 kPa)

LPG Gas: 

Maximum  inlet  pressure  13"  w.c.  (3.24  kPa)   

Minimum  inlet  pressure  11"  w.c.  (2.74  kPa)  

Gas manifold pressure 10" w.c. (2.49 kPa)

CONNECTING THE HEATER TO A GAS SUPPLY

NATURAL GAS

PROPANE

Pipe Length    schedule 40 Pipe 

tubing, type L

(Feet) 

inside Diameter 

outside Diameter

 

n.G. 

L.P. 

n.G. 

L.P.

0-10 

1/2” 

3/8” 

1/2” 

3/8”

 

1.3 cm 

1.0 cm 

1.3 cm 

1.0 cm

10-40 

1/2” 

1/2” 

5/8” 

1/2”

 

1.3 cm 

1.3 cm 

1.6 cm 

1.3 cm

40-100 

1/2” 

1/2” 

3/4” 

1/2”

 

1.3 cm 

1.3 cm 

1.6 cm 

1.3 cm

100-150 

3/4” 

1/2” 

7/8” 

3/4”

 

2.0 cm 

1.3 cm 

2.3 cm 

2.0 cm

recoMMenDeD Gas PiPe DiaMeter

note: never use PLastic PiPe. checK to conFirM

Whether Your LocaL coDes aLLoW coPPer

tuBinG or GaLvaniZeD PiPe.

installer Fuel Label shown below. note that when 

converting to natural Gas, the appropriate label must be 

installed.

Summary of Contents for Clarity 929 DV

Page 1: ...type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used Cet appareil peut tre install dans une maison pr fabriqu e mobile d...

Page 2: ...ing the Gas Flame 19 OPERATION 20 How to Light the Fire 20 How to Turn Off the Fire 20 Lighting Instructions 21 Maintenance 22 Removing the Glass 22 Replacing the Gasket 22 Cleaning the Glass 22 Inspe...

Page 3: ...ion and the accessibility of the gas and electrical supply must all be considered In addition selecting a location that takes advantage of the building s natural air flow is also desirable to maximize...

Page 4: ...idth and depth of the appliance Clearance to back wall 3 75 mm IMPORTANT NOTICE Due to high temperatures the Clarity Direct Vent Gas Heatershould be located out of traffic and away from furniture and...

Page 5: ...nsult your local building codes before beginning the installation and follow the manufacturer s instructions exactly The following Simpson Duravent GS 4 X 6 5 8 venting components are approved for use...

Page 6: ...om the center line of the terminal E Clearance to unventillated soffit F Clearance to outside corner G Clearance to inside corner H Clearance to each side of center line extended above meter regulator...

Page 7: ...VENTING Vent cap regulations These Diagrams along with the table detail the restrictions on the vent terminal location...

Page 8: ...ermination 14 984 1284 Horizontal Square Termination 980 1280 Vertical Termination 991 1291 Vertical Termination High Wind 950 1250 Vinyl Siding Standoff 1222D Only available from Harman 8 x 5 to 6 5...

Page 9: ...ipe Length Galvanized 4DT 9B 9 Pipe Length Black 4DT 12 12 Pipe Length Galvanized 4DT 12B 12 Pipe Length Black 4DT 18 18 Pipe Length Galvanized 4DT 18B 18 Pipe Length Black 4DT 24 24 Pipe Length Galva...

Page 10: ...V4EBR90 990B SV5EBR90 1290B Adjustable Decorative Square Cathedral Support SV4CSB 941 SV5CSB 1241 Collar for the Decorative Square Cathedral Support SV4AC n a SV5AC n a Decorative Black Plate square S...

Page 11: ...section female female MFL18 24 flex section female female MFL2 36 flex section female female MFL3 48 flex section female female MFL4 Elbows 45 solid elbow section female male connectors EEL45 90 elbo...

Page 12: ...7 12 to 12 12 pitch roof MRF 12 Flashing and storm collar for 7 12 to 12 12 pitch roof Bulk pack of 6 MRF1206 Horizontal Vent Restrictors For 8 14 horizontal vent run MHVR8 For 15 24 horizontal vent...

Page 13: ...ion female mal PEXT4 72 rigid section female male PEXT6 Flex Sections 12 flex section female female connectors PFL1 18 flex section female female PFL18 24 flex section female female PFL2 36 flex secti...

Page 14: ...upport plate support ring PSPXT 8 8 Support plate support ring Bulk pack of 6 PSP806 Flashing and storm collar for 1 12 to 7 12 pitch roof PRF7 Flashing and storm collar for 1 12 to 7 12 pitch roof Bu...

Page 15: ...1 88b 2003 CSA2 33b 2003 test methods and the resulting ITS WHI product certfication The code Authority Having Jurisdiction must be consulted prior to proceeding assembly Remove and Unwrap the Log Set...

Page 16: ...p of the back log and the other on the top of the center log Secure the Glass Front NOTE The glass front is heavy Lift it carefully to pre vent damage Center the glass on the opening and suspend it in...

Page 17: ...N TEST ALL JOINTS FOR LEAKS BE FORE OPERATING Gas Pressure Requirements Correct gas pressure and the use of a properly sized gas supply line are essential for the safe and efficient per formance of th...

Page 18: ...h of the wire RECOMMENDED WIRE GAUGES Maximum Wire Length Gauge 100 14 60 16 40 18 25 20 15 22 Connecting the Cordset The Clarity Direct Vent Gas Heater must be installed in accordance with local code...

Page 19: ...factory setting Turn the other two screws as needed to increase or decrease the brightness and length of the flame turning counterclockwise will decrease the flame turning clockwise will increase the...

Page 20: ...control knob counterclockwise to ON 12 Place the ON OFF THERMOSTAT switch in the ON position or in the THERMOSTAT position if the optional thermostat is used 13 Turn on the electric power to the heate...

Page 21: ...21 Safety lighting Label...

Page 22: ...They must have no blockage and be in good repair The vent manufacturer s instructions may provide specific suggestions or details on vent inspection Any sec tions that are taken apart for the inspecti...

Page 23: ...de c blage peuvent entra ner un fonctionnement inad quat et dan gereux S assurer que l appareil fonctionne ad quatement une fois l entretien termin DO NOT USE THIS HEATER IF ANY PART HAS BEEN UNDER W...

Page 24: ...35 3 40 08236 3 40 08237 3 40 08401 3 40 08232 3 40 08233 3 40 08234 3 40 08693 3 40 08225 3 40 08226 3 31 965487 3 40 00141 3 31 08225 3 20 408412 3 20 326007 3 20 326004 3 20 00907 3 42 2312 3 44 10...

Page 25: ...25 3 58 21 18 52 63 27 60 64 61 62 17 51 59 17 16 16 57 24 17 1 53 54 55 56 49 50 parts...

Page 26: ...26 Clarity Burner Module Exploded View 38 36 47 12 13 14 39 48 42 46 40 41 31 32 33 52 53...

Page 27: ...kPa 5 0 1 25 11 0 2 74 Maximum Output Btu hr 0 4500 ft 0 1375 m 31 200 32 100 AFUE seasonal efficiency minimum venting 71 6 73 8 Steady State Efficiency max input blower on High 80 2 83 3 MINIMUM CLEA...

Page 28: ...installing the fuel conversion remove the Glass door and the log set to gain access to the burner module Remove the burner tubes by sliding to the left while lift ing upward Remove the burner cover pl...

Page 29: ...900 4000 5000 49 male 57 male 42 male 35 400 5000 6000 50 male 57 male 42 male 34 000 6000 7000 50 male 57 male 43 male 32 600 7000 8000 51 male 58 male 43 male 31 300 8000 9000 51 male 58 male 44 mal...

Page 30: ...30...

Page 31: ...31...

Page 32: ......

Reviews: