De-rating for High Altitude

For u.s. installations, the clarity Direct vent is approved for elevations up to 2000 feet using the factory-installed burner 

injectors. at elevations above 2000 feet, u.s. codes require a decrease in the input rating by changing the burner injectors 

to a smaller size. The chart below lists by part numbers the appropriate injectors for both LP and natural gas at various 

altitudes.

For canadian installations, the clarity Direct vent is approved for elevations up to 1375 meters (4500 feet). When installing 

the clarity Direct vent at altitudes above 1375 meters (4500 feet), consult the local gas distributor or the authority having 

jurisdiction for proper rating methods.

note: the difference in altitude derating requirements for the u.s. and canada is simply a result of differences in testing 

standards between the two countries.

if the installer must convert the unit to adjust for varying altitudes, an information sticker like the one to the right must be 

filled out and affixed to the appliance at the time of conversion.

 

 

 

NATURAL GAS

 

Front 

Harman 

Center  Harman  

Rear 

Harman   

Nominal Btu  

Altitude 

Injector  Part No. 

Injector  Part No. 

Injector  Part No.   

Input Rate 

0-2000' 

47 

3-40-64347 

56 

3-40-57356 

39 

3-40-64739 

40,000 

2000-3000' 

48 

male 

56 

3-40-57356 

40 

male 

 

38,400

3000-4000' 

49 

male 

56 

3-40-57356 

41 

male 

 

36,900

4000-5000' 

49 

male 

57 

male 

42 

male 

 

35,400

5000-6000' 

50 

male 

57 

male 

42 

male 

 

34,000 

6000-7000' 

50 

male 

57 

male 

43 

male 

 

32,600

7000-8000' 

51 

male 

58 

male 

43 

male 

 

31,300

8000-9000' 

51 

male 

58 

male 

44 

male 

 

30,100

PROPANE

 

Front 

Harman 

Center  Harman  

Rear 

Harman   

Nominal Btu  

Altitude 

Injector  Part No. 

Injector  Part No. 

Injector  Part No.   

Input Rate

 

0-2000' 

56 

3-40-57356 

71 

3-40-57271 

53 

3-40-57753 

40,000 

2000-3000' 

56 

3-40-57356 

71 

3-40-57271 

54 

male 

 

36,900

3000-4000' 

56 

3-40-57356 

71 

3-40-57271 

54 

male 

 

36,900

4000-5000' 

57 

male 

71 

3-40-57271 

54 

male 

 

35,400 

5000-6000' 

57 

male 

71 

3-40-57271 

55 

male 

 

32,600 

6000-7000' 

57 

male 

71 

3-40-57271 

55 

male 

 

32,600 

7000-8000' 

58 

male 

71 

3-40-57271 

56 

3-40-57356 

30,100 

8000-9000' 

58 

male 

71 

3-40-57271 

56 

3-40-57356 

30,100 

THE CONVERSION SHALL BE CARRIED OUT 

BY A  MANUFACTURER'S AUTHORIzED  REP-

RESENTATIVE  IN ACCORDANCE WITH THE 

REQUIREMENTS  OF THE  MANUFACTURER, 

PROVINCIAL OR TERRITORIAL AUTHORITIES 

HAVING jURISDICTION AND IN ACCORDANCE 

WITH THE REQUIREMENTS OF THE CURRENT 

EDITION  OF  CAN/CGA-B141.1  OR  CAN/CGA-

B141.2 INSTALLATION CODES.

APPENDIX B

* When ordering injectors that have no Harman 

part number, specify MALE or FEMALE and the 

appropriate 2 digit injector number.

this appliance has been converted for use at an altitude of __________ft.

Orifice Sizes:   Front ________       Center_________      Rear ________

input (Btu/hr)             _________________
Manifold Pressure      __________________
Fuel type            _______________________
converted By    _________________________________
Date of conversion  _______________________________

Summary of Contents for Clarity 929 DV

Page 1: ...type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used Cet appareil peut tre install dans une maison pr fabriqu e mobile d...

Page 2: ...ing the Gas Flame 19 OPERATION 20 How to Light the Fire 20 How to Turn Off the Fire 20 Lighting Instructions 21 Maintenance 22 Removing the Glass 22 Replacing the Gasket 22 Cleaning the Glass 22 Inspe...

Page 3: ...ion and the accessibility of the gas and electrical supply must all be considered In addition selecting a location that takes advantage of the building s natural air flow is also desirable to maximize...

Page 4: ...idth and depth of the appliance Clearance to back wall 3 75 mm IMPORTANT NOTICE Due to high temperatures the Clarity Direct Vent Gas Heatershould be located out of traffic and away from furniture and...

Page 5: ...nsult your local building codes before beginning the installation and follow the manufacturer s instructions exactly The following Simpson Duravent GS 4 X 6 5 8 venting components are approved for use...

Page 6: ...om the center line of the terminal E Clearance to unventillated soffit F Clearance to outside corner G Clearance to inside corner H Clearance to each side of center line extended above meter regulator...

Page 7: ...VENTING Vent cap regulations These Diagrams along with the table detail the restrictions on the vent terminal location...

Page 8: ...ermination 14 984 1284 Horizontal Square Termination 980 1280 Vertical Termination 991 1291 Vertical Termination High Wind 950 1250 Vinyl Siding Standoff 1222D Only available from Harman 8 x 5 to 6 5...

Page 9: ...ipe Length Galvanized 4DT 9B 9 Pipe Length Black 4DT 12 12 Pipe Length Galvanized 4DT 12B 12 Pipe Length Black 4DT 18 18 Pipe Length Galvanized 4DT 18B 18 Pipe Length Black 4DT 24 24 Pipe Length Galva...

Page 10: ...V4EBR90 990B SV5EBR90 1290B Adjustable Decorative Square Cathedral Support SV4CSB 941 SV5CSB 1241 Collar for the Decorative Square Cathedral Support SV4AC n a SV5AC n a Decorative Black Plate square S...

Page 11: ...section female female MFL18 24 flex section female female MFL2 36 flex section female female MFL3 48 flex section female female MFL4 Elbows 45 solid elbow section female male connectors EEL45 90 elbo...

Page 12: ...7 12 to 12 12 pitch roof MRF 12 Flashing and storm collar for 7 12 to 12 12 pitch roof Bulk pack of 6 MRF1206 Horizontal Vent Restrictors For 8 14 horizontal vent run MHVR8 For 15 24 horizontal vent...

Page 13: ...ion female mal PEXT4 72 rigid section female male PEXT6 Flex Sections 12 flex section female female connectors PFL1 18 flex section female female PFL18 24 flex section female female PFL2 36 flex secti...

Page 14: ...upport plate support ring PSPXT 8 8 Support plate support ring Bulk pack of 6 PSP806 Flashing and storm collar for 1 12 to 7 12 pitch roof PRF7 Flashing and storm collar for 1 12 to 7 12 pitch roof Bu...

Page 15: ...1 88b 2003 CSA2 33b 2003 test methods and the resulting ITS WHI product certfication The code Authority Having Jurisdiction must be consulted prior to proceeding assembly Remove and Unwrap the Log Set...

Page 16: ...p of the back log and the other on the top of the center log Secure the Glass Front NOTE The glass front is heavy Lift it carefully to pre vent damage Center the glass on the opening and suspend it in...

Page 17: ...N TEST ALL JOINTS FOR LEAKS BE FORE OPERATING Gas Pressure Requirements Correct gas pressure and the use of a properly sized gas supply line are essential for the safe and efficient per formance of th...

Page 18: ...h of the wire RECOMMENDED WIRE GAUGES Maximum Wire Length Gauge 100 14 60 16 40 18 25 20 15 22 Connecting the Cordset The Clarity Direct Vent Gas Heater must be installed in accordance with local code...

Page 19: ...factory setting Turn the other two screws as needed to increase or decrease the brightness and length of the flame turning counterclockwise will decrease the flame turning clockwise will increase the...

Page 20: ...control knob counterclockwise to ON 12 Place the ON OFF THERMOSTAT switch in the ON position or in the THERMOSTAT position if the optional thermostat is used 13 Turn on the electric power to the heate...

Page 21: ...21 Safety lighting Label...

Page 22: ...They must have no blockage and be in good repair The vent manufacturer s instructions may provide specific suggestions or details on vent inspection Any sec tions that are taken apart for the inspecti...

Page 23: ...de c blage peuvent entra ner un fonctionnement inad quat et dan gereux S assurer que l appareil fonctionne ad quatement une fois l entretien termin DO NOT USE THIS HEATER IF ANY PART HAS BEEN UNDER W...

Page 24: ...35 3 40 08236 3 40 08237 3 40 08401 3 40 08232 3 40 08233 3 40 08234 3 40 08693 3 40 08225 3 40 08226 3 31 965487 3 40 00141 3 31 08225 3 20 408412 3 20 326007 3 20 326004 3 20 00907 3 42 2312 3 44 10...

Page 25: ...25 3 58 21 18 52 63 27 60 64 61 62 17 51 59 17 16 16 57 24 17 1 53 54 55 56 49 50 parts...

Page 26: ...26 Clarity Burner Module Exploded View 38 36 47 12 13 14 39 48 42 46 40 41 31 32 33 52 53...

Page 27: ...kPa 5 0 1 25 11 0 2 74 Maximum Output Btu hr 0 4500 ft 0 1375 m 31 200 32 100 AFUE seasonal efficiency minimum venting 71 6 73 8 Steady State Efficiency max input blower on High 80 2 83 3 MINIMUM CLEA...

Page 28: ...installing the fuel conversion remove the Glass door and the log set to gain access to the burner module Remove the burner tubes by sliding to the left while lift ing upward Remove the burner cover pl...

Page 29: ...900 4000 5000 49 male 57 male 42 male 35 400 5000 6000 50 male 57 male 42 male 34 000 6000 7000 50 male 57 male 43 male 32 600 7000 8000 51 male 58 male 43 male 31 300 8000 9000 51 male 58 male 44 mal...

Page 30: ...30...

Page 31: ...31...

Page 32: ......

Reviews: