Zone  Controller Wiring 

The Zone Controllers, (ZC-1, ZC-2, ZC-3, ZC-4, ZC-6, ZC-7, ZC-8, ZC-9 and ZC-Fire) can be wired serially 
or in parallel.  To wire in series, each Zone Controller must have an identification or zone number chosen 
using the DIP switches on the side of the controller (see diagram A).  Each controller must have a unique 
number chosen — although there may be multiple Zone Controllers controlling a single zone, or a single Zone 
Controller that controls multiple outputs.  The Zone Controllers can then be wired together and connected to 
the compatible device (e.g., DriveRack

®

 220i, 260, ZonePRO

, etc.) (see diagram B).

The Zone Controllers may also be wired in parallel with the use of the ZC-BOB.  To wire in parallel (home 
run cabling), each controller must have a unique identification or number chosen using the DIP switches on 
the rear of the panel (see diagram A).  To wire in parallel, each controller must be wired into a port of the 
ZC-BOB with a connecting wire going to the controlled device (see diagram C).  Diagram D shows the typical 
wiring for ZC-4 Euroblock connections in which the installer needs to use SPDT (single-pole, double-throw) 
switches with one side being connected to 5 volts (+VREF) and the other side to ground (GND).  Diagram E 
shows the proper way to interface the ZC-Fire to the fire alarm system.  Use only the relay/switch closure or 
the 5-24V DC inputs.  Do not use both inputs at the same time. For information regarding ZC setup, please 
see the respective manual for the device that you are setting up. 

RS-232

Diagram B

Diagram A

Summary of Contents for dbx ZC Series

Page 1: ...ZCSERIES Wall Mounted Zone Controllers ZC 1 4 ZC 6 9 ZC Fire ZC BOB User Guide...

Page 2: ...vicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen i...

Page 3: ...ed in parallel with the use of the ZC BOB To wire in parallel home run cabling each controller must have a unique identification or number chosen using the DIP switches on the rear of the panel see di...

Page 4: ...ected to the V reference Because there are four switch inputs there are 16 possible switch combinations In the chart above a 0 corresponds to a switch connected to the ground reference a 1 corresponds...

Page 5: ...lowing cable length restrictions apply As shown in Diagram F any 3 Zone Controllers may be wired in series as long as the total cable length does not exceed 600 feet Any 6 Zone Controllers may be wire...

Page 6: ...4 USER GUIDE ZC Series Wall Controllers RS 232 Diagram G RS 232 Diagram H RS 232 Diagram F...

Page 7: ...e Orange Voltage Reference 2 2 Orange Controller 1 7 3 3 White Green Controller 2 8 4 4 Blue Controller 3 9 5 5 White Blue Controller 4 10 6 6 Green Controller 5 11 7 7 White Brown Controller 6 12 Zon...

Page 8: ...RJ 45 1 6 Pin Phoenix ZC BOB Connectors 7 RJ 45 ZC Fire Connectors 2 RJ 45 2 2 Pin Phoenix Wiring Maximum cable length depends on number of Zone Controllers and wiring schematic Series Wiring Maximum...

Page 9: ...7 USER GUIDE ZC Series Wall Controllers Dimensions ZC 1 ZC 2 ZC 3 ZC 6 ZC 7 33 0 105 7 96 77 7 11 24 46 15 52 83 31 66 29 ZC 8 and ZC 9 114 3 83 31 69 85 22 86 20 07...

Page 10: ...8 USER GUIDE ZC Series Wall Controllers ZC 4 ZC BOB and ZC Fire 53 34 120 7 40 89 133 1 ZC 1 ZC 2 ZC 3 ZC 6 ZC 7 ZC 8 and ZC 9 EU Models...

Page 11: ...Phone 801 566 8800 Website dbxpro com Support dbxpro com en US support ZC Series User Guide PN 5081469 A dbx Professional Products is a registered trademark of HARMAN 2016 HARMAN All rights reserved...

Reviews: