background image

 3

IMPORTANT SAFETY INFORMATION

WARNING FOR YOUR PROTECTION

READ THESE INSTRUCTIONS:

KEEP THESE INSTRUCTIONS

HEED ALL WARNINGS

FOLLOW ALL INSTRUCTIONS

THE APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR 

SPLASHING LIQUID AND NO OBJECT FILLED WITH LIQUID, SUCH 

AS VASES, SHALL BE PLACED ON THE APPARATUS

CLEAN ONLY WITH A DRY CLOTH.

DO NOT BLOCK ANY OF THE VENTILATION OPENINGS. INSTALL IN 

ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS.

DO NOT INSTALL NEAR ANY HEAT SOURCES SUCH AS 

RADIATORS, HEAT REGISTERS, STOVES, OR OTHER APPARATUS 

(INCLUDING AMPLIFIERS) THAT PRODUCE HEAT.

ONLY USE ATTACHMENTS/ACCESSORIES SPECIFIED BY THE 

MANUFACTURER.

UNPLUG THIS APPARATUS DURING LIGHTNING STORMS OR WHEN 

UNUSED FOR LONG PERIODS OF TIME.

Do not defeat the safety purpose of the polarized or grounding-type 

plug.  A polarized plug has two blades with one wider than the 

other. A grounding type plug has two blades and a third grounding 

prong. The wide blade or third prong are provided for your safety. If 

the provided plug does not fit your outlet, consult an electrician for 

replacement of the obsolete outlet.

Protect the power cord from being walked on or pinched particularly 

at plugs, convenience receptacles, and the point where they exit from 

the apparatus.

Use only with the cart stand, tripod bracket, or table specified by 

the manufacture, or sold with the apparatus. When a cart is used, 

use caution when moving the cart/apparatus combination to avoid 

injury from tip-over.  Refer all servicing to qualified service personnel. 

Servicing is required when the apparatus has been damaged in any 

way, such as power-supply cord or plug is damaged, liquid has been 

spilled or objects have fallen into the apparatus, the apparatus has 

been exposed to rain or moisture, does not operate normally, or has 

been dropped.

POWER ON/OFF SWITCH: For products provided with a power 

switch, the power switch DOES NOT break the connection from the 

mains.

MAINS DISCONNECT: The plug shall remain readily operable. For 

rack-mount or installation where plug is not accessible, an all-pole 

mains switch with a contact separation of at least 3 mm in each 

pole shall be incorporated into the electrical installation of the rack 

or building.

FOR UNITS EQUIPPED WITH EXTERNALLY ACCESSIBLE FUSE 

RECEPTACLE: Replace fuse with same type and rating only.

MULTIPLE-INPUT VOLTAGE: This equipment may require the use 

of a different line cord, attachment plug, or both, depending on the 

available power source at installation. Connect this equipment only to 

the power source indicated on the equipment rear panel. To reduce 

the risk of fire or electric shock, refer servicing to qualified service 

personnel or equivalent.

If connected to 240V supply, a suitable CSA/UL certified power cord shall 

be used for this supply.

SAFETY INSTRUCTIONS 

NOTICE FOR CUSTOMERS IF YOUR UNIT IS EQUIPPED WITH A POWER 
CORD.

WARNING: THIS APPLIANCE SHALL BE CONNECTED TO A MAINS SOCKET 
OUTLET WITH A PROTECTIVE EARTHING CONNECTION.

The cores in the mains lead are colored in accordance with the following code:

GREEN and YELLOW - Earth        BLUE - Neutral        BROWN - Live

As colors of the cores in the mains lead of this appliance may not cor-
respond with the colored markings identifying the terminals in your plug, 
proceed as follows:

•  The core which is colored green and yellow must be connected to the 

terminal in the plug marked with the letter E, or with the earth symbol, 
or colored green, or green and yellow.

•  The core which is colored blue must be connected to the terminal 

marked N or colored black.

•  The core which is colored brown must be connected to the terminal 

marked L or colored red.

 
This equipment may require the use of a different line cord, attachment 
plug, or both, depending on the available power source at installation.  If 
the attachment plug needs to be changed, refer servicing to qualified ser-
vice personnel who should refer to the table below. The green/yellow wire 
shall be connected directly to the units chassis.

CONDUCTOR

WIRE COLOR

Normal

Alt

L

LIVE

BROWN

BLACK

N

NEUTRAL

BLUE

WHITE

E

EARTH GND

GREEN/YEL

GREEN

WARNING: If the ground is defeated, certain fault conditions in the unit or in 
the system to which it is connected can result in full line voltage between 
chassis and earth ground. Severe injury or death can then result if the 
chassis and earth ground are touched simultaneously.

The symbols shown above are internationally accepted symbols 
that warn of potential hazards with electrical products. The light-
ning flash with arrow point in an equilateral triangle means that 
there are dangerous voltages present within the unit. The exclama-
tion point in an equilateral triangle indicates that it is necessary for 
the user to refer to the owner’s manual.

These symbols warn that there are no user serviceable parts inside 
the unit. Do not open the unit. Do not attempt to service the unit 
yourself. Refer all servicing to qualified personnel. Opening the 
chassis for any reason will void the manufacturer’s warranty. Do not 
get the unit wet. If liquid is spilled on the unit, shut it off immediately 
and take it to a dealer for service.  Disconnect the unit during 
storms to prevent damage.

WARNING

RISK OF ELETRIC SHOCK

DO NOT OPEN

AVERTISSEMENT:

 

RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR

WARNING:

 

TO THE REDUCE THE RISK OF FIRE OR ELECTRIC 

SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE

Summary of Contents for JBL Commercial VMA Series

Page 1: ...MA1120 VMA1240 VMA260 VMA2120 Commercial Series 1 Channel 2 Channel Mixer Amplifier Operation Manual 1 VMA 160 1 2 3 4 MUSIC USB MASTER 1 USB 4 VMA 260 1 2 3 MUSIC 1 4 5 6 MUSIC 2 MASTER 2 MASTER 1 VM...

Page 2: ...7 1 3 Rear Panel Controls Connectors VMA160 VMA1120 VMA1240 8 1 4 Rear Panel Controls Connectors VMA260 VMA2120 9 2 0 Setup 10 2 1 Unpacking Your Amplifier 10 2 2 Installing Your Amplifier 10 2 3 Ensu...

Page 3: ...e risk of fire or electric shock refer servicing to qualified service personnel or equivalent If connected to 240V supply a suitable CSA UL certified power cord shall be used for this supply SAFETY IN...

Page 4: ...e following two conditions 1 This device may not cause interference and 2 This device must accept any interference including interference that may cause undesired operation of the device This device c...

Page 5: ...uctuations and Flicker in Low Voltage Supply systems Rated Current less than or equal to 16A EN 55022 2010 Limits and Methods of Measurement of Radio Disturbance Characteristics of ITE Radiated Conduc...

Page 6: ...SR V control module 1 1 Features 5 or 8 inputs with 1 or 2 outputs respectively Ideal for commercial and industrial use System may be expanded by adding JBL Commercial Series Mixers or Commercial Seri...

Page 7: ...ng i e the signal has reached the threshold of audible distortion D Power Switch E Power on LED illuminates blue when power is switched on F Input 1 Front panel audio input capability via 1 4 TRS conn...

Page 8: ...2016DJ2941 HARMAN INTERNATIONAL 1718 W Mishawaka Rd Elkhart IN 46517 Apparatet m tilkoples jordet stikkontakt Apparaten skall anslutas till jordat uttag Laite on liitett v suojakoskettimilla varustet...

Page 9: ...MPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED INCLUDING...

Page 10: ...mplifier make sure you read and observe the Important Safety Instructions found at the beginning of this manual 2 2 Installing Your Amplifier CAUTION Before you begin make sure your amplifier is disco...

Page 11: ...0 mm 17 00 in 401 00 mm 15 79 in 1 USB VMA 260 4 1 2 3 MUSIC 1 4 5 6 MUSIC 2 MASTER 2 MASTER 1 SIDE VIEW FRONT VIEW Figure 2 2 1 Dimensions Front Angle Brackets Rear Angle Brackets Rear Flat Brackets...

Page 12: ...d 3 Install the unit into the cabinet using the rack mount screws through the front angle brackets For details of installation in the chassis of the cabinet refer to the user guide of your cabinet 4 A...

Page 13: ...the amplifier balanced input by using the included Euroblock connectors see Figure 2 4 1 Unbalanced lines may be used but may result in hum or RF noise if using very long cable runs You can also use...

Page 14: ...es should be twisted cable if possible To prevent the possibility of short circuits the wires should be stripped back no greater than 6 mm 1 4 inch see Figure 2 5 1 Suggested below are guidelines to s...

Page 15: ...ustettuun pistorasiaan CONFORMS TO UL STD 60065 CERTIFIED TO CSA STD C22 2 NO 60065 ATTENTION POUR R DUIRE LE RISQUE DE CHOCK LECTRIQUE LA FICHE CENTRALE DE LA PRISE DOIT TRE BRANCH E POUR MAINTENIR L...

Page 16: ...electrician 2 8 Protecting Your Speakers It s wise to avoid clipping the amplifier signal Not only does clipping sound bad but it can damage high frequency drivers The built in clip limiter prevents...

Page 17: ...hazardous and invalidates all agency listings 6 Do not operate the amplifier with the red Clip LEDs constantly flashing 7 Do not overdrive the mixer which will cause clipped signal to be sent to the a...

Page 18: ...ve 70V or 100V speaker systems when connected to the appropriate output terminals As an added feature when driving the high impedance speakers the system automatically apply a 70Hz high pass filter 3...

Page 19: ...d VMA1240 may use Input channel 2 as a priority channel muting all other channels when pins 4 and 5 are shorted using a switch closure The VMA260 and VMA2120 lets Input2 operate with priority over all...

Page 20: ...e This may not work for some Bluetooth devices 8 Press the PLAY PAUSE key to pause or resume playing 9 To disconnect either press the Bluetooth Key or disable Bluetooth at the media player source devi...

Page 21: ...ity over USB The default media player volume is maximum USB and Bluetooth signals cannot be recorded While playing from the USB or Bluetooth source the signal being played is interrupted momentarily w...

Page 22: ...IBLE REASON Mixer channel inputs are turned down POSSIBLE REASON A Priority switch is closed muting all except the priority input POSSIBLE REASON The 70V 100V switch is OFF while using the 70V or 100V...

Page 23: ...ance at any output Power Amp Output 0 5 20Hz 20kHz Signal to Noise Ratio Ref Rated Power mixer levels min master volume max A weighted 76dB Input Impedance nominal Mic 400 Line 20 k balanced RCA 50 k...

Page 24: ...on VOX PTT Attenuation VOX PTT Input 4 Input 5 Input 6 Music 2 TO CH2 TO CH2 TO CH2 TO CH2 TO CH1 TO CH1 TO CH1 TO CH1 Control Input 1 to Ch 2 CH1_PRIORITY CH2_PRIORITY CH1_PRIORITY CH2_PRIORITY Input...

Page 25: ...Feedback MASTER VOLUME REMOTE VOLUME OUTPUT TRANSFORMER CH 1 100V 70V COMMON SPI CLIP VCA POWER AMP HPF Feedback REMOTE VOLUME OUTPUT TRANSFORMER CH 2 100V 70V COMMON SPI CLIP MASTER VOLUME TONE CONTR...

Page 26: ...Input 2 PTT Input 2 Mic Line Bal Music Line Summed RCA VOX Attenuation VOX PTT CH1_PRIORITY VCA POWER AMP HPF TONE CONTROL Hi Z Switch Feedback MASTER VOLUME REMOTE VOLUME OUTPUT TRANSFORMER 100V 70V...

Page 27: ...er Service your system installer or retailer On The World Wide Web www jblcommercialproducts com Professional Contacts Outside the USA Contact the JBL Professional Distributor in your area A complete...

Page 28: ...JBL Commercial 10653 South River Front Parkway Suite 300 South Jordan Utah 84095 Part Number 5078447 A Issue 09 16...

Reviews: