JBL Professional
®
Intellivox ADC Installation Manual
13
202011/ADCIM
PREPARING FOR INSTALLATION
Before starting to install the Intellivox ADC loudspeaker, a
number of points should be considered.
• It is assumed that the installation site has been the subject
of an extensive DDA investigation or optimisation prior to
the actual install. (DDA = Digital Directivity Analysis, the
JBL proprietary simulation software for these products*).
This procedure will have identified the optimum physical
location for the Intellivox ADC, to accurately achieve the
desired acoustic coverage. In particular, the “acoustic
centre” position in terms of height above the finished
floor, and any mechanical mounting angles will have
been specified. The installer should confirm that he/she
has this information.
• Unless specified otherwise by the sound system designer,
the Intellivox ADC Model V90 should be installed at a
position exactly perpendicular to the listening plane
(i.e. vertical if the floor is horizontal). Unlike conventional
loudspeaker systems, minor mechanical misalignment
may lead to degraded coverage and intelligibility. Ensure
(by use of a levelling device such as a spirit level) that
the surface to which the Intellivox is to be attached is
absolutely vertical and that both mounting bracket
positions are in the same plane. This restriction does
not apply to the Model H90, which is intended to be
tilted downwards.
INTELLIVOX ADC CONNECTIONS
The Intellivox ADC range loudspeakers are designed to
be connected to 100 V or 70 V line speaker distribution
systems. They are not intended to be used with amplifiers
which are designed to drive only low-impedance (i.e. 4 - 8
ohms) loudspeakers. However, such amplifiers may be used
if intermediate 100 V/70 V line transformers are connected
between the amplifier outputs and the loudspeakers.
Suitable power amplifiers for use with the Intellivox ADC
range include the AXYS PB-400 and PB-800 models.
In most situations, installation will be simplified by
running the speaker cables to the intended location before
attempting to mechanically mount the Intellivox speakers.
If the loudspeaker is being used as part of a Voice Alarm
application, it is likely that fire-resistant (pyro) cable will
be required; local regulations covering these requirements
should always be checked and followed.
The cable entry gland at the rear of the ADC models can
accept cable with a maximum diameter of 13.5 mm. Ensure
that the cable being installed does not exceed this.
Wiring details can be found on page 14.
3. INSTALLATION GUIDE
*Authorized electro-acoustic consultants or ‘build & design’ sound contractors can download DDA from our website
www.jblpro.com
For further information please refer to the Help files and manual with the DDA software.