background image

Spare Parts List v1.0

Pos. No.

Product Name

P/N

 Description 

Usage

10

Stage-A6002 Primus-6002a 06-020548-2100-0-N MAIN BOARD A6002/6002A

11

Stage A6002, Primus 6002a 9006095002006

INSULATION TAPE W/O GLUE A6002/6002A

12

Stage A6002, Primus 6002a 20M0070000002

DEPRESSION BAR 38MM A6002/6002A

1

13

Stage A6002, Primus 6002a 20M0070000001

DEPRESSION BAR 28MM A6002/6002A

1

15

Stage A6002, Primus 6002a 20M0070000003

DEPRESSION BAR 21MM A6002/6002A

1

17

Stage A6002, Primus 6002a 9006095002004

INSULATION TAPE W/GLUE A6002/6002A

C1 C2

Stage A6002, Primus 6002a 10C5332740001

CAP. 3300U/25V 

20% 105

Ԩ

 A6002/6002A

2

C17 C18

Stage A6002, Primus 6002a 10C6222750001

CAP. 2200UF/35V ±20% A6002/6002A/A9004/9004A

2

CON2

Stage A6002, Primus 6002a 10J500004P001

CONNECTOR 4P JSZ4-03 A6002/6002A

1

CON3

Stage A6002, Primus 6002a 10J500003P001

CONNECTOR 3P JSZ3-03 A6002/6002A/A9004/9004A

1

D16

Stage A6002, Primus 6002a 10D71620CT001

HALF-BRIDGE MUR1620CTR 
A6002/6002AA9004/9004A

1

D17

Stage A6002, Primus 6002a 10D71620CT002

HALF-BRIDGE MUR1620CT A6002/6002AA9004/9004A

1

J1

Stage A6002, Primus 6002a 10J528413A001

CONNECTOR RCA A6002/6002A

1

L7

Stage A6002, Primus 6002a 10L0270000001

TRANSFORMER D27*12-16 A6002/6002A

1

LED1

Stage A6002, Primus 6002a 10D4260030001

LED D3 RED/BLU 3P A6002/6002A/A9004/9004A

1

Q11 Q12

Stage A6002, Primus 6002a 10T0RF3205001

MOS TUBE IRF3205 A6002/6002A/A9004/9004A

2

SW1

Stage A6002, Primus 6002a 10K0010000002

SWITCH 2P3T L8MM A6002/6002A/A9004/9004A

1

TR1

Stage A6002, Primus 6002a 10R4501000002

NTC THERMISTOR 10K A6002/6002A/A9004/9004A

1

U1

Stage A6002, Primus 6002a 10I0DA8920001

IC TDA8920CTH AMP A6002/6002A

1

U2

Stage A6002, Primus 6002a 10I0078L05001

REGULATOR 78L05  A6002/6002A/A9004/9004A

1

U3

Stage A6002, Primus 6002a 10I0J78L12001

IC CJ78L12 A6002/6002A/A9004/9004A

1

U4

Stage A6002, Primus 6002a 10I0J79L12001

IC CJ79L12 A6002/6002A/A9004/9004A

1

U5

Stage A6002, Primus 6002a 10I00TL494001

IC TL494CD A6002/6002A/A9004/9004A

1

U6 U7 U9

Stage A6002, Primus 6002a 10I0L084CN001

IC TL084CN A6002/6002A/A9004/9004A

3

U8

Stage A6002, Primus 6002a 10I0L082CN001

IC TL082CN A6002/6002A/A9004/9004A

1

VR1

Stage A6002, Primus 6002a 10R6200000001

POTENTIOMETER B20K A6002/6002A/A9004/9004A

1

VR3 VR2

Stage A6002, Primus 6002a 10R6100000001

POTENTIOMETER C100K A6002/6002A/A9004/9004A

2

VR4

Stage A6002, Primus 6002a 10R6500000001

POTENTIOMETER B500K A6002/6002A/A9004/9004A

1

Stage A6002, Primus 6002a 10F2200000001

FUSE 20A A9004/9004A/A6002/6002A

1

Stage A6002

50B30A6002001

GIFT BOX A6002

Primus 6002a

50B306002a001

GIFT BOX 6002A

Stage-A6002 Primus-6002a 40S8000300009

5P HIGH INPUT CABLE A6002/6002A

Stage

20M0070157001

JBL LOGO STAGE AMP

Primus

20M0070158002

INFINITY LOGO PRIMUS AMP

Summary of Contents for JBL Stage A3001

Page 1: ... 2019 Ver 1 0 Safety Instruction Warning Notes Specifications Set Block Diagram Schematic Diagrams Layout Diagrams Set Mechanical Exploded View Packaging View Spare Parts List Revision List CONT CONTENTS ENTS 2 5 8 9 12 14 15 16 17 ...

Page 2: ... Statement and Warning Canada Only This Class B digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe B est conforme à la norme NMB 003 du Canada For Canadian Model This Class B digital apparatus complies with Canadian ICES 003 Modèle pour les Canadien Cet appareil numérique de la classe B est conforme à la norme NMB 003 du Canada For Products with Radio Receivers T...

Page 3: ...reasons prior to applying power to the unit under test 2 After removing an electrical assembly equipped with ES devices place the assembly on a conductive surface such as aluminum foil to prevent electrostatic charge build up or exposure of the assembly 3 Use only a grounded tip soldering iron to solder or unsolder ES devices 4 Use only an anti static solder removal device Some solder removal devi...

Page 4: ...rewheads metal overlays control shaft etc Plug the AC line cord of the appliance directly into a 120V AC 60Hz outlet and turn the AC power switch on Any current measured must not exceed o 5mA ANY MEASUREMENTS NOT WITHIN THE LIMITS OUTLINED ABOVE ARE INDICATIVE OF A POTENTIAL SHOCK HAZARD AND MUST BE CORRECTED BEFORE RETURNING THE APPLIANCE TO THE CUSTOMER Device under test Test all exposed metal s...

Page 5: ...ge and subwoofer applications For more than four decades JBL has made the audio experience a lot more satisfying for the car audio enthusiast With a broad array of loudspeakers amplifiers and subwoofers available you can drive with ease and exhilaration These compact amps are equipped with all the important inputs and user controls including a bass EQ as well as LPF and HPF crossover controls for ...

Page 6: ...ow level inputs are used this control adjusts the input sensitivity between 200mVrms and 5 0Vrms When High level inputs are used this control adjusts the input sensitivity between 0 5Vrms and 15Vrms Switchable bass EQ This provides an available bass boost at 45Hz of 6dB or 12dB serving as a great tool to optimize subwoofer and loudspeaker performance based on location and enclosure type Cool indus...

Page 7: ... ohms 70W RMS bridged power 4 ohms 140W Total peak power 560W Frequency response 20Hz 20kHz 1dB THD N at rated power 20Hz 20kHz 1 Line in signal to noise ratio reference to 1 watt 75dB Maximum high input signal level 12V High input maximum sensitivity 0 5V Maximum line input signal level 5V Line input maximum sensitivity 0 2V Quiescent current draw 1 2A Fuse size 2 x 15A Dimensions H x W x L 50 x ...

Page 8: ...SET BLOCK DIAGRAM ...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ......

Page 13: ......

Page 14: ... 0 1 2 8 4 5 0 2 0 6 0 0 1 11 9006095002006 INSULATION TAPE W O GLUE A6002 6002A 1 12 20M0070000002 DEPRESSION BAR 38MM A6002 6002A 1 13 20M0070000001 DEPRESSION BAR 28MM A6002 6002A 1 15 20M0070000003 DEPRESSION BAR 21MM A6002 6002A 1 17 9006095002004 INSULATION TAPE W GLUE A6002 6002A 1 ...

Page 15: ...PACKAGING INSTRUCTIONS ...

Page 16: ...D BLU 3P A6002 6002A A9004 9004A 1 Q11 Q12 Stage A6002 Primus 6002a 10T0RF3205001 MOS TUBE IRF3205 A6002 6002A A9004 9004A 2 SW1 Stage A6002 Primus 6002a 10K0010000002 SWITCH 2P3T L8MM A6002 6002A A9004 9004A 1 TR1 Stage A6002 Primus 6002a 10R4501000002 NTC THERMISTOR 10K A6002 6002A A9004 9004A 1 U1 Stage A6002 Primus 6002a 10I0DA8920001 IC TDA8920CTH AMP A6002 6002A 1 U2 Stage A6002 Primus 6002a...

Page 17: ...Revision List Version 1 0 Initial release for JBL Stage A6002 2019 1 ...