10
DO NOT BURN WET COAL
IMPORTANT
Use only U.L. approved floor board
Front view
Top view
Clearance to Combustibles
INSTAllATION
Place the stove a minimum of 3" from a combustible
wall from the rear of the hopper and a minimum of
24" from the sides. The stove should be placed
on a noncombustible floor, or a minimum 3/8" thick
noncombustible floor protector. Install a 6" stove
pipe from flue opening to chimney with a barometric
damper. Secure all pipe joints with sheet metal
screws. Plug power cord into a 120 volt receptacle.
Refer to the section on operation to light a fire. With
the stove burning and stabilized, set barometric
damper at .04 to .06 on the draft meter. We do not
expect you to own a draft meter. Therefore, have
your dealer do set-up and fine tuning.
If your chimney will not produce .04 on the draft
meter, a draft inducer should be installed by your
dealer. The draft inducer may help to provide the
additional draft needed for proper operation. If not,
the chimney will need to be corrected.