WARRANTY CONDITIONS:

•  This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of 

HHT authorized dealers is available on the HHT branded websites.

•  This warranty is only valid while the HHT appliance remains at the site of original installation.

•  Contact your installing dealer for warranty service. If the installing dealer is unable to provide necessary parts, contact 

the nearest HHT authorized dealer or supplier. Additional service fees may apply if you are seeking warranty service 

from a dealer other than the dealer from whom you originally purchased the product.

•  Check with your dealer in advance for any costs to you when arranging a warranty call. Travel and shipping charges 

for parts are not covered by this warranty.

This warranty is void if:

•  The appliance has been over-fired or operated in atmospheres contaminated by chlorine, fluorine, or other damaging 

chemicals. Over-firing can be identified by, but not limited to, warped plates or tubes, rust colored cast iron, bubbling, 

cracking and discoloration of steel or enamel finishes.

•  The appliance is subjected to prolonged periods of dampness or condensation.

•  There is any damage to the appliance or other components due to water or weather damage which is the result of, but 

not limited to, improper chimney or venting installation. 

LIMITATIONS OF LIABILITY:

•  The owner’s exclusive remedy and HHT’s sole obligation under this warranty, under any other warranty, express or 

implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above. In no 

event will HHT be liable for any incidental or consequential damages caused by defects in the appliance. Some states 

do not allow exclusions or limitation of incidental or consequential damages, so these limitations may not apply to you. 

This warranty gives you specific rights; you may also have other rights, which vary from state to state. EXCEPT TO 

THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY 

SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE 

EXPRESSED WARRANTY SPECIFIED ABOVE.

WARRANTY EXCLUSIONS:

This warranty does not cover the following:

•  Changes in surface finishes as a result of normal use. As a heating appliance, some changes in color of interior and 

exterior surface finishes may occur. This is not a flaw and is not covered under warranty.

•  Damage to printed, plated, or enameled surfaces caused by fingerprints, accidents, misuse, scratches, melted items, 

or other external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes.

•  Repair or replacement of parts that are subject to normal wear and tear during the warranty period. These parts 

include: paint, wood, pellet and coal gaskets, firebricks, grates, flame  guides, light bulbs, batteries and the discolor-

ation of glass.

•  Minor expansion, contraction, or movement of certain parts causing noise. These conditions are normal and com-

plaints related to this noise are not covered by this warranty.

•  Damages resulting from: (1) failure to install, operate, or maintain the appliance in accordance with the installation 

instructions, operating instructions, and listing agent identification label furnished with the appliance; (2) failure to 

install the appliance in accordance with local building codes; (3) shipping or improper handling; (4) improper opera-

tion, abuse, misuse, continued operation with damaged, corroded or failed components, accident, or improperly/ 

incorrectly performed repairs; (5) environmental conditions, inadequate ventilation, negative pressure, or drafting 

caused by tightly sealed constructions, insufficient make-up air supply, or handling devices such as exhaust fans or 

forced air furnaces or other such causes; (6) use of fuels other than those specified in the operating instructions; (7) 

installation or use of components not supplied with the appliance or any other components not expressly authorized 

and approved by HHT; (8) modification of the appliance not expressly authorized and approved by HHT in writing; 

and/or (9) interruptions or fluctuations of electrical power supply to the appliance.

•  Non-HHT venting components, hearth components or other accessories used in conjunction with the appliance.

•  Any part of a pre-existing fireplace system in which an insert or a decorative gas appliance is installed.

•  HHT’s obligation under this warranty does not extend to the appliance’s capability to heat the desired space. Informa-

tion is provided to assist the consumer and the dealer in selecting the proper appliance for the application. Consider-

ation must be given to appliance location and configuration, environmental conditions, insulation and air tightness of 

 the structure.

Summary of Contents for Mark I

Page 1: ...HE U S AND CANADA IF THIS HARMAN STOVE IS NOT INSTALLED CORRECTLY A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOLLOW INSTALLATION DIRECTIONS PRECISELY CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRI...

Page 2: ......

Page 3: ...keep in mind that you will not have instant success with maintaining a fire No one does Following these instructions should help you with the basic principals Safety Notice Stove is hot while in oper...

Page 4: ...g The Stove 2 3 Assembly 2 4 General Information 3 Venting 3 1 Types of Chimneys 3 2 Common Chimney Problems 3 3 What To Do If You Have A Problem 3 4 Chimney Details 4 Grates 4 1 Grate System and Cont...

Page 5: ...s recommendations If there is a discrepancy between these recommendations and your local code requirements you must follow local codes 1 3 CURING PAINT During the first few hours of burning a blue sm...

Page 6: ...ertified by the National Fireplace Institute or similar certification agency B Before starting Installation check for proper clearance to combustibles where the stove is going to be located C Never ve...

Page 7: ...measure the draft drill a hole in the connector pipe and attach a draft meter First check the draft above the barometric damper if installed Then check it below the barometric damper and make your dam...

Page 8: ...ot enough oxygen getting to the fire E Remember open the draft control and crack the door open slightly before reloading or checking the fire F Check the ashes The ash pan and firebox may be overloade...

Page 9: ...opened during the lighting process it must be closed to prevent over firing Over firing can cause dangerously high temperatures 5 2 LOADING Coal should never be added unless there is a reasonably hot...

Page 10: ...d clean the fan If there are pets in your house you may want to check this more frequently Grates Keep ash pan emptied Twice a day Chimney and connector Avoid chimney fires On a regular schedule check...

Page 11: ...Magnafire Series Coal Stoves 11 Optional Water Coil 7 Optional Hot Water Coil Plumbing Diagrams Inside Nut Stove Body Packing Outside Nut Washer...

Page 12: ...han the top leg of the coil The tank should be elevated if necessary to allow for proper thermo siphon action the method by which water will circulate automatically through the system Circulating Pump...

Page 13: ...rranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warra...

Page 14: ...t of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enamel...

Page 15: ...dle 1 2 Pkg of 3 3 40 00086 3 3 4 Short Shaker Handle Weldment 1 10 01001 Y 5 ash door roped 1 10 08143a draft Control Cast 4 00 00109 1 draft Control Gold No longer available 3 00 00109 4 additional...

Page 16: ...of 7 1 00 900450125 Y brick bracket 2 00 01006 brick Set 1 00 00836 Y door Handle Cast 4 00 00042 Y door latch 4 Sets 1 00 00036 Y door Pin 3 8 x 1 7 8 ash Pan load door Pkg of 4 4 30 00138b Y Gasket...

Page 17: ...le Frame 3 40 450850 Y 3 Spring Handle 1 2 Pkg of 3 3 40 00086 3 3 4 Short Shaker Handle Weldment 1 10 01001 Y 5 ash door Cast 4 00 00213d Y draft Control Cast 4 00 00109 1 draft Control Gold No longe...

Page 18: ...door Pkg of 4 4 30 00138a Y Gasket 1 2 round rope load door ash door 20 Ft 1 00 53500 Y Gasket 5 8 Channel glass 5 Ft 1 00 98187 Y Grate Holder Cast Qty 2 req 3 00 00193 Y Grate link 2 Cast Qty 2 req...

Page 19: ...dditional service parts on following page Mark III Magnafire Freestanding Coal Stove 1 70 03227 1 Black Ending Manufacturing Date June 2011 1 70 03227 2 Charcoal Ending Manufacturing Date June 2011 1...

Page 20: ...r Pin 3 8 x 1 7 8 ash Pan Pkg of 4 4 30 00138b Y door Pin 3 8 x 2 1 4 load door Pkg of 4 4 30 00138a Y Gasket 5 8 Channel Glass 5 Ft 1 00 98187 Y Gasket 1 2 round rope load door ash door 20 Ft 1 00 53...

Page 21: ...Magnafire Series Coal Stoves 21 Service Maintenance Log Date Of Service Performed By Description Of Service...

Page 22: ...Magnafire Series Coal Stoves 22 Service Maintenance Log Date Of Service Performed By Description Of Service...

Page 23: ......

Page 24: ...Proudly Printed On 100 Recycled Paper...