Martin PDE Junction Box / Break-In / Break-Out Cable user guide
29
Thermal
Maximum Ambient Temperature (Ta max) ........................................................................ 75 C
Minimum Ambient Temperature (Ta min) ......................................................................... -15 C
Approvals
EU safety .......................................................................................................... EN 60598-2-17
US safety .................................................................................................................... UL 1573
Canadian safety ............................................................................................CSA 22.2 No. 166
Australia/NZ ...................................................................................................................... RCM
United Kingdom ...............................................................................................................UKCA
Break-In Cable Power-DMX-Ethernet to PDE
Physical
Length ......................................................................................................... 500 mm ( 19.7 in.)
Weight............................................................................................................. 325 g (11.5 oz.)
Construction
Housing............................................................................................................................. PVC
Cable Jacket ..................................................................................................................... PVC
Color ................................................................................................................................ Black
Protection Rating ............................................................................................................. IP 65
RoHS ....................................................................................................................... Compliant
REACH .................................................................................................................... Compliant
Connections
AC Power input ......................................................... Neutrik powerCON TRUE1 TOP (IP 65)
DMX input ....................................................................... Neutrik XLR 5-pin Male TOP (IP 65)
Ethernet input........................................................................... Neutrik etherCON TOP (IP 65)
AC Power, DMX and Network out ............................................. PDE hybrid connector (IP 65)
All connections hot plugging compatible
Electrical
AC power .............................................................................. 100-240 V AC nominal, 50/60Hz
Thermal
Maximum Ambient Temperature (Ta max) ....................................................................... 75 C
Minimum Ambient Temperature (Ta min) ........................................................................ -15 C
Break-Out Cable PDE to Power-DMX-Ethernet
Physical
Length .......................................................................................................... 500 mm (19.7 in.)
Weight............................................................................................................. 325 g (11.5 oz.)
Construction
Housing............................................................................................................................. PVC
Cable Jacket ..................................................................................................................... PVC
Color ................................................................................................................................ Black
Protection Rating ............................................................................................................. IP 65
RoHS ....................................................................................................................... Compliant
REACH .................................................................................................................... Compliant
Connections
AC Power, DMX and Network input........................................... PDE hybrid connector (IP 65)
AC Power thru........................................................... Neutrik powerCON TRUE1 TOP (IP 65)