background image

  32 

Martin PDE Junction Box / Break-In / Break-Out Cable user guide 

 

 

 

Disposing of this product 

Martin™ products are supplied in compliance with Directive 2012/19/EC of the European 
Parliament and of the Council of the European Union on WEEE (Waste Electrical and 
Electronic Equipment), where applicable. Help preserve the environment! Ensure that 
this product is recycled at the end of its life. Your supplier can give details of local 
arrangements for the disposal of Martin products

 

 

FCC Compliance 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This 
device may not cause harmful interference, and (2) this device must accept any interference received, including 
interference that may cause undesired operation. 

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to 
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference 
in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not 
installed and used in accordance with the instructions, may cause harmful interference to radio communications. 
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does 
cause harmful interference to radio or television reception, which can be determined by turning the equipment off 
and on, the user is encouraged to try to correct the interference by one or more of the following measures: 

—Reorient or relocate the receiving antenna. 

—Increase the separation between the equipment and receiver. 

—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

—Consult the dealer or an experienced radio/TV technician for help. 

Supplier’s Declaration of Conformity 

Harman Professional, Inc. have issued an FCC Supplier’s Declaration of Conformity for this product. The 
Declaration of Conformity is available for download from the Active Junction Box  area of the Martin website at 
www.martin.com 

Canadian Interference-Causing Equipment Regulations - 

Règlement sur le Matériel Brouilleur du Canada 

This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment 
Regulations CAN ICES-3 (B)/NMB-3(B) and CAN ICES-005 (B) / NMB-005 (B). 

Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le Matériel Brouilleur du 
Canada. 

EU EMC 

Not for use in a computer room as defined in the Standard for the Protection of Information Technology Equipment, 
ANSI/NFPA 75. 

Ne peut être utilisé dans une salle d'ordinateurs telle que définie dans la norme ANSI/NFPA 75 Standard for the 
Protection of Information Technology Equipment.

 

 

 

Summary of Contents for Martin Active Junction Box Power-DMX-Ethernet to...

Page 1: ...Active Junction Box Power DMX Ethernet to PDE Passive Junction Box Power DMX Ethernet to PDE Break In Cable Power DMX Ethernet to PDE Break Out Cable PDE to Power DMX Ethernet User Guide...

Page 2: ...s for connecting devices 16 AC power connection to Junction Box or Break In Cable 16 Data connection to Passive Junction Box or Break In Cable using DMX512 17 Data connection to Passive Junction Box o...

Page 3: ...ve Junction Box Power DMX Ethernet to PDE 115 81 18 2 57 5 199 9 145 A 3 50 5 215 4x 6 8 2x 4 2 4 2 DETAIL A SCALE 1 1 Passive Junction Box Power DMX Ethernet to PDE 3 129 94 4 6 2 4 2 66 30 A Detail...

Page 4: ...injury damage direct or indirect loss consequential or economic loss or any other loss occasioned by the use of inability to use or reliance on the information contained in this document Martin is a...

Page 5: ...r manual for future use For the latest user documentation and other information about this and all Martin products please visit the Martin website at http www martin com If you have any questions abou...

Page 6: ...efore handling Install the product on a non combustible surface brick concrete plaster etc only Allow at least 0 1 m 4 in free space around the product Do not attempt to bypass thermostatic switches o...

Page 7: ...roducts The Break In Cable offers the same functionality as the Passive Junction Box in the form of a cable and provides following connections x Power Input x DMX RDM Input x Ethernet Input x Hybrid P...

Page 8: ...link through 3 Hybrid PDE output connector 4 Test Reset button 5 Status LED 6 Keyhole slots for mounting to wall surface both sides 7 Neutrik etherCON input link through 8 Neutrik XLR 5 DMX link thro...

Page 9: ...1 Neutrik PowerCON TRUE1 input 2 Hybrid PDE output connector 3 Neutrik etherCON input 4 Neutrik XLR5 DMX input 5 Keyhole slots for mounting to wall surface both sides 6 Safety bond attachment point b...

Page 10: ...chain of compatible fixtures 2 DMX RDM input Neutrik XLR5 3 Power input Neutrik powerCON TRUE1 4 Ethernet input Neutrik etherCON Break Out Cable overview 1 2 3 4 1 Hybrid PDE input connector from dais...

Page 11: ...ve the following limitations in selecting a location x Respect the limitations listed under Safety information on page 5 Mounting the junction box The junction box may be mounted directly to a surface...

Page 12: ...Net sACN or P3 is being used as control protocol the total length of hybrid PDE cable between active junction box and first fixture must not exceed 90 m The length of hybrid PDE cable between any two...

Page 13: ...verter For reliable DMX and RDM data transfer it is recommended to terminate each branch with a termination plug this contains a 120 ohm resistor between the cold and hot DMX data lines pins 2 and 3 o...

Page 14: ...ength of Ethernet cable between an Active Junction Box and the next daisy chained Active Junction Box must not exceed 90 m x A shielded Ethernet cable must be used between the console or network switc...

Page 15: ...and the Active Junction Box must not exceed 90 m x The length of Ethernet cable between an Active Junction Box and the next daisy chained Active Junction Box must not exceed 90 m x A shielded Ethernet...

Page 16: ...re on the chain x When Art Net sACN or P3 is being used as control protocol the combined length of Ethernet cable between network switch and junction box and hybrid PDE cable to first fixture must not...

Page 17: ...means that the female PDE connector of the last fixture on a chain need to be fitted with such a termination plug The total length of DMX cable and Hybrid PDE cable combined must not exceed 300 m mea...

Page 18: ...th of hybrid PDE cable between any two daisy chained fixtures may also not exceed 90 m x A shielded Ethernet cable must be used between the between the Network Switch and the Passive Junction Box Brea...

Page 19: ...x The length of hybrid PDE cable between any two daisy chained fixture may also not exceed 90 m x A shielded Ethernet cable must be used between the between the Network Switch and the Passive Junction...

Page 20: ...ample above shows the VDO Atomic Bold and VDO Atomic Dot fixtures but any mix of Martin products with PDE interface can be used After the Break Out Cable the example above shows the MAC Aura PXL but a...

Page 21: ...you can communicate with products using RDM you must send a scan command also called a device discovery command to all the devices on the data link so that the RDM controller can identify them It doe...

Page 22: ...STATUS_MESSAGES 9 STATUS_ID_DESCRIPTION 9 CLEAR_STATUS_ID 9 RDM INFORMATION GET SET SUPPORTED_PARAMETERS 9 PARAMETER_DESCRIPTION 9 PRODUCT INFORMATION GET SET DEVICE_INFO 9 DEVICE_MODEL_DESCRIPTION 9...

Page 23: ...NTIFY_DEVICE 9 9 RESET_DEVICE 9 NETWORK CONFIGURATION GET SET LIST_INTERFACES 9 INTERFACE_LABEL 9 INTERFACE_HARDWARE_ADDRESS_TYPE1 9 IPV4_DHCP_MODE 9 IPV4_CURRENT_ADDRESS 9 IPV4_STATIC_ADDRESS 9 9 INT...

Page 24: ...chain perform a product reboot or perform a factory reset of the Active Junction Box just like other Martin Creative LED products If the pushbutton is given a short press the first internal test patte...

Page 25: ...quently to see whether cleaning is necessary If in doubt consult your Martin dealer about a suitable maintenance schedule To clean the product use warm water and a soft brush or a low pressure or medi...

Page 26: ...ector or cable damaged or incorrect DMX addressing or potential interference from proximity to a high voltage installation Check if the product status LED is flashing red to show that control data is...

Page 27: ...bypass to Ethernet IN Ethernet Transceiver OUT 10 100Mbit Firmware Update via DMX using Martin Companion or via Ethernet using P3 System Controller Control User Interface Device Status Multi color st...

Page 28: ...00 3 2 EN 61000 3 3 EN 61547 US Safety UL1573 US EMC 47 CRF 15 Class B Canadian Safety CSA 22 2 No 166 Canadian EMC ICES 003 Class B ICES 005 Class B Australia NZ RCM United Kingdom UKCA Passive Junct...

Page 29: ...AC Power input Neutrik powerCON TRUE1 TOP IP 65 DMX input Neutrik XLR 5 pin Male TOP IP 65 Ethernet input Neutrik etherCON TOP IP 65 AC Power DMX and Network out PDE hybrid connector IP 65 All connect...

Page 30: ...E1 5 m 16 4 ft P N 91611786 Power Input Cable SJOOW 12 AWG bare ends to TRUE1 1 5 m 4 9 ft P N 91610173 Power Input Cable SJOOW 12 AWG bare ends to TRUE1 5 m 16 4 ft P N 91610174 Power Relay Cable H07...

Page 31: ...Martin PDE Junction Box Break In Break Out Cable user guide 31...

Page 32: ...rticular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to co...

Page 33: ...www martin com Olof Palmes All 44 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010 Harman Professional Solutions 8500 Balboa Blvd Northridge CA 91329 United States...