Dry Seasoned Wood Only!
Oakleaf Woodburning Stove
Harman® • Oakleaf Owner's Manual_R23 • 2010 -___ • 09/15
21
3-90-798
A. Mobile Home Installation
Mobile home approval - U.S. only.
DO NOT INSTALL IN A MOBILE HOME IN CANADA.
1. An outside air inlet must be provided for combustion
air, and must remain clear of leaves, debris, ice, and/or
snow. The outside air path must be unrestricted while
the appliance is in operation.
2. The combustion air intake system must be of metal
construction. It must permit zero-clearance to
combustible materials, and contain a rodent screen.
3. The appliance must be secured to the mobile home
structure by bolting it to the floor. There are brackets
included, you'll need to secure with the proper length
lag bolts.
4. The appliance must be properly grounded to the frame
of the mobile home using a minimum of 8 AWG copper
solid or stranded, insulated or bare wire or equivalent.
5. All clearances to combustibles and floor protection
requirements must be followed.
6. Follow the vent manufacturer's instructions when
installing in a mobile home.
7. Installation shall be in accordance with the Manufactured
Home and Safety Standard (HUD) CFR 3280, Part 24
8. The appliance must never be installed in a room
designated for sleeping.
6
Mobile Home
INSTALLATION MUST COMPLY WITH
MANUFACTURED HOME AND SAFETY STANDARD
(HUD), CFR 3280, PART 24.
WARNING
!
NEVER INSTALL IN A ROOM INTENDED FOR
SLEEPING.
WARNING
!
MAINTAIN STRUCTURAL INTEGRITY OF MOBILE
HOME:
• FLOOR, WALL, CEILING AND/OR ROOF.
DO NOT CUT THROUGH:
• FLOOR JOIST, WALL STUDS, OR CEILING
TRUSSES.
• ANY SUPPORTING MATERIAL THAT WOULD
AFFECT THE STRUCTURAL INTEGRITY.
CAUTION
!
NEVER DRAW OUTSIDE COMBUSTION AIR FROM:
• WALL, FLOOR OR CEILING CAVITY.
• ENCLOSED SPACE SUCH AS AN ATTIC OR
GARAGE
CAUTION
!
This diagram shows the bracket that was used to bolt the stove to the
pallet. Use at least two of these brackets for securing the appliance
through the floor in a mobile home installation. The bracket will
slip over the top of the leveling adjuster. The installer will need to