background image

4

Harman Oakwood

3-90-08327R26_03/14

Harman Oakwood Wood Stove

Label Measures: 7" high X 7.75" wide

BARCODE LABEL

008

Serial No.

N

o

 de série:

CAUTION

: HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP 

CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. 

SEE NAMEPLATE AND INSTRUCTIONS. KEEP FURNISHINGS AND OTHER 

COMBUSTIBLE MATERIALS A CONSIDERABLE DISTANCE AWAY FROM 

THIS APPLIANCE.

ATTENTION

: CHAUD-NE PAS TOUCHER. TENIR LES ENFANTS 

ET LES VENTEMENTS A L’ECART. RISQUE DE BRULURE. VOIR 

INSTRUCTIONS SUR LA PLAQUE. LAISSER UNE DISTANCE SUFFISANTE 

ENTRE L’APPAREIL ET LES MEUBLESOU AUTRES OBJECT A RISQUE.

PREVENT HOUSE FIRES:

Install and use only in accordance with manufacturer’s installation and operation instructions and local 

building codes. In absence of any local codes, installation must meet minimum requirements of NFPA 211 

in USA. Refer to manufacturer’s instructions and local codes for precautions required for passing chimney 

through a combustible wall or ceiling.

FOR USE WITH SOLID WOOD FUEL ONLY.

Don’t connect this stove to a chimney serving another appliance.

Flue connector pipe must be 6” diameter, minimum 24 MSG black or 26 MSG blue steel.

Chimney must be factory built UL 103HT or masonry.

NOTE:

 Replace glass only with 5mm ceramic glass available from your dealer.

Inspect and clean chimney frequently. Under certain conditions of use, creosote buildup may occur rapidly.

DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR GLOWS, YOU ARE OVERFIRING.

 

DO NOT obstruct the space beneath the appliance.

LISTED SOLID FUEL FIREPLACE STOVE OR ROOM HEATER/

APPAREIL DE CHAUFFAGE OU POELE A COMBUSTIBLE SOLIDE

MODEL/Modèle: OAKWOOD

CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA/

CONTACTEZ LE BUREAU DE LA CONSTRUCTION OU LE BUREAU DES INCENDIES AU DES RESTRICTIONS ET DE L’INSPECTION 

D’INSTALLATION DANS VOTRE VOISINAGE

PRéVENTION DES INCENDIES:

Respectez scrupuleusement les instructions du constructeur pour l’installation et l’utilisation. Respectez 

les règles et normes applicables dans votre région. Dans tous les cas, l’installation devra au minimum 

satisfaire aux exigences de NFPA 211 AUX Etats-Unis.

Reportez vous aux instructions du fabricant et aux règles locales pour les précautions nécessaires lors 

du passage des tuyaux de fumée à travers un mur ou un plafond combustible. contrôlez et nettoyez 

fréquemment la cheminée et les tuyaux de fumée selon les instructions du fabricant.

N’UTILISEZ QUE DU BOIS EN BUCHES:

Ne pas raccorder ce poêle à un conduit de fumée utilisé pour un autre appareil.

Le tuyau de fumée doit avoir 6” de diamètre minimum, et être en acier de qualité 24MSG noir ou 26 

MSG bleu.

La conduit de fumée peut être maçonné ou de fabrication industrielle type ULC S629.

Nota:

 Ne remplacer la vitre qu’avec une vitre céramique de 45 mm disponible chez votre fournisseur.

Contrôlez et nettoyez fréquemment la cheminée et les tuyaux de fumée. Dans certaines conditions 

d’utilisation, des accumulations de créosote peuvent se produire rapidement.

NE PAS SUR CHAUFFER - SI LE POELE OU LE TUYAU ROUGISSENT, VOUS SURCHAUFFEZ!

Ne pas obstruer l’espace en dessous du bruleur.

CLEARANCE TO COMBUSTIBLE SURFACE

A - Unit to Side Wall 

          26” (660mm)

B - Unit to Back Wall 

          28” (711mm)

C - Chimney Connector to Side Wall     38” (965mm)

D - Chimney Connector to Back Wall    32” (813mm)

E - Unit to Adjacent wall 

          24” (610mm)

F - 

Chimney Connector to Adjacent wall     

32” (813mm)

*See manual for additional installation configurations.

ESPACES LIBRES AUX COMBUSTIBLES

A - Du mur de côté à l’appareil                   26” (660mm)

B - Du mur arrière àl’appareil                   28” (711mm)

C - Du tuyau de cheminée au mur de côté   38” (965mm)

D - Du tuyau de cheminée au mur arrière     32” (813mm)

E - Entre le mur adjacent et l’appareil           24” (610mm)

F - Entre la tuyau et le mur adjacent             32” (813mm)

* Voir le manuel pour d’autres configurations d’installation

Floor protection must be a 3/4” min. thickness, non-combustible 

material having an equal or better insulating value (lower k 

value) of k=.84 BTU/In Ft

2

 Hr °F, extending beneath heater 

and to front/sides/rear as indicated. In Canada, required floor 

protection must be 18” (450mm) in front.
Leprotecteur de plancher doit être d’une epaisseur minimum de 

3/4” d’un material incombustible ayant une valeur d’isolation de 

k=.84 BTU/in Ft

2

 Hr °F. 

Il doit s’etendre et à l’arriêre de l’appareil comme indiquè.

‘Au Canada, la preotection du plancher doit s’étendre de 18” 

(450mm) en avant.

Manufactured by/Fabriqué par: Hearth and Home Technologies

352 Mountain House Road

Halifax, Pa 17032

2013   2014   2015   JAN   FEB   MAR   APR   MAY   JUN   JUL   AUG   SEP   OCT   NOV   DEC

U.S. ENVIROMENTAL PROTECTION AGENCY

CERTIFIED TO COMPLY WITH JULY 1990 PARTICULATE EMISSIONS STANDARD

Date of Manufacture / Date de fabrication

Rev C

P.N. 3-90-249

BACKWALL

SIDE

W

ALL

A

C

B

D

ADJACENT WALL

ADJA

CENT W

ALL

E

F

8”

8”

8”

16”

BACKWALL

SIDE

W

ALL

A

C

B

D

ADJACENT WALL

ADJA

CENT W

ALL

E

F

8”

8”

8”

16”

FLOOR PROTECTOR

FRONT

BACKWALL

SIDE

W

ALL

A

C

B

D

ADJACENT WALL

ADJA

CENT W

ALL

E

F

8”

8”

8”

16”

Tests réalisés par OMNI-Test Laboratories, Inc.

Report #/Rapport #135-S-11-2

Tested to/Testé selon: August 2002, UL 1482-1996, 

UL 737-1996 and ULC-S627-00

Certified  for  U.S.A.  and  Canada/Certifié  pour  les 

états-Unis et le Canada

Thank you for purchasing the Harman® Oakwood. We are confident that you will enjoy the warmth and convenience of your 

Harman® Stove for decades to come. 
The Harman® Oakwood will heat your home while also being multi-functional and visually appealing. When building your 

Oakwood, we used only the best precision castings that were designed, so accurately, that gaskets are used (instead of 

furnace cement) for assembly. 
Harman’s special FireDome, Non-Catalytic, Combustion System was created specifically for the Oakwood to promote clean 

burning and even heat output. What this equates to is unvarying heat throughout your home over a longer period of time 

without the peaks and valleys of other wood stoves. The FireDome attains Harman’s reputation of high efficiency while 

saving you the expense associated with catalytic stoves. Top loading makes adding wood easier and allows you to view 

your beautiful fire through the extra large glass door. The glass stays cleaner because of specially coated glass and the 

exclusive Harman® Air Wash System.
The Harman® Oakwood has an ash pan with its own ash door that is used to remove ashes while the stove is in operation. 

This means you can keep one fire all winter if you desire. 
The Harman® Oakwood offers a cooking grill that can be placed in the top of the stove while in operation. This allows you 

to grill steaks and burgers etc. all year long, even when the weather is not suitable for outside grilling. If you haven't already 

purchased the cooking grill, you can do so through your Harman® Dealer.
Due to the fact that the Oakwood is hot while in operation, gloves should be worn while tending to the fire.

introduction

For  your  reference,  please  copy 

the serial number from the label on 

your stove to the box below.

serial nuMber

this appliance is also 

approved for installation into a 

shop.

the label shown here is for reference only

. For 

specific information on clearances and testing, 

consult the actual label on the rear of the unit.

Summary of Contents for Oakwood

Page 1: ...eau etc to determine the need for a permit Cette guide d utilisation est disponible en francais Chez votre concessionnaire de Harman home heating Model s Oakwood Cast Iron Wood Stove NOTICE SAVE THESE...

Page 2: ......

Page 3: ...eating appliance Failure to follow instructions may result in property damage bodily injury or even death Table of Contents 352 Mountain House Road Halifax PA 17032 U S A Contains updated information...

Page 4: ...ES LIBRES AUX COMBUSTIBLES A Du mur de c t l appareil 26 660mm B Du mur arri re l appareil 28 711mm C Du tuyau de chemin e au mur de c t 38 965mm D Du tuyau de chemin e au mur arri re 32 813mm E Entre...

Page 5: ...2 32 Grams Per Hour Emissions on Low 0 8 Grams Per Hour Log Length Recommended 21 Maximum BTU Hour Input 42 000 Heating Capacity 1 400 3 600 sq ft Outside Air Size 3 or 4 Inch Heating capacity to be u...

Page 6: ...wood 3 90 08327R26_03 14 SPECIFICATIONS Andirons Grate Top Load Opening Air Control Front Load Door Top Load Door Bypass Damper Control Handle Ash Door Ash Door Latch Front Load Door Latch Optional Co...

Page 7: ...fall into the ash pan by passing a poker back and forth across the grate The andirons keep the fuel from coming into direct contact with the glass and keep hot coals and embers from spilling out while...

Page 8: ...everal stages The initial or evaporation stage is where the moisture in the wood is driven off in the form of steam A second stage is where the volatile gases contained in the wood are released and bu...

Page 9: ...t finger width place several 1 2 25mm 50mm split pieces of dry wood on top of the kindling followed by a few 2 3 50 mm 80 mm split pieces Lay the wood in a crossed pattern to allow maximum air flow Ig...

Page 10: ...the bypass damper then the load door adding fuel and closing the door then the damper This depends on coal bed size load size and moisture content of fuel Removing Ashes Before reloading empty the ash...

Page 11: ...s other than those presented here INSTALLATION Parallel versus Corner Installations A parallel installation is one in which the back and sides of the stove are parallel to the walls behind and to the...

Page 12: ...12 Harman Oakwood 3 90 08327R26_03 14 INSTALLATION CLEARANCES See NFPA 211 for more installation clearance reductions when using USM wall protection etc 21 25...

Page 13: ...Harman Oakwood 13 3 90 08327R26_03 14 INSTALLATION CLEARANCES See NFPA 211 for more installation clearance reductions when using USM wall protection etc...

Page 14: ...14 Harman Oakwood 3 90 08327R26_03 14 installation clearances See NFPA 211 for more installation clearance reductions when using USM wall protection etc...

Page 15: ...es with hearth weight limitations The Oakwood should not be installed into a factory built fireplace unless the hearth area is designed to take the maximum weight of the stove The Oakwood loaded with...

Page 16: ...of space closet or other concealed space or through a floor or ceiling Whenever possible avoid passing the connector through a combustible wall if you must use an approved wall pass through described...

Page 17: ...e home installations a round flue either masonry or approved prefabricated of either 6 150 mm 7 180 mm or 8 200 mm may be used For square or rectangular masonry chimneys nominal sizes of 8 x 8 or 8 x...

Page 18: ...nry fireplace may be used to install your Oakwood In addition to the requirements found in the previous paragraphs it is important to be aware that all clearances must be met including those from the...

Page 19: ...urn up the air control lever setting and thoroughly ventilate your dwelling During future burns be careful not to overload the stove with fuel so you will not be tempted to constantly operate at a low...

Page 20: ...ilt Chimney Roof Flashing Chimney Cap Factory Built Metal Chimney Sealed Storm Collar Finishing Collar Chimney Connector Roof Radiation Shield Cathedral Style Chimney Support Chimney Cap Storm Collar...

Page 21: ...d air space Minimum of three sheet metal screws per joint of chimney connector Mantel and trim protection Airtight insulated clean out Damper closed and sealed with non combustible material Combustibl...

Page 22: ...ector Must Extend to Flue Liner Minimum 8 Masonry Thickness in Front of Smoke Chamber Use Damper Adapter or Seal with Non Combustible Material Floor Protection in Accordance with Solid Fuel Appliance...

Page 23: ...s Steel Flex Liner or Other Approved Lining System in Offsets Listed Fireplace Trim Protection for Reduced Clearance UL1777 Stainless Steel Liner System or Other approved lining system Follow liner ma...

Page 24: ...e liner with required air space Listed or approved thimble assembly 1 Clearance for exterior chimney or 2 clearance for interior chimney and 2 clearance for NFPA 211 type approved thimbles Airtight in...

Page 25: ...rfaces of the controls work the controls back and forth several times during the summer or any prolonged period when you are not using your stove The Fire Chamber The inside of the fire chamber should...

Page 26: ...ixed in place with a high temperature stove gasket cement To change a gasket first remove the worn fiberglass and clean the area with a wire brush Also clean any other surfaces that come into contact...

Page 27: ...installation the smoke deflector may not be needed on the top vent models The Cozy Screen can be used from the start of a fire or can be used with an existing one When starting a fire with the Cozy Sc...

Page 28: ...g Manufacturing date jan 2010 1 2 3 4 6 8 9 10 15 16 17 18 21 22 23 24 25 26 27 28 19 20 13 14 7 5 11 12 1 90 02490 1 black 1 90 02490 12 Forest green ending Manufacturing date jan 2010 1 90 02490 13...

Page 29: ...per Elbow Painted 3 50 00500S Y 7 Cook Grill Assembly Optional 1 00 08121 8 Flue Collar 4 00 249108D 9 Top Hinge Plate Qty 2 req 2 00 249147S 10 Top 4 00 249105P Gasket 30 Ft 1 00 00888 Y 11 Top Load...

Page 30: ...249188L 22 Ash Pan 1 10 249151 Y 23 Steel Ash Box Weldment 1 10 249144S 24 Ca Shield 2 00 249157B 25 Leg Qty 4 req 4 00 249100P Y 26 Bottom 4 00 249104D 27 Right Side Panel 4 00 249102D 28 Damper Fra...

Page 31: ...9117A Y 32 8 Grate 2 00 249122 Y 32 9 Cast Right Inside Plate w Gasket 1 10 249118A Y 32 10 Rear Brick Retainer Pkg of 2 1 00 249135 32 11 Shoe Brick 3 40 00100 Y Gasket shoe Brick 10 Ft 1 00 11862 Y...

Page 32: ...nty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty...

Page 33: ...cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is no...

Page 34: ...34 Harman Oakwood Date Of Service Performed By Description Of Service 3 90 08327R26_03 14 service maintenance log...

Page 35: ...35 Harman Oakwood 3 90 08327R26_03 14 NOTES...

Page 36: ...e This powerful heating appliance boasts uncompromising attention to detail and helps preserve our planet by using environmentally responsible fuels Signature of Boxer Your premium quality hearth prod...

Reviews: