4
Harman Oakwood
3-90-08327R26_03/14
Harman Oakwood Wood Stove
Label Measures: 7" high X 7.75" wide
BARCODE LABEL
008
Serial No.
N
o
de série:
CAUTION
: HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP
CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS.
SEE NAMEPLATE AND INSTRUCTIONS. KEEP FURNISHINGS AND OTHER
COMBUSTIBLE MATERIALS A CONSIDERABLE DISTANCE AWAY FROM
THIS APPLIANCE.
ATTENTION
: CHAUD-NE PAS TOUCHER. TENIR LES ENFANTS
ET LES VENTEMENTS A L’ECART. RISQUE DE BRULURE. VOIR
INSTRUCTIONS SUR LA PLAQUE. LAISSER UNE DISTANCE SUFFISANTE
ENTRE L’APPAREIL ET LES MEUBLESOU AUTRES OBJECT A RISQUE.
PREVENT HOUSE FIRES:
Install and use only in accordance with manufacturer’s installation and operation instructions and local
building codes. In absence of any local codes, installation must meet minimum requirements of NFPA 211
in USA. Refer to manufacturer’s instructions and local codes for precautions required for passing chimney
through a combustible wall or ceiling.
FOR USE WITH SOLID WOOD FUEL ONLY.
Don’t connect this stove to a chimney serving another appliance.
Flue connector pipe must be 6” diameter, minimum 24 MSG black or 26 MSG blue steel.
Chimney must be factory built UL 103HT or masonry.
NOTE:
Replace glass only with 5mm ceramic glass available from your dealer.
Inspect and clean chimney frequently. Under certain conditions of use, creosote buildup may occur rapidly.
DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR GLOWS, YOU ARE OVERFIRING.
DO NOT obstruct the space beneath the appliance.
LISTED SOLID FUEL FIREPLACE STOVE OR ROOM HEATER/
APPAREIL DE CHAUFFAGE OU POELE A COMBUSTIBLE SOLIDE
MODEL/Modèle: OAKWOOD
CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA/
CONTACTEZ LE BUREAU DE LA CONSTRUCTION OU LE BUREAU DES INCENDIES AU DES RESTRICTIONS ET DE L’INSPECTION
D’INSTALLATION DANS VOTRE VOISINAGE
PRéVENTION DES INCENDIES:
Respectez scrupuleusement les instructions du constructeur pour l’installation et l’utilisation. Respectez
les règles et normes applicables dans votre région. Dans tous les cas, l’installation devra au minimum
satisfaire aux exigences de NFPA 211 AUX Etats-Unis.
Reportez vous aux instructions du fabricant et aux règles locales pour les précautions nécessaires lors
du passage des tuyaux de fumée à travers un mur ou un plafond combustible. contrôlez et nettoyez
fréquemment la cheminée et les tuyaux de fumée selon les instructions du fabricant.
N’UTILISEZ QUE DU BOIS EN BUCHES:
Ne pas raccorder ce poêle à un conduit de fumée utilisé pour un autre appareil.
Le tuyau de fumée doit avoir 6” de diamètre minimum, et être en acier de qualité 24MSG noir ou 26
MSG bleu.
La conduit de fumée peut être maçonné ou de fabrication industrielle type ULC S629.
Nota:
Ne remplacer la vitre qu’avec une vitre céramique de 45 mm disponible chez votre fournisseur.
Contrôlez et nettoyez fréquemment la cheminée et les tuyaux de fumée. Dans certaines conditions
d’utilisation, des accumulations de créosote peuvent se produire rapidement.
NE PAS SUR CHAUFFER - SI LE POELE OU LE TUYAU ROUGISSENT, VOUS SURCHAUFFEZ!
Ne pas obstruer l’espace en dessous du bruleur.
CLEARANCE TO COMBUSTIBLE SURFACE
A - Unit to Side Wall
26” (660mm)
B - Unit to Back Wall
28” (711mm)
C - Chimney Connector to Side Wall 38” (965mm)
D - Chimney Connector to Back Wall 32” (813mm)
E - Unit to Adjacent wall
24” (610mm)
F -
Chimney Connector to Adjacent wall
32” (813mm)
*See manual for additional installation configurations.
ESPACES LIBRES AUX COMBUSTIBLES
A - Du mur de côté à l’appareil 26” (660mm)
B - Du mur arrière àl’appareil 28” (711mm)
C - Du tuyau de cheminée au mur de côté 38” (965mm)
D - Du tuyau de cheminée au mur arrière 32” (813mm)
E - Entre le mur adjacent et l’appareil 24” (610mm)
F - Entre la tuyau et le mur adjacent 32” (813mm)
* Voir le manuel pour d’autres configurations d’installation
Floor protection must be a 3/4” min. thickness, non-combustible
material having an equal or better insulating value (lower k
value) of k=.84 BTU/In Ft
2
Hr °F, extending beneath heater
and to front/sides/rear as indicated. In Canada, required floor
protection must be 18” (450mm) in front.
Leprotecteur de plancher doit être d’une epaisseur minimum de
3/4” d’un material incombustible ayant une valeur d’isolation de
k=.84 BTU/in Ft
2
Hr °F.
Il doit s’etendre et à l’arriêre de l’appareil comme indiquè.
‘Au Canada, la preotection du plancher doit s’étendre de 18”
(450mm) en avant.
Manufactured by/Fabriqué par: Hearth and Home Technologies
352 Mountain House Road
Halifax, Pa 17032
2013 2014 2015 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
U.S. ENVIROMENTAL PROTECTION AGENCY
CERTIFIED TO COMPLY WITH JULY 1990 PARTICULATE EMISSIONS STANDARD
Date of Manufacture / Date de fabrication
Rev C
P.N. 3-90-249
BACKWALL
SIDE
W
ALL
A
C
B
D
ADJACENT WALL
ADJA
CENT W
ALL
E
F
8”
8”
8”
16”
BACKWALL
SIDE
W
ALL
A
C
B
D
ADJACENT WALL
ADJA
CENT W
ALL
E
F
8”
8”
8”
16”
FLOOR PROTECTOR
FRONT
BACKWALL
SIDE
W
ALL
A
C
B
D
ADJACENT WALL
ADJA
CENT W
ALL
E
F
8”
8”
8”
16”
Tests réalisés par OMNI-Test Laboratories, Inc.
Report #/Rapport #135-S-11-2
Tested to/Testé selon: August 2002, UL 1482-1996,
UL 737-1996 and ULC-S627-00
Certified for U.S.A. and Canada/Certifié pour les
états-Unis et le Canada
Thank you for purchasing the Harman® Oakwood. We are confident that you will enjoy the warmth and convenience of your
Harman® Stove for decades to come.
The Harman® Oakwood will heat your home while also being multi-functional and visually appealing. When building your
Oakwood, we used only the best precision castings that were designed, so accurately, that gaskets are used (instead of
furnace cement) for assembly.
Harman’s special FireDome, Non-Catalytic, Combustion System was created specifically for the Oakwood to promote clean
burning and even heat output. What this equates to is unvarying heat throughout your home over a longer period of time
without the peaks and valleys of other wood stoves. The FireDome attains Harman’s reputation of high efficiency while
saving you the expense associated with catalytic stoves. Top loading makes adding wood easier and allows you to view
your beautiful fire through the extra large glass door. The glass stays cleaner because of specially coated glass and the
exclusive Harman® Air Wash System.
The Harman® Oakwood has an ash pan with its own ash door that is used to remove ashes while the stove is in operation.
This means you can keep one fire all winter if you desire.
The Harman® Oakwood offers a cooking grill that can be placed in the top of the stove while in operation. This allows you
to grill steaks and burgers etc. all year long, even when the weather is not suitable for outside grilling. If you haven't already
purchased the cooking grill, you can do so through your Harman® Dealer.
Due to the fact that the Oakwood is hot while in operation, gloves should be worn while tending to the fire.
introduction
For your reference, please copy
the serial number from the label on
your stove to the box below.
serial nuMber
this appliance is also
approved for installation into a
shop.
the label shown here is for reference only
. For
specific information on clearances and testing,
consult the actual label on the rear of the unit.