Stub Mounting Bolts
Intake Stub
Stub Gasket
Self-drilling screws (2)
Outside Air Intake Weldment
D. Outside Air
The outside air kit consists of a Intake Stub, Stub Gasket,
Outside Air intake Weldment and hardware. Figure 4.7.
An adjustable chimney intake extension, part #1-00-674104
is available to be used on masonry chimneys only. Figure 4.8.
Additional information and diagrams can be found under the
“Venting
Termination Design” section of the manual
.
To install outside air, use kit part #1-00-774280. Follow the
installation instructions provided with the kit.
100% Outside Air Kit - #1-00-774280
Figure 4.7
E. Locating Your Appliance & Chimney
Location of the appliance and chimney will affect performance.
• Install through the warm airspace enclosed by the building
envelope. This helps to produce more draft, especially
during lighting and die-down of the fire.
• Penetrate the highest part of the roof. This minimizes the
effects of wind loading.
• Locate termination cap away from trees, adjacent
structures, uneven roof lines and other obstructions.
• Minimize the use of chimney offsets.
• Consider the appliance location relative to floor and ceiling
and attic joists.
Chimney cap and flex termination with
flashing plate (by installer) THIS CAP
MUST BE Stainless Steel
With the intake assenbly anchored into
place, finish the 4” SS flex liner and cap
(by installer) by screwing the cap’s flashing
plate to the top of the intake assenbly.
A waterproofing sealant can be used to
seal the corners and irregularities in the top
of the masonry chimney.
After adjusting the intake assembly
for the flue size, secure the
assembly to the top of the chimney
with some form of anchors or
screws.
Masonry Flue Liner
Masonry Chimney
Adjustable Chimney Intake Extension Part # 1-00-674104
Figure 4.8
18 1/8”
18 1/8”
18”
18”
22 1/8”
18”
22 1/8”
4”
6”
1”
Harman® SS Chimney Top Intake Assembly
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVICING ANOTHER APPLIANCE.
• DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT
OR SYSTEM.
May allow flue gases to enter the house
CAUTION
!