Harman®  •  P43 Installation Manual_R23  •  2008 -___  •  04/14

22

3-90-04301i

Reference Material 

 

When  installing  and  operating  your  Harman®  P43, 

respect basic safety standards. Read these instructions 

carefully before you attempt to install or operate the 

P43. Failure to do so may result in damage to property 

or personal injury and  may void the product warranty.
Consult  with  your  local  building  code  agency  and 

insurance  representative  before  you  begin  your 

installation  to  ensure  compliance  with  local  codes, 

including the need for permits and follow-up inspections.

A. Safety Reminders

WARNING

!

MOBILE/MANUFACTURED HOME GUIDELINES 

DO NOT ALLOw INSTALLATION IN A SLEEPING 

ROOM.

WARNING

!

KEEP COMBUSTIBLE MATERIALS SUCH AS 

GRASS, LEAVES, ETC. AT LEAST 3 FEET AwAY 

FROM THE POINT DIRECTLY UNDER THE VENT 

TERMINATION.

WARNING

!

USE OF IMPROPER FUELS, FIRE STARTERS 

OR ALTERING THE STOVE FOR HIGHER HEAT 

OUTPUT MAY CAUSE DAMAGE TO THE STOVE 

AND COULD RESULT IN A HOUSE FIRE. USE 

ONLY APPROVED FUELS AND OPERATION 

GUIDELINES

THE STOVE IS HOT wHILE IN OPERATION.
KEEP CHILDREN, CLOTHING AND FURNITURE 

AwAY.  CONTACT MAY CAUSE SKIN BURNS.

CAUTION

!

THE STRUCTURAL INTEGRITY OF THE MOBILE 

HOME FLOOR, wALL, AND CEILING/ROOF MUST 

BE MAINTAINED.

CAUTION

!

Due to high temperatures, this stove should be placed 

out of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazards 

of high surface temperatures and should stay away  to 

avoid burn to skin and/or clothing.
Young children should be carefully supervised when 

they are in  the same room as the stove.
Clothing and other flammable materials should not be 

placed on or near this stove.
Installation  and  repair  of  this  stove  should  be  done 

by  a  qualified  service  person. The  appliance  should 

be  inspected  before  use  and  at  least  annually  by  a 

qualified service person. More frequent cleaning may 

be required. It is imperative that control compartments, 

burners, and circulating air passageways of this stove 

be kept clean.

CAUTION

!

This appliance must be vented to the outside.

Summary of Contents for P43

Page 1: ...with local regional state and national codes and regulations Contact local building or fire officials about restrictions and installation inspection requirements in your area Tested and approved for...

Page 2: ...tions 4 E Non Combustible Materials Specification 4 F Combustible Materials Specification 4 G Electrical Codes 4 2 Getting Started A Design and Installation Considerations 5 B Tools and Supplies Neede...

Page 3: ...l roof flashing installed and sealed ________________________________ Terminations installed and sealed ________________________________ Electrical Section 1 Pg 4 120VAC unswitched power provided to t...

Page 4: ...will be voided by the below actions DO NOT Install or operate damaged appliance Modify appliance Install other than as instructed by Hearth Home Technologies Operate the appliance without fully assemb...

Page 5: ...vent termination CAUTION If burning shelled field corn you must use approved venting specifically designed for corn to prevent corrosion or degradation Follow the instructions from the venting manufa...

Page 6: ...installation Follow these instructions carefully during the installation to ensure maximum safety and benefit WARNING Risk of Fire or Explosion Damaged parts could impair safe operation DO NOT instal...

Page 7: ...n Manual_R23 2008 ___ 04 14 7 3 90 04301i 20 3 4 22 10 33 1 2 5 1 8 13 3 4 28 5 16 3 Clearances Figure 3 1 A Appliance Dimension Diagram Dimensions are actual appliance dimensions Use for reference on...

Page 8: ...to consider the required clearances to walls see Figure 3 2 Figure 3 2 10 254mm with side shields 16 406mm without side shields 2 51mm 36 914mm 10 254mm 16 406mm 9 228mm With or Without Side Shields...

Page 9: ...e pipe The minimum floor protector material is 20 gauge sheet metal Other floor protector materials are ceramic tile stone brick etc Figure 3 3 NOTE for Canadian installation only Per ULC S627 00 If i...

Page 10: ...wall pass through 2 Preferred method Figure 4 2 This method also provides excellent venting for normal operation but requires the stove to be installed farther from the wall The vertical portion of t...

Page 11: ...ting fireplace chimney Figure 4 4 This method provides excellent venting for normal operation This method also provides natural draft in the event of a power failure If the chimney condition is questi...

Page 12: ...ent pipe fittings Seal pipe joints with silicone or aluminum tape in addition to the sealing system used by the manufacturer Pipe size should be increased to 4 using this method 6 Installing into an e...

Page 13: ...ed by the manufacturer Note Do not place joints within wall pass through Figure 4 7 Figure 4 8 Figure 4 9 Area within dotted circle represents the minimum clearance to combustible materials such as sh...

Page 14: ...is fully open on a minimum of 2 sides beneath the floor NOTE Where passage through a wall or partition of combustible construction is desired the installation shall conform to CAN CSA B365 if in Canad...

Page 15: ...ical from the flue stub may require more frequent cleaning due to fly ash falling off inside and collecting directly above the combustion blower outlet Any use of horizontal venting will require more...

Page 16: ...liance but consideration must be given to the total house demand House demand may consume some air needed for the stove especially during a power failure It may be necessary to add additional ventilat...

Page 17: ...he flue pipe connect a draft meter The draft meter must have a minimum range of 0 5 Record the first reading Connect flue pipe to stove and be sure all doors and windows in the home are closed Record...

Page 18: ...mends Installing the pellet vent with a minimum vertical run of five feet preferably terminating above the roof line Installing the outside air intake at least four feet below the vent termination To...

Page 19: ...tend with small fires In the event of a hopper fire Evacuate the house immediately Notify fire department J Inspect Appliance Components Remove appliance and components from packaging and inspect for...

Page 20: ...l sides of the burn pot and that the back of the guide rests against the body of the stove Figure 5 3 INSTALL EXHAUST VENT AT CLEARANCES SPECIFIED BY THE MANUFACTURER Most pellet vent pipe requires a...

Page 21: ...nt should be done by the installer during set up because a draft meter reading is required to insure proper set up Combustion Motor Speed Control Low draft only set point The small straight screwdrive...

Page 22: ...stove and could result in a House fire Use only approved fuels and operation guidelines The stove is hot while in operation Keep children clothing and furniture away Contact may cause skin burns CAUT...

Page 23: ...ONTACTS N O MALE FEMALE CONNECTIONS BONDED TO STOVE BODY GREEN WIRE IS GROUND P O W E R C O R D 1 8 3 R U B B E R C O R D WHITE GREEN BLUE GREEN WHITE RED MALE FEMALE CONNECTIONS BROWN WHITE MALE FEMA...

Page 24: ...U S A Copyright 2012 Harman a brand of Hearth Home Technologies Inc 352 Mountain House Road Halifax PA 17032 www harmanstoves com Please contact your Harman dealer with any questions or concerns For t...

Reviews: