background image

Harman®  •  P43 Installation Manual_R23  •  2008 -___  •  04/14

3

3-90-04301i

Installation Standard work Checklist

ATTENTION INSTALLER:

Follow this Standard Work Checklist

This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in 

this installation manual.

Customer: 

________________________________ 

 Date 

Installed: 

 __________________________

Lot/Address:  ________________________________  

Location of Stove: 

__________________________

  ________________________________ 

 Installer:  __________________________

 

Model: ________________________________  

Dealer/Distributer Ph # __________________________

        Serial 

Number: 

 __________________________

!

WARNING! Risk of Fire or Explosion! Failure to install appliance to these instructions can lead 

to a fire or explosion.

Appliance Install 

      YES 

 IF 

NO, 

wHY?

Required non-combustible floor protection 

(Pg. 9)   

 

 

________________________________

Verified clearances to combustible. 

 

(Pg. 10-14) 

 

 

________________________________

Unit is Leveled and secured. 

 

 

 

 

 

 

________________________________

Venting/Chimney Section 4 (Pg. 10-19)

Venting Configuration complies to vent diagrams. 

 

 

 

________________________________

Venting installed, sealed and secured in place with proper clearances.   

________________________________

Exterior wall/roof flashing installed and sealed   

 

 

 

________________________________

Terminations installed and sealed. 

 

 

 

 

 

________________________________

Electrical Section 1 (Pg. 4)

120VAC unswitched power provided to the appliance.   

 

 

________________________________

Appliance Setup Section 5 (Pg. 20-21)

All packaging and protective materials are removed 

 

 

 

________________________________

Accessories installed properly   

 

 

 

 

 

________________________________

Manual bag and all it’s contents are removed from inside the appliance

 

and given to party responsible for use and operation 

 

 

________________________________

Started appliance and verified that all motors and blowers operate

 

as they should.   

 

 

 

 

 

 

________________________________

Hearth and Home Technologies recommends the following:

Photographing the installation and copying this checklist for your file.

This checklist remain visible at all times on the appliance until the installation is complete.

Comments: Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action 

needed __________________________________________________________________________________________
_________________________________________________________________________________________________
_________________________________________________________________________________________________
Comments communicated to party responsible____________________ by ________________________ on __________
 

 

 

 

 

          (Builder / Gen Contractor)    (Installer) 

 

 

     (Date)

Summary of Contents for P43

Page 1: ...with local regional state and national codes and regulations Contact local building or fire officials about restrictions and installation inspection requirements in your area Tested and approved for...

Page 2: ...tions 4 E Non Combustible Materials Specification 4 F Combustible Materials Specification 4 G Electrical Codes 4 2 Getting Started A Design and Installation Considerations 5 B Tools and Supplies Neede...

Page 3: ...l roof flashing installed and sealed ________________________________ Terminations installed and sealed ________________________________ Electrical Section 1 Pg 4 120VAC unswitched power provided to t...

Page 4: ...will be voided by the below actions DO NOT Install or operate damaged appliance Modify appliance Install other than as instructed by Hearth Home Technologies Operate the appliance without fully assemb...

Page 5: ...vent termination CAUTION If burning shelled field corn you must use approved venting specifically designed for corn to prevent corrosion or degradation Follow the instructions from the venting manufa...

Page 6: ...installation Follow these instructions carefully during the installation to ensure maximum safety and benefit WARNING Risk of Fire or Explosion Damaged parts could impair safe operation DO NOT instal...

Page 7: ...n Manual_R23 2008 ___ 04 14 7 3 90 04301i 20 3 4 22 10 33 1 2 5 1 8 13 3 4 28 5 16 3 Clearances Figure 3 1 A Appliance Dimension Diagram Dimensions are actual appliance dimensions Use for reference on...

Page 8: ...to consider the required clearances to walls see Figure 3 2 Figure 3 2 10 254mm with side shields 16 406mm without side shields 2 51mm 36 914mm 10 254mm 16 406mm 9 228mm With or Without Side Shields...

Page 9: ...e pipe The minimum floor protector material is 20 gauge sheet metal Other floor protector materials are ceramic tile stone brick etc Figure 3 3 NOTE for Canadian installation only Per ULC S627 00 If i...

Page 10: ...wall pass through 2 Preferred method Figure 4 2 This method also provides excellent venting for normal operation but requires the stove to be installed farther from the wall The vertical portion of t...

Page 11: ...ting fireplace chimney Figure 4 4 This method provides excellent venting for normal operation This method also provides natural draft in the event of a power failure If the chimney condition is questi...

Page 12: ...ent pipe fittings Seal pipe joints with silicone or aluminum tape in addition to the sealing system used by the manufacturer Pipe size should be increased to 4 using this method 6 Installing into an e...

Page 13: ...ed by the manufacturer Note Do not place joints within wall pass through Figure 4 7 Figure 4 8 Figure 4 9 Area within dotted circle represents the minimum clearance to combustible materials such as sh...

Page 14: ...is fully open on a minimum of 2 sides beneath the floor NOTE Where passage through a wall or partition of combustible construction is desired the installation shall conform to CAN CSA B365 if in Canad...

Page 15: ...ical from the flue stub may require more frequent cleaning due to fly ash falling off inside and collecting directly above the combustion blower outlet Any use of horizontal venting will require more...

Page 16: ...liance but consideration must be given to the total house demand House demand may consume some air needed for the stove especially during a power failure It may be necessary to add additional ventilat...

Page 17: ...he flue pipe connect a draft meter The draft meter must have a minimum range of 0 5 Record the first reading Connect flue pipe to stove and be sure all doors and windows in the home are closed Record...

Page 18: ...mends Installing the pellet vent with a minimum vertical run of five feet preferably terminating above the roof line Installing the outside air intake at least four feet below the vent termination To...

Page 19: ...tend with small fires In the event of a hopper fire Evacuate the house immediately Notify fire department J Inspect Appliance Components Remove appliance and components from packaging and inspect for...

Page 20: ...l sides of the burn pot and that the back of the guide rests against the body of the stove Figure 5 3 INSTALL EXHAUST VENT AT CLEARANCES SPECIFIED BY THE MANUFACTURER Most pellet vent pipe requires a...

Page 21: ...nt should be done by the installer during set up because a draft meter reading is required to insure proper set up Combustion Motor Speed Control Low draft only set point The small straight screwdrive...

Page 22: ...stove and could result in a House fire Use only approved fuels and operation guidelines The stove is hot while in operation Keep children clothing and furniture away Contact may cause skin burns CAUT...

Page 23: ...ONTACTS N O MALE FEMALE CONNECTIONS BONDED TO STOVE BODY GREEN WIRE IS GROUND P O W E R C O R D 1 8 3 R U B B E R C O R D WHITE GREEN BLUE GREEN WHITE RED MALE FEMALE CONNECTIONS BROWN WHITE MALE FEMA...

Page 24: ...U S A Copyright 2012 Harman a brand of Hearth Home Technologies Inc 352 Mountain House Road Halifax PA 17032 www harmanstoves com Please contact your Harman dealer with any questions or concerns For t...

Reviews: