Harman®  •  P43 Installation Manual_R23  •  2008 -___  •  04/14

5

3-90-04301i

Warning! Risk of Fire

 

Damaged parts could impair safe operation. 

Do NOT install damaged, incomplete or substitute components. 

A.  Design and Installation Considerations

1. Appliance Location

NOTICE: 

Check building codes prior to installation.

•  Installation MUST comply with local, regional, state and 

national codes and regulations.

•  Consult  insurance  carrier,  local  building  inspector,  fire 

officials or authorities having jurisdiction over restrictions, 

installation inspection and permits.

It is a good idea to plan your installation on paper, using exact 

measurements for clearances and floor protection, before 

actually beginning the installation
Consideration must be given to:
•  Safety, convenience, traffic flow
•  Placement of the chimney and chimney connector.  
•  If  you  are  not  using  an  existing  chimney,  place  the 

appliance  where  there  will  be  a  clear  passage  for  a 

factory-built listed chimney through the ceiling and roof.  

•  Installing  an  optional  outside  air  kit  would  affect  the 

location of the vent termination.

CAUTION!

  

If  burning  shelled  field  corn,  you  must  use 

approved venting specifically designed for corn to prevent 

corrosion or degradation. Follow the instructions from the 

venting manufacturer.

NOTICE:  

Locating the appliance in a location of considerable 

air movement can cause intermittent smoke spillage from 

appliance. Do not locate appliance near:
•  Frequently open doors
•  Central heat outlets or returns

Marginal Location:

•  Below peak

Location NOT recommended:

•  Not the highest point of the roof

•  Wind loading possible

Multi-level Roofs

Windward 

Leeward

Recommended:

Outside Air Intake

on windward side

NOT recommended:

Outside Air Intake

on leeward side

Recommended Location:

•  Above peak

Recommended:

•  Insulated exterior chase 

in cooler climates

Recommended Location:

•  Above peak

•  Inside heated space

Location NOT recommended:

•  Too close to tree

•  Below adjacent structure

•  Lower roof line

•  Avoid outside wall

Marginal Location:

•  Wind loading possible

Figure 2.1

Getting Started 

Since pellet exhaust can contain ash, soot or sparks, you 

must consider the location of:
•  Windows
•  Air Intakes
•  Air Conditioner
•  Overhang, soffits, porch roofs, adjacent walls 
•  Landscaping, vegetation
When  locating  vent  and  venting  termination,  vent  above 

roof line when possible.

Summary of Contents for P43

Page 1: ...with local regional state and national codes and regulations Contact local building or fire officials about restrictions and installation inspection requirements in your area Tested and approved for...

Page 2: ...tions 4 E Non Combustible Materials Specification 4 F Combustible Materials Specification 4 G Electrical Codes 4 2 Getting Started A Design and Installation Considerations 5 B Tools and Supplies Neede...

Page 3: ...l roof flashing installed and sealed ________________________________ Terminations installed and sealed ________________________________ Electrical Section 1 Pg 4 120VAC unswitched power provided to t...

Page 4: ...will be voided by the below actions DO NOT Install or operate damaged appliance Modify appliance Install other than as instructed by Hearth Home Technologies Operate the appliance without fully assemb...

Page 5: ...vent termination CAUTION If burning shelled field corn you must use approved venting specifically designed for corn to prevent corrosion or degradation Follow the instructions from the venting manufa...

Page 6: ...installation Follow these instructions carefully during the installation to ensure maximum safety and benefit WARNING Risk of Fire or Explosion Damaged parts could impair safe operation DO NOT instal...

Page 7: ...n Manual_R23 2008 ___ 04 14 7 3 90 04301i 20 3 4 22 10 33 1 2 5 1 8 13 3 4 28 5 16 3 Clearances Figure 3 1 A Appliance Dimension Diagram Dimensions are actual appliance dimensions Use for reference on...

Page 8: ...to consider the required clearances to walls see Figure 3 2 Figure 3 2 10 254mm with side shields 16 406mm without side shields 2 51mm 36 914mm 10 254mm 16 406mm 9 228mm With or Without Side Shields...

Page 9: ...e pipe The minimum floor protector material is 20 gauge sheet metal Other floor protector materials are ceramic tile stone brick etc Figure 3 3 NOTE for Canadian installation only Per ULC S627 00 If i...

Page 10: ...wall pass through 2 Preferred method Figure 4 2 This method also provides excellent venting for normal operation but requires the stove to be installed farther from the wall The vertical portion of t...

Page 11: ...ting fireplace chimney Figure 4 4 This method provides excellent venting for normal operation This method also provides natural draft in the event of a power failure If the chimney condition is questi...

Page 12: ...ent pipe fittings Seal pipe joints with silicone or aluminum tape in addition to the sealing system used by the manufacturer Pipe size should be increased to 4 using this method 6 Installing into an e...

Page 13: ...ed by the manufacturer Note Do not place joints within wall pass through Figure 4 7 Figure 4 8 Figure 4 9 Area within dotted circle represents the minimum clearance to combustible materials such as sh...

Page 14: ...is fully open on a minimum of 2 sides beneath the floor NOTE Where passage through a wall or partition of combustible construction is desired the installation shall conform to CAN CSA B365 if in Canad...

Page 15: ...ical from the flue stub may require more frequent cleaning due to fly ash falling off inside and collecting directly above the combustion blower outlet Any use of horizontal venting will require more...

Page 16: ...liance but consideration must be given to the total house demand House demand may consume some air needed for the stove especially during a power failure It may be necessary to add additional ventilat...

Page 17: ...he flue pipe connect a draft meter The draft meter must have a minimum range of 0 5 Record the first reading Connect flue pipe to stove and be sure all doors and windows in the home are closed Record...

Page 18: ...mends Installing the pellet vent with a minimum vertical run of five feet preferably terminating above the roof line Installing the outside air intake at least four feet below the vent termination To...

Page 19: ...tend with small fires In the event of a hopper fire Evacuate the house immediately Notify fire department J Inspect Appliance Components Remove appliance and components from packaging and inspect for...

Page 20: ...l sides of the burn pot and that the back of the guide rests against the body of the stove Figure 5 3 INSTALL EXHAUST VENT AT CLEARANCES SPECIFIED BY THE MANUFACTURER Most pellet vent pipe requires a...

Page 21: ...nt should be done by the installer during set up because a draft meter reading is required to insure proper set up Combustion Motor Speed Control Low draft only set point The small straight screwdrive...

Page 22: ...stove and could result in a House fire Use only approved fuels and operation guidelines The stove is hot while in operation Keep children clothing and furniture away Contact may cause skin burns CAUT...

Page 23: ...ONTACTS N O MALE FEMALE CONNECTIONS BONDED TO STOVE BODY GREEN WIRE IS GROUND P O W E R C O R D 1 8 3 R U B B E R C O R D WHITE GREEN BLUE GREEN WHITE RED MALE FEMALE CONNECTIONS BROWN WHITE MALE FEMA...

Page 24: ...U S A Copyright 2012 Harman a brand of Hearth Home Technologies Inc 352 Mountain House Road Halifax PA 17032 www harmanstoves com Please contact your Harman dealer with any questions or concerns For t...

Reviews: