Harman® • P-Series Owner’s Manual_R10 • 2014 - ___ • 11/15
6
3-90-436168c
2
Product Specific and Important Safety Information
A. Appliance Certification
The P43, P61A and P68 are Certified to
comply with 2015 particulate emission
standards. Not approved for sale after
May 15, 2020.
C. Glass Specifications
This appliance is equipped with 5mm mirrored ceramic
glass. Replace glass only with 5mm ceramic glass. Please
contact your dealer for replacement glass.
D. Electrical Rating
120 VAC, 60 Hz, Start 4.2 Amps, Run 2.8 Amps
NOTE: Some generator or battery back-up systems may
not be compatible with the micro-processor electronics
on this appliance. Please consult the power supply
manufacturer for compatible systems.
T H E S T R U C T U R A L I N T E G R I T Y O F T H E
MANUFACTURED HOME FLOOR, WALL, AND
CEILING/ROOF MUST BE MAINTAINED.
DO NOT INSTALL IN SLEEPING ROOM.
WARNING
!
NOTE:
This installation must conform with local codes.
In the absence of local codes you must comply with
the
ASTM E1509-2004, ULC-S627-00, ULC/ORD-C-
1482-M1990, (UM) 84-HUD
MODEL:
P43 Pellet Stove
LABORATORY:
OMNI Test Laboratories, Inc
REPORT NO.
135-S-23-4, 135-S-23b-6.2
TYPE:
Pellet Fueled/Supplementary For
Residential Use
STANDARD(s):
ASTM E 1509-04, ULC/ORD-
C1482-M1990, ULC-S627-00, EPA
Method 28 & 5G
MODEL:
P61A Pellet Stove
LABORATORY:
OMNI Test Laboratories, Inc
REPORT NO.
135-S-22-4, 135-S-22b-6.2
TYPE:
Pellet Fueled/Supplementary For
Residential Use
STANDARD(s):
ASTM E 1509-04, ULC/ORD-
C1482-M1990, ULC-S627-00, EPA
Method 28 & 5G
MODEL:
P68 Pellet Stove
LABORATORY:
OMNI Test Laboratories, Inc
REPORT NO.
135-S-13-2, 135-S-13b-2,
135-S-13c-6.2
TYPE:
Pellet Fueled/Supplementary For
Residential Use
STANDARD(s):
ASTM E 1509-04, ULC/ORD-
C1482-M1990, ULC-S627-00, EPA
Method 28 & 5G
B. Mobile Home Approved
This appliance is approved for mobile home installations
when not installed in a sleeping room and when an outside
combustion air inlet is provided.
The structural integrity of the mobile home floor, ceiling, and
walls must be maintained. The appliance must be properly
grounded to the frame of the mobile home and use only listed
pellet vent, Class “PL” connector pipe.
A Harman
®
Outside Air Kit must be installed in a mobile home
installation.