background image

Harman®  •  P-Series Owner’s Manual_R23  •  2014 - ___  •  02/19

2

3-90-436168c

Listing Label Information/Location

A. Congratulations

Congratulations on selecting a Harman

®

 Freestanding Pellet 

Stove. The Harman

®

 P-Series pellet stove you have selected 

is designed to provide the utmost in safety, reliability, and 

efficiency.

As the owner of a new pellet stove, you’ll want to read and 

carefully follow all of the instructions contained in this owner’s 

manual. Pay special attention to all cautions and warnings.

This owner’s manual

 

should be retained for future reference. 

We suggest that you keep it with your other important 

documents and product manuals.
Your new Harman

®

 P-Series Freestanding Pellet Stove will 

give you years of durable use and trouble-free enjoyment. 

Welcome to the Harman

®

 family!

The model information regarding your specific stove can be found on 

the rating plate usually located in the control area of the stove.

Read this manual before operating this appliance. 

Please retain this Owner’s Manual for future reference.

Read the Installation Manual before making any installation or finishing changes.

Welcome  

Brand: ________________________________________________ Model Name: ___________________________

Serial Number: __________________________________________ Date Installed: __________________________

Appliance Information:

Local Dealer Information

DEALER:

 

Fill in 

your name, address, 

phone and email 

information here and 

appliance information 

below.

Dealer Name: ________________________________________________________

Address: ____________________________________________________________

               ____________________________________________________________

Phone:   _____________________________________________________________

Email:    _____________________________________________________________

Report #/ Rapport #135-S-22-4, 135-S-22b-6.2

Tested to / Testé à: ASTM E 1509-04, ULC/ORD-

C1482-M1990, ULC-S627-00, EPA Method 28 & 5G

Chauffe-chambre, Pellet à combustibles Type, également pour les maisons mobiles. (UM) 84-HUD

“EMPÊCHER MAISON INCENDIES”

 Installer et utiliser uniquement en conformité avec les instructions 

du fabricant d’installation et d’exploitation.

Ce poêle à bois doit inspection périodique et la réparation pour un fonctionnement correct. Consultez le 

manuel du propriétaire pour plus d’informations. Ce est contre les règlements fédéraux pour faire fonctionner 

ce poêle à bois d’une manière incompatible avec les instructions d’utilisation dans le manuel du propriétaire.

Contactez le service des incendies à propos des restrictions et l’inspection d’installation dans votre région.

AVERTISSEMENT: POUR MAISONS PRÉFABRIQUÉES:

 Ne pas installer l’appareil dans une chambre à 

coucher. Une entrée d’air de combustion à l’extérieur doit être fournie. L’intégrité structurale de la maison 

étage, plafond et murs fabriqués doit être maintenue.

Reportez-vous aux instructions du fabricant et les codes locaux pour les précautions nécessaires pour 

faire passer la cheminée à travers un mur ou un plafond combustible. Inspectez et nettoyez système 

d’évacuation souvent en conformité avec les instructions du fabricant.

Utilisez un “ou 4” Type de diamètre «L» 3 ou le système de ventilation “PL”.

Ne pas connecter cet appareil à un conduit de cheminée desservant un autre appareil.

Ne pas obstruer l’espace sous le chauffe-eau.

À UTILISER AVEC LA GRANULE DE BOIS SEULEMENT..

Entrée Max Note: £ 7,1 carburant / h

Émissions certifiés EPA: 1,7 g / h

US Note électrique: 115 VAC, 60 Hz, Start 4,2 AMPS, Run 2,8 AMPS

Type de carburant: granulés de bois.

Route cordon électrique de l’appareil.

Fonctionner uniquement avec les portes fermées

DANGER:

 Risque de choc électrique. Débranchez l’alimentation avant l’Unité des services.

Pour de plus amples instructions, reportez-vous à l’installation et le manuel du propriétaire.

Remplacer le verre seulement avec 5mm miroir en céramique disponibles chez votre revendeur.

Ne ENLEVEZ PAS CETTE ÉTIQUETTE / NE PAS CETTE ÉTIQUETTE enlever

MODEL / MODÈLE: “P61A”

Room Heater Pellet Fuel-Burning Type

SUITABLE FOR MOBILE-HOME INSTALLATION

This pellet burning appliance has been tested and listed for use in

Manufactured Homes In accordance with OAR 814-23-900 through 814-23-909

Made in U.S.A. of US and imported parts. / Fabriqué

aux États-Unis-d’Amérique par des pièces d’origine

américaine et pièces importées.

BARCODE LABEL

HF

Serial No.

N

o

 de série:

P.N. 3-90-08626_R11

2"(51mm)

12" (305mm) with side shields

18" (457mm) w/out side shields

9”(228mm)

13”(330mm) 

9"(228mm)

13”(330mm)

PROTECTION DE SOL

FLOOR PROTECTION

A

C

B

F

loor

 

protector

Room Heater, Pellet Fuel-Burning Type, Also For Use In Mobile Homes. (UM) 84-HUD

“PREVENT HOUSE FIRES”

 Install and use only in accordance with manufactures 

installation and operation instructions.

This wood heater needs periodic inspection and repair for proper operation. Consult 

the owner’s manual for further information. It is against federal regulations to operate 

this wood heater in a manner inconsistent with the operating instructions in the owner’s 

manual.

Contact local building or fire officials about restrictions and installation inspection in 

your area.

WARNING: FOR MANUFACTURED HOMES:

 Do not install appliance in a sleeping 

room. An outside combustion air inlet must be provided. The structural integrity of the 

manufactured home floor, ceiling and walls must be maintained.

Refer to manufacturer’s instructions and local codes for precautions required for 

passing chimney through a combustible wall or ceiling. Inspect and clean exhaust 

venting system frequently in accordance with manufacturer’s instructions.

Use a 3” or 4” diameter type “L” or “PL” venting system.

Do not connect this unit to a chimney flue servicing another appliance.

Do not obstruct the space beneath the heater.

FOR USE WITH PELLETIZED WOOD FUEL ONLY.

Input Rating Max: 7.1 lb. fuel/hr

EPA Certified Emissions: 1.7 g/hr

U.S. Electrical Rating: 115 VAC, 60 Hz, Start 4.2 AMPS, Run 2.8 AMPS

Fuel Type: Wood Pellet.

Route power cord away from unit.

OPERATE ONLY WITH DOORS CLOSED

DANGER:

 Risk of Electrical Shock. Disconnect Power Before Servicing Unit.

For Further Instruction, Refer To Installation and Owner’s Manual.

Replace glass only with 5mm mirrored ceramic available from your dealer.

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE

MINIMUM CLEARANCES TO COMBUSTIBLES/ DISTANCES DE 

SECURITE PAR RAPPORT AUX MATERIAUX COMBUSTIBLES:

Without

Side Shields
Sans Écrans

Latéraux

With

Side Shields
Avec Écrans

Latéraux

Back Wall / Entre Mur Arrière  2”/ 51mm 

2”/ 51mm

Side Wall / Entre Paroi Latér  18”/ 457mm  12”/ 305mm

CORNER INSTALLATION / EN ANGLE

Walls to Appliance  / 

13”/330mm  9”/228mm

Entre Murs et appareil

FLOOR PROTECTION / Protection Du Plancher

  

USA

 

Canada

Sides/Côtés  (A) 

6” 

152mm

Back/Arrière  (B) 

6” 

152mm

Front/Avant  (C) 

6” 

152mm

Floor Protection Must Be a Non-Combustible Material. Must Also be 

Place Under Any Horizontal Flue Connector, Extending 2” or 51mm 

Beyond the Pipe Measurement.

Pour protéger le plancher, il faut sous le pêole un matériau. Qui doit 

aussi être placé sous les parties horizontales du tuyau de raccord à la 

cheminée et s’étendre à 51mm ø 2 po. au-delà de la mesure du tuyau.

US ENVIRONMENTAL PROTECTION AGENCY

Certified to comply with 2015 particulate emission standards. Not approved for sale after May 15, 2020.

Certifié conforme aux normes 2015 d’émission de particules. Non approuvé pour la vente après le 15 mai 2020.

Date of Manufacture / Date de fabrication:

2018   2019   2020   JAN   FEB   MAR   APR   MAY   JUN   JUL   AUG   SEP   OCT   NOV   DEC

Manufactured by / Fabriqué par: Hearth and Home Technologies 352 Mountain House Road, Halifax PA 17032

LABEL TICKET

ECO:

88378

LABEL SIZE:

4.375” H x 10.75” W

PART # / REV:

3-90-08626_R11

ADHESIVE:

3M 486 Adhesive

ORIGINATOR:

Spidlet

MATERIAL:

24 Gauge Aluminum

DATE:

06/18

INK:

Black Background

Corners .062

Barcode label must have the serial number on it. The 

barcode label must be able to read Code 39 Full ASCII.

352 Mountain House Road

Halifax, PA 17032

Serial Number

Model Name

EXAMPLE

Summary of Contents for P43

Page 1: ...s Keep children away CAREFULLY SUPERVISE children in same room as stove Alertchildrenandadultstohazardsofhightemperatures High temperatures may ignite clothing or other flammable materials Keep clothi...

Page 2: ...et le manuel du propri taire Remplacer le verre seulement avec 5mm miroir en c ramique disponibles chez votre revendeur Ne ENLEVEZ PAS CETTE TIQUETTE NE PAS CETTE TIQUETTE enlever MODEL MOD LE P61A Ro...

Page 3: ...anual Ignition 24 E Service Parts 25 P43 25 P61A 29 P68 34 F Limited Lifetime Warranty 40 G Contact Information 44 Contains updated information 1 Welcome A Congratulations 2 2 Product Specific and Imp...

Page 4: ...Use STANDARD s ASTM E 1509 04 ULC ORD C1482 M1990 ULC S627 00 EPA Method 28 5G MODEL P61A Pellet Stove LABORATORY OMNI Test Laboratories Inc REPORT NO 135 S 22 4 135 S 22b 6 2 TYPE Pellet Fueled Suppl...

Page 5: ...ency using data collected during EPA emissions test Weighted average HHV efficiency using data collected during EPA emissions test A range of BTU outputs based on EPA Default Efficiency and the burn r...

Page 6: ...Safety 3 General Information B Clear Space WARNING RISK OF FIRE Do NOT place combustible objects in front or to the sides of the appliance High temperatures may ignite clothing furniture or draperies...

Page 7: ...r scale marked from 1 to 7 Mode Selector Allows you to choose between Room Temp Mode Constant burn Mode or OFF Also allows you to vary the distribution blower speed by turning the knob to the high or...

Page 8: ...od by products Source material typically determines ash content Higher Ash Content Material Hardwoods with high mineral content Bark and leaves as source material Standard grade pellets Lower Ash Cont...

Page 9: ...ally set If the appliance is set at one of the lower settings it will run quieter but take longer to heat up an area than if it were set at a higher burn rate Regardless of the burn rate when the area...

Page 10: ...stics test to insure the control is operating properly This is normal 3 For your first fire it may be necessary to purge the auger system by putting the feed limit knob to Test prior to starting the u...

Page 11: ...emp mode however the blower will turn on and off in accordance to what temperature the room sensor is reading When the room sensor is satisfied the blower will shut down until the room sensor sees a d...

Page 12: ...r element to operate if the view door is open 4 Adjust Feed Limit If this is your first fire or you are trying different pellets set the feed limit to 4 Figure 4 6 This is a conservative number and wi...

Page 13: ...tant fuel consumption rate is sacrificed for exact room temperature Therefore as it gets colder more pellets will be burned automatically The distribution blower speed will vary according to the posit...

Page 14: ...ce before servicing Smoke spillage into room can occur if appliance is not cool before unplugging Risk of shock if appliance not unplugged before servicing appliance CAUTION When properly maintained y...

Page 15: ...ashes into a steel non combustible container with tight fitting lid outside Use provided paint brush Vacuum loose ash from around igniter and inside burn pot Stove MUST be turned off cold and unplugge...

Page 16: ...e self adhesive 1 4 gasket material around the front face of the glass Set the glass panel and gasket gently onto the door Install the hold down clips and tighten with bolts Glass Cleaning Sometimes i...

Page 17: ...e burn pot This will help knock pieces of ash loosened by the scraping process down through the holes It also helps knock scale off of the igniter element Figure 5 3 The igniter is made to be removabl...

Page 18: ...ke cover pull towards the front of the unit while sliding to the right Figure 5 6 Now that the combustion intake cover is removed you can remove any flyash or debris that has collected around combusti...

Page 19: ...16 wing nut Figure 5 8 Lift up and slide the cover off of the threaded stud Inspect and clean the inner chamber if necessary Figure 5 9 Reinstall the cover making certain it is seated properly on the...

Page 20: ...et disconnect power cord for a few seconds and reconnect If error still occurs call your Dealer A Error Code Description B Frequently Asked Questions ISSUES SOLUTIONS 1 Metallic noise 1 Noise is cause...

Page 21: ...osis of a problem and the corrective action to be taken This troubleshooting guide can only be used by a qualified service technician STOVE DOES NOT FEED 1 No fuel in hopper 2 Firebox draft may be too...

Page 22: ...iner until all cinders have thoroughly cooled Soot and fly ash Formation and need for removal The products of combustion contain small particles of fly ash The fly ash will collect in the exhaust vent...

Page 23: ...ty control There are 2 high limits one normal operation high limit and one backup high limit The control has an automatic diagnostic circuit that continuously monitors the ESP and Room Sensor for faul...

Page 24: ...emain shut down If the fire is out and the ESP is still warm the feeder may restart Since the fire is out the ESP temperature will not rise The unit will then shut down and may flash a six blink statu...

Page 25: ...1 10 04300 Y Hopper Knob Post 008168147 1 00 02000 1 Hopper Latch Assembly Post 008168147 1 00 773901 Hopper Lid w Hinge Swell Latch Pre 008168147 1 10 08518 Hopper Lid w Hinge Knob Post 008168147 1...

Page 26: ...Gasket Ultra Air Intake Pkg of 10 3 44 677160 10 Y 2 8 Ultra Feeder Weldment 1 10 724132 Y 2 9 UL Feeder Pusher Arm 1 10 677187W Y 2 10 Fines De ector No longer available 2 00 677138 10 2 11 Gasket U...

Page 27: ...7738106A Post 008168147 1 10 773904A Wood Handle Pre HF183104 3 40 08746 3 Post HF183104 1600663 Y 17 Bolt on Hinge 2 00 06968B 18 Cast Door Frame 4 00 06800P Cast Door w Glass 1 10 06800A 19 Glass P...

Page 28: ...et Hopper Throat 3 44 677185 Y Gasket Burn Pot 3 44 237639 Y Glass Clip Pkg of 4 1 00 249140 Y Hopper Muf er and Fitting 1 set 1 00 18186618 Y Igniter 3 20 677200 Y Pkg of 10 1 00 677200 Y Label Cauti...

Page 29: ...n COMMENTS PART NUMBER 1 Hopper Assembly Pre 008085092 1 10 08622 Y Post 008085092 1 10 05803 Hopper Extension Switch Kit 1 00 06826 Y Hopper Knob Post 008093438 1 00 02000 1 Hopper Latch Assembly Pos...

Page 30: ...61 2 3 Feeder Weldment Must Also Order 1 00 677122 1 10 677150 Y 2 4 Slide Plate Assembly 1 10 08037 Y 2 5 Pusher Arm Assembly 1 10 06691 Y 2 6 Feed Cover and Gasket 2 00 247217B 2 7 Auger Assembly 3...

Page 31: ...r Air Intake Pkg of 6 3 44 72224 6 Y 3 6 UL Feeder Air Intake 1 10 72228 3 7 Gasket Ultra Air Intake Pkg of 10 3 44 677160 10 Y 3 8 Ultra Feeder Weldment 1 10 724132 Y 3 9 UL Feeder Pusher Arm 1 10 67...

Page 32: ...Y 13 Rear Cover Right 2 00 06468 2P Y 14 Comb Intake Weldment 1 10 08516S Y 15 Retainer Assembly 1 10 08533S Y 16 Ash Pan 1 10 05800 Y 17 Ash Door Assembly Pre 008093438 1 10 06724S Post 008093438 1 1...

Page 33: ...Tailpipe Pkg of 5 1 00 07381 Y Gasket Hopper Lid 1 00 00248 Y Hopper Lid W Hinge Swell Latch Pre 008093438 1 10 09109 Y Hopper Lid w Hinge Knob Post 008093438 1 10 06493 Igniter 3 20 677200 Y Pkg of 1...

Page 34: ...688 12 Forest Green Jan 2010 Retired Units IMPORTANT THIS IS DATED INFORMATION Parts must be ordered from a dealer or distributor Hearth and Home Technologies does not sell directly to consumers Provi...

Page 35: ...1 2 3 Feeder Weldment Must Also Order 1 00 677122 1 10 677150 Y 2 4 Slide Plate Assembly 1 10 08037 Y 2 5 Pusher Arm Assembly 1 10 06719 Y 2 6 Feed Cover and Gasket 2 00 247217B 2 7 Auger Assembly 3 5...

Page 36: ...embly 1 10 06810A 3 5 Gasket Feeder Air Intake Pkg of 6 3 44 72224 6 Y 3 6 UL Feeder Air Intake 1 10 72228 3 7 Gasket Ultra Air Intake Pkg of 10 3 44 677160 10 Y 3 8 Ultra Feeder Weldment 1 10 724132...

Page 37: ...r Left 2 00 06468 1P Y 13 Rear Cover Right 2 00 06468 2P Y 14 Door Latch Assembly 1 00 06713 Y Contains Latch Adjustment SHCS 1 4 20 X 1 Lock Nut 1 4 X 20 Jam Nut HX Jam 1 4 20Z Steel Bushing 15 Comb...

Page 38: ...0637 Y Draft Meter Bolt and Tube 1 00 04004 Fuse 5 Amp Pkg of 5 3 20 23705 5 Y Gasket 1 4 Rope Black W PSA Glass 15 Ft 1 00 2312 Y Gasket 3 8 Rope White LD Ash or Load Door 30 Ft 1 00 00888 Y Gasket B...

Page 39: ...and serial number when requesting service parts from your dealer or distributor Stocked at Depot ITEM Description COMMENTS PART NUMBER Leaf Door Trim Gold 3 43 06717 4 Brushed Stainless 3 43 06717 7 B...

Page 40: ...ing or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier However the warranty shall commence no later than 24 months following the d...

Page 41: ...e changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enameled surfaces caused by fingerprints acciden...

Page 42: ...t limited to improper chimney or venting installation LIMITATIONS OF LIABILITY The owner s exclusive remedy and HHT s sole obligation under this warranty under any other warranty express or implied or...

Page 43: ...Harman P Series Owner s Manual_R23 2014 ___ 02 19 43 3 90 436168c...

Page 44: ...___________________________________________________________________________ ________________________________________________________________________________ ___________________________________________...

Reviews: