29
3-90-07205R26_10/14
Automatic Ignition
(Cont.)
8.
Turn the MIN. TeMP. dial
on the control board to the
desired Minimum temperature. This will start the lighting
process if the temperature at the aquastat sensor is
approximately 5° F. less than the set temperature on the
MAX. TEMP. dial.
This is more than just an automatic ignition pellet boiler.
The automatic system will allow the fire size to be adjusted
to match the heating needs and even put the fire out if
necessary. If heat is needed after the fire is out, the boiler
will automatically re-ignite and adjust the fire size to match
the heating need.
9.
Fill hopper
with pellets and
remove ashes
as required.
Type of Fuel
Use pelletized wood only. The lower the ash content of the
pellets the less cleaning that will be needed of the heat
exchanger surfaces. The cleaner these surfaces are kept,
the more efficient the boiler will be.
Store pellets in the manufacturer’s wrapping until needed
to prevent pellets from absorbing moisture. do not store
fuel within the appliance installation clearances, or within
the space required for fueling, ash removal, and other
routine maintenance operations.
Fire Hazard.
Keep combustible materials, gasoline
and other flammable vapors and liquids
clear of appliance.
WARNING
!
• Do NOT store flammable materials in the appliance’s vicinity.
• NEVER USE GASOLINE, GASOLINE-TYPE LANTERN
FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR
SIMILAR LIQUIDS TO START OR “FRESHEN UP” A FIRE
IN THIS HEATER. KEEP ALL SUCH LIQUIDS WELL AWAY
FROM THE HEATER WHILE IT IS IN USE.
• DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS
SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL.
• DO NOT USE CHEMICALS OF FLUIDS TO START THE
FIRE.
• Combustible materials may ignite.
Summary of Contents for PB 105