1.
If starting after an empty hopper, turn Feed Adjuster
to “TEST”
(for one 60 second cycle). This will charge pellets
into the auger tube and also allow you to check the motors
for operation. Figure 4.5.
NOTE: The auger motor will not operate with the furnace
door open.
2.
Turn Feed Adjuster to #4.
If this is your first fire, or you are trying different pellets, set
the feed adjuster to #4, Figure 4.6. This is a conservative
number and will probably need to be increased if maximum
BTU output is desired. After you know a feed rate setting that
works well for your application, use that setting.
3.
Flip the Igniter Switch up
into the “AUTO-LIGHT”
position, Figure 4.7.
Figure 4.5
Figure 4.6
Figure 4.7
E. Automatic Ignition
Fire Risk
Do NOT operate appliance:
• With fuel-loading or ash-removal doors
open.
• Burnpot floor open.
• Cleaning slide plates open.
Do NOT store fuel:
• Closer than required clearances to
combustibles to appliance
• Within space required for loading or ash
removal.
WARNING
!
WARNING
!
HOT wHILE IN OPERATION. KEEP CHILDREN,
CLOTHING, AND FURNITURE AwAY. CONTACT MAY
CAUSE SKIN BURNS.