ASSEmblY

Firebrick Diagram

blower

 

The blower slides into the channel bracket on the rear 

of the stove as shown at right. Plug the blower into a 

properly grounded receptacle.

Shaker handle

The shaker handle installs onto the shaker handle 

mount using the two hex-bolts and washers provided. 

Firebricks

The SF250 uses 14 “standard” firebricks, as shown 

below. These standard firebricks measure 9” X 4½” 

X 1¼” each. The firebricks are already installed in 

the stove but can be removed to lighten the stove for 

moving. The doors can also be removed by simply lift-

ing them off of the hinges. 

Summary of Contents for SF 250

Page 1: ...MAY RESULT FOR YOUR SAFETY FOL LOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA Contact your local authorit...

Page 2: ...Table of Contents Safety Considerations 3 Assembly 4 Installation 5 Chimney Venting 6 Operating Instructions 8 Preventive Maintenance 9 Optional Hot Water Coil 10 Testing Label 12 Warranty 13...

Page 3: ...rate It has been verified that creosote will ignite at 650 degrees fahrenheit It is the owner s responsibility to follow these recommenda tions This stove consumes air when it is burning if your house...

Page 4: ...The shaker handle installs onto the shaker handle mount using the two hex bolts and washers provided Firebricks The SF250 uses 14 standard firebricks as shown below These standard firebricks measure 9...

Page 5: ...hould con sist of 3 8 millboard or a stove board providing equal protection k 84 R 45 The floor protection should extend 8 to the rear and either side and 16 in front of the stove The floor protection...

Page 6: ...from the stove collar The chimney must be two feet higher than anything within ten feet It also must extend three feet above the point where it intersects or exits the roof line In order to have a pro...

Page 7: ...uld be no more than two 90 elbows or the equivalent used in connecting the stove to the chimney flue H Shared Flue No more than one appliance shall vent into a single flue The most common cause of poo...

Page 8: ...in between Loading Coal should only be added when there is a reasonably hot fire The coal bed should be bright and vigorous If the fire is burning hot and there is a deep bed of coals full loads can...

Page 9: ...After cleaning the chimney any debris will be at the bottom by the clean out door Open the clean out and vacuum the loose debris Clean the smoke pipe from the chimney to the stove using a metal brush...

Page 10: ...supplied nuts on each leg of the coil Place the coil through the holes in the stove and adjust the nuts so that the pipes stick out about 1 to 1 from the sidewall of the stove Put flat wash ers and nu...

Page 11: ...2 Circulating pump method Used when the distance is more than ten feet or when the stove is on a higher level than the existing water heater In addition to a circulator you may want to add a aquastat...

Page 12: ...testing label 12 This appliance is also approved for installation into a shop...