Pinnacle 101 Stair Lift
INSTALLATION PROCEDURES
Figure 12-1
1.
If the LED indicator light is not green, check the
safety senors:
•
Seat swivel sensor (seat should be in the
locked position)
•
Footrest lower sensor (check by pushing in
on the safety pan on the footrest)
•
Upper foot pan safety sensor (check by
pushing on the safety pan on the footrest).
•
Front foot pan safety sensor (check by
pushing on the safety pan on the footrest).
•
Uphill safety sensor (ensure nothing is
blocking upward passage)
•
Downhill safety sensor (ensure nothing is
blocking downward passage)
If the LED indicator light is still not green after
testing sensors, turn the unit off and re-check all
wire plugs. Turn the unit on again and re-check the
LED indicator light cycle. When the LED indicator
light remains green the lift is ready to operate.
[Figure 12-1]
F. LED & AUDIBLE TONES
2. TONES INFORMATION
Minor faults
Single long beep (will reset once fault is cleared)
•
Seat swiveled out of position
•
Edge safety detected
•
Under foot rest
•
Current overload condition
•
A Low battery voltage condition
Pulsing Beep
Lift stopped off of charge strip. Will sound after 30
second for 30 seconds. It will repeat ever 10 minutes
until lift is operated or returned to charge strips.
Tones
Beeps
Runaway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
No Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Conflicting Switches Footrest UP & Footrest DOWN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Conflicting Switches Obstruction UP & Obstruction Down . . . . . . . . . . . . . . . . . . . . . . . . .4
Conflicting Switches Footrest DOWN & Obstruction UP . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Conflicting Switches Footrest UP & Obstruction DOWN . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Conflicting Switches STOP UP & STOP DOWN switches both Detected . . . . . . . . . . . . .7
Conflicting Switches STOP UP & STOP DOWN switches both not Detected . . . . . . . . .8
Helix Only LIMIT Switch Dectected . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Major Fault Codes