17
Do Not Burn Wet Coal!
Super-Magnum Coal Stoker Stove
3-90-02702R6_03/13
B. Leveling the Appliance
To adjust the leveling bolts, you must first loosen the locking
nut. Turn the leveling bolt to the desired position, and re
tighten the locking nut against the cast iron leg.
C. Optional Heat Transfer Kit
The duct piping must be of metal construction in
accordance with NFPA 90B, 2-1.1, and 2-1.3.
1.
Lift and remove the round cover from the top of the
Super Magnum.
2.
Install the 6" duct pipe starting collar into the round
opening. Reaching down through the starting collar,
bend the tabs upward to secure the collar to the stove.
3. Attach your 6" duct, coming from a heat register located
a
minimum of 17 ft.
away, to the starting collar. Secure
the duct to the starting collar with a minimum of three
screws.
4. Maintain a minimum of 1" clearance to combustible
materials with the entire length of duct.
5. If maximum heat transfer to the duct is desired, replace
the air grill, from the front of the stove, with the cover
plate from the kit. (See Page 18)
FOR YOUR SAFETY
- At 17 to 21 feet of duct length, the 1/2
inch tab
MUST
be removed from the top of the plate. At 21
feet or more, the cover plate can remain solid, allowing all
of the heated air to flow through the duct pipe.
D. Air Filter
To ensure cleanliness of the air circulated through the
heat exchange, the Super Magnum is equipped with a
replaceable filter. The filter is located under the stove. To
remove the filter, loosen the two thumb screws and remove
the cover. Slide the filter out the open slots in the front of
the channel.
Check the filter for damage, change if necessary.
Replacement filters can be obtained through your Harman
dealer, or from most hardware, or building supply centers.
Be sure to turn the blower off prior to changing
E. Optional Decorative Tile Kit
To install the optional ash door tile, you'll first need to
unassemble the ash door.
1. Lay the ash door, face down, on a flat workspace.
2.
Remove the four screws which hold the filler plate into
the door.
3. Lay the filler plate and screws aside, and lay the tile into
place on the door assuring that the tile is centered on
the gasket.
4. Apply the self adhesive gasket onto the back side of the
tile.
5. With the filler plate flipped over from its original position,
it now becomes the backer for the tile. Attach using the
four screws.
Break-away tab for duct
lengths between 17 &21 feet.
Do not connect this appliance to the supply duct of an
existing furnace. This option is intended for use with a
single heat register.
Thumb Screws
Filter Cover
Filter
3-43-02730 ASH DOOR TILE
3-30-3110240382
BHSCS 10-24 X 3/8"
AD FILLER PLATE
3-44-11862 3/8" GASKET W/PSA
ASH DOOR