TLC 2000 Parts List

1. 

-00-85109L 

 

TLC Rear Top

-00-8519 

 

TLC Rear Hinge ( per unit)

3. 

1-10-0870A 

 

TLC Front Top

4.  

1-00-08710   

 

TLC-000 Top Air Grill Assembly (Option)

5.  

3-44-10050   

 

1 1/" Tadpole gasket (39")

6. 

-00-85149L 

 

TLC Gasket Plate

7.  

-00-85153 

 

TLC Cleanout

8A.  -00-85140-B   

TLC Airwash Adjuster - Right

8B. 

-00-85140-1B   

TLC Airwash Adjuster - Left

9.  

-00-85141P 

 

TLC Right Side Shield

10A.  -00-85145 

 

TLC Coal Bar (3 per unit)

10B.  -00-85144 

 

TLC Coal Bar Holder ( per unit)

11A.   1-10-08159A 

 

TL Cast Load Door - Roped

11B.  1-10-05165   

 

TL Gold Load Door - Roped

1.   3-43-47386 

 

TL Brass Ash Lip Trim

13.   1-10-08690   

 

TLC Ash Pan Assembly

14.   1-10-08718A 

 

TLC Ash Door Assembly- 

Includes all **

15. 

-00-8513** 

 

TLC Bottom Slide Rail

16A.   -00-85135** 

 

TLC Airslide

16B.  3-31-08739** 

 

5/16 - 18 x  1/ All Thread

17.   -00-85133** 

 

TLC Top Slide Tail

18.   -00-854148** 

 

TLC Airslide Cover

19. 

3-40-08746   

 

TLC Airslide Knob

20.  2-00-852136**   

TLC Ash Door Latch

1. 

-00-0874   

 

TLC Front Brick Support 

 

-00-0875   

 

TLC Rear Brick Support

-00-0876   

 

TLC Side Brick Support ( per unit)

3. 

3-40-90045015   

9 x 4 1/ x 1 1/4 Firebrick (11 per unit)

4. 

-00-85119  

 

TLC Grate Link

5.   3-00-0008   

 

Long Grate ( per unit)

6. 

1-00-08643   

 

TLC-000 Blower Option

7. 

1-10-85166 

 

TLC Shaker Handle Weldment

8. 

-00-85139P 

 

TLC Left Side Shield

9. 

1-10-85138W 

 

TLC Air Jacket Weldment

30. 

-00-85160B 

 

TLC Heat Shield

31. 

3-40-058   

 

TL Wooden Knob

32.  1-10-08722   

 

TLC Damper Linkage Arm Weldment

33. 

-00-8518P 

 

TLC Top Lift Arm With Notch

34. 

-00-85147 

 

TLC Brick Backer ( per unit) 

not indicated

35.  3-31-08724   

 

1/4 & 3/8 Dowel Pin (2 per unit) 

not pictured

Summary of Contents for TLC 2000

Page 1: ...OLLOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA Contact your local authority such as municipal building...

Page 2: ...E THESE INSTRUCTIONS Harman Home Heating 352 Mountain House Road Halifax PA 17032 U S A INDEX Specifications 4 Operation 6 Building a Fire 7 Maintenance 11 Installation 13 Chimney System 15 Parts List...

Page 3: ...ly heavier or lighter than air Therefore it is best to install the detector at table top level rather than on the ceiling like a smoke de tector CO detectors are very sensitive and may sound an alarm...

Page 4: ...ications Harman TLC 2000 Weight 375 lbs Flue Size 6 inch Fuel Pea Nut or Stove coal Cordwood with optionalspark screen Log Length Recommended 16 with 18 Max Heating Capacity 1 900 sq ft Blower Size op...

Page 5: ...Coal Stove Top Load Door Top Load Door Arm Side Shield Ash Door Latch Ash Door Coal Air Control Front Load Door Latch Top Load Opening Glass Door Grates Wood Air Control Removable Shaker Handle Clean...

Page 6: ...the glass is broken or damaged do not operate the stove until it has been replaced Grates The TLC 2000 s unique grate system consists of two Cast iron grates linked together to operate simaltainiousl...

Page 7: ...nded that the coal control be positioned to the left for wood burning WOOD COAL WOOD Building and Maintaining a Wood Fire Neveruse gasoline gasoline type lantern fuel kerosene charcoal lighterfluid or...

Page 8: ...es from the fire chamber periodically by shaking the grates Wood burns best with an ash bed under the wood therefore do not shake all of the ashes down Never let the ashes build up to over 3 in depth...

Page 9: ...mell this is just the paint going through the curing process and will disappear after a few fires Overfiring Avoid overfiring your stove a potentially hazardous situ ation which can lead to overheatin...

Page 10: ...imum postion by sliding it to the right Allow the fire to burn vigorously for several minutes Shake the grates with short choppy strokes until the first red coals fall into the ash pan then stop Add c...

Page 11: ...er or any prolonged period when you are not using your stove The Fire Chamber The inside of the fire chamber should be examined for damage to the firebrick lining material and grates If any bricks hav...

Page 12: ...ss while it is hot and do not use abra sive substances Wash the surface with cool water and rinse thoroughly You may wish to use a non abrasive cleaner specifically designed for use on stove glass In...

Page 13: ...a grounded outlet and may not be routed above under over or around the stove itself Blower Variable Speed knob Top Air Grill Optional The top air grill must be installed before the chimney con nector...

Page 14: ...ance distances other than those pre sented here Parallel versus Corner Installations A parallel installation is one in which the back and sides of the stove are parallel to the walls behind and to the...

Page 15: ...your stove Signs of an overdraft include rapid fuel consumption inability to slow the fire and parts of the stove or chimney connector glowing red It is important that you follow the chimney guideline...

Page 16: ...m recommended height for any chimney is 16 ft 4 8 m above flue collar height A round flue either masonry or approved prefabricated of either 6 150 mm 7 180 mm or 8 200 mm may be used For square or rec...

Page 17: ...e Be sure to contact your building code inspection official to see if this option is allowed in your area and to find out the specific requirements for such an installation Existing Masonry Chimneys I...

Page 18: ...fuels such as charcoal can cause increased carbon mon oxide production or overfiring Never use highly volatile substances in your stove such as gasoline which could cause an explosion When solid fuel...

Page 19: ...2 00 852132 TLC Bottom Slide Rail 16A 2 00 852135 TLC Airslide 16B 3 31 08739 5 16 18 x 2 1 2 All Thread 17 2 00 852133 TLC Top Slide Tail 18 2 00 854148 TLC Airslide Cover 19 3 40 08746 TLC Airslide...

Page 20: ...TLC 2000 Coal Stove 20 26 28 1 22 21 29 9 14 18 12 13 10B 27 3 2 2 4 5 6 32 31 7 8A 11A 23 17 16A 20 15 19 25 24 30 8B 33 10A 11B 16B...

Page 21: ......

Page 22: ......

Page 23: ...Notes...

Page 24: ...TLC 2000 Owner s Manual 3 90 08691 Rev 9...

Reviews: