HELIX:
Install Manual
24SEP2021 | 630-00063-01 REV D
15
INSTALLATION
HELIX CURVED STAIR LIFT: SECTION 3
FINAL LIMIT
1.
Install hard final limit on the gear rack at both
ends of the rail. Rail end caps and support caps
need to be installed. See Figure 3-40.
Figure 3-40
OVERSPEED
This is an emergency brake that is designed to stop
the lift if it has a runaway situation.
1.
Remove tag and screw. See Figure 3-41 and 3-42.
Figure 3-41
Figure 3-42
2.
If the unit fires due to a runaway situation contact
Harmar tech services to evaluate. The unit should
not be put back in service until the reason for
overspeed activation has been determined.
WARNING
!
To activate the overspeed, if you move the arm
it will release a jammer that will go between the
gear rack and the sprocket, and the limit switch
will remove power. See Figure 3-43.
Arm to
release
jammer
Figure 3-43
3.
Resetting the unit, if it is activated as a test or a
false activation it can be reset by pushing it back
in place and resetting the release.
See Figures 3-44 and 3-45 .
Figure 3-44
Figure 3-45
Screw