SL300 PINNACLE STAIR LIFT:
Owners Manual
19JUNE2020 | 610-00058 REV F
12
TROUBLESHOOTING
PINNACLE STAIR LIFT: SECTION 5
MAJOR FAULTS
SECTION 5
TROUBLESHOOTING
•
If the lift does not operate, diagnose the
problem by listening to the beeps emitted.
•
An intermittent beep for 30-seconds indicates
that the lift has been stopped off the charge
station. This repeats every 5 minutes until
the lift is returned to the charge station. It is
recommended that the lift be immediately
moved to a charge strip station located at
either end of the rail.
•
If the beep codes are not able to be cleared
and the lift is not working, please contact your
local dealer.
•
If no light shows on the charger, a problem with
the AC power adapter may be present. Please
contact your dealer.
Number of Beeps
Runaway
1
No Power
2
*Conflicting switches FOOTREST UP and FOOTREST DOWN
3
*Conflicting switches OBSTRUCTION UP and OBSTRUCTION DOWN
4
*Conflicting switches FOOTREST DOWN and OBSTRUCTION UP
5
*Conflicting switches FOOTREST UP and OBSTRUCTION DOWN
6
Conflicting switches STOP UP and STOP DOWN switches both detected
7
Conflicting switches STOP UP and STOP DOWN switches both NOT detected
8
* If configured for your model.