Chapter 6
Operations of display panel
HA-675_V3_02
- 109 -
6-7-2
Functions of test mode
JOG operation
●
Function
Pressing [UP] or [DOWN] key rotates the motor with the
speed of [test mode]
→
[SP:JOG speed].
●
Details
of
display
1st and 2nd digit: [Jo: JOG operation]
3rd to 6th digit:
No indications
●
Operations
(1) To transfer to in [JOG operation] mode, Press the [ADJ] key at least 0.1 second.
⇒
1st digit [J] flashes and servo turns ON automatically.
⇒
JOG operation is available.
(2) To operate the motor forward, press the [UP] key.
⇒
The motor will rotate when the key is pressed, and will stop when the key is left.
(3) To operate the motor reverse, press the [DOWN] key.
⇒
The motor will rotate when the key is pressed, and will stop when the key is released.
(4) To exit from [JOG operation] mode, press the [SET] key at least 0.1 second.
⇒
Flashing of 1st digit [J] stops, servo turns OFF automatically, and [JOG operation] mode
terminates.
●
Related
functions
[JOG speed]:
[test mode]
→
[SP: JOG speed]
[JOG acceleration]: [test mode]
→
[Ac: JOG acceleration]
D O W N
U P
A D J
S E T
JOG
operation
CW
forward
CCW
reverse
Turns on servo to
operate the motor.
D O W N
U P
A D J
S E T
D O W N
U P
A D J
S E T
Turns servo OFF.
[JOG operation] is
unable.
1st digit
6th digit
1.
During JOG operations, no signals output to speed monitor or current monitor.
2. During JOG operation, position is not controlled because the position mode is
switched to the speed mode. Stopped position may shift by external torque and
force, and during long unconcerned period.
CAUTION
Before JOG operation, make sure
load conditions and motor/ encoder
cable installations are correct.
Activating JOG operation mode turns servo
ON automatically. Improper load and poor
cable installation may result in accidents
that may cause physical injury and fire.
WARNING
Before transferring to the test mode,
make the value in the error counter
[0: zero] inputting ON signal to [CN2
clear: CLEAR].
Transferring to the test mode, the servo
power turns ON automatically. For safety,
input ON signal to [CN2 clear: CLEAR] to
make the value in the error counter [0: zero]
before transferring to the test mode from
monitor mode.
CAUTION