Chapter 3 I/O ports
HA-675_V3_02
- 43 -
<< for absolute system >> ABS
◆
The figure below shows a connection example for the absolute system.
CN1
TB1
TB2
HA-675-*A-***
CN2
CN2
2.2k
16
15
2.2k
18
17
2.2k
20
19
2.2k
22
21
DC24V
0V
Ext. power
DC24V
0V
Ext. power
DC24V
0V
Ext. power
DC24V
0V
Ext. power
ESTOP+
ESTOP-
FSTOP+
FSTOP-
RSTOP-
RSTOP+
ORG+
ORG-
33
34
35
43
36
37
38
39
40
41
42
READY
FINISH
ORG-END
ALARM
OUT-DATA1
OUT-DATA2
OUT-DATA4
OUT-DATA8
OUT-DATA16
OUT-DATA32
OUT-COM
Shield
゙
44
45
46
47
48
49
Encoder phase A+ signal
Encoder phase A- signal
Encoder phase B+ signal
Encoder phase B- signal
Encoder phase Z+ signal
Encoder phase Z- signal
25
50
26LS31
L/F
Transformer
Power
AC200V
(50/60Hz)
r
s
R
S
T
Line filter
L/F
NFB
CP
Shield
CLR 6
+5V 1
0V 8
BAT- 4
SD 5
White
Black
Yellow
Blue
E
Green
Red
Orange
Gray
Connector cell
Use shield pair cable
Clamp the end of shield
surely to the cable-clamp of
the connector
Absolute encoder
AC Servo actuator
FHA-**C
M
R1
R2
U
V
W
Red
White
Black
Green/
Yellow
Ground always.
Shield
INPUT-COM
CLEAR
S-ON
ST-ORG
INTERLOCK
1/8
Clear
Servo-ON
Originating
Interlock
DC24V
0V
Ext. power
2.2k
2
2.2k
3
2.2k
4
2.2k
14
2.2k
5
2.2k
6
2.2k
7
2.2k
9
2.2k
10
2.2k
11
2.2k
12
2.2k
13
STOP
INPUT
DATA1
INPUT
DATA2
INPUT
DATA4
INPUT
DATA8
INPUT
DATA16
START
INPUT
DATA32
Start
Stop
Input bit 1
Input bit 2
Input bit 4
Input bit 8
Input bit 16
Input bit 32
2.2k
26
2.2k
+24V
76
130
27
28
ASB-REQ
ABS
Position data
request
76
130
29
30
ASB-CLEAR
SD 7
BAT+ 2
ABS
Ready
Motion finish
At-origin
Alarm
Output bit 1
Output bit 2
Output bit 4
Output bit 8
Output bit 16
Output bit 32
Output common
Line filter
Emer. stop
FWD limit
REW limit
Origin
Monitor ground