15
V01 05/2016 1003370
No.
Designation
Function
Page
D1, D2
7-Segmentanzeige
Device status display
see p. 42
T1, T2
Pushbuttons
Service functions
see p. 42
X1
Power connection
Motor, braking resistor and connection for measurement of DC
link voltage
see p. 27
X2
Connection of control supply U
V
+24 V DC supply voltage for control electronics of drive
controller
see p. 15
X3
AC mains connection
Mains supply
see p. 15
X4
Control terminals
Digital inputs/outputs, analog inputs, STO request incl.
feedback
see p. 24
X5
Motor temperature monitor connection
PTC, based on DIN 44082, Klixon automatic cutout
see p. 31
X6
Resolver connection
Resolver, incl. motor temperature monitor
see p. 29
X7
High-resolution encoder interface
Sin/Cos encoder, TTL encoder, EnDat 2.1 encoder,
HIPERFACE® encoder, SSI encoder, incl. motor temperature
monitor
see p. 30
Option 1
Communication
Factory installed module for field buses, e.g. SERCOS, EtherCAT
see p. 27
Protective conductor connection
Connection diagram see section 3.5
see p. 16
X8 Option 2
Technology
Factory installed module e.g for TTL encoder simulation,
second SIN/COS encoder or EnDat 2.1
see p. 27
X9
Ethernet interface
Service port, connection to PC
see p. 27
X13
Connection of motor brake
Power output with cable break detector
see p. 31
Table 15.1 Key to Connection diagram
Note:
The temperature sensor of the motor winding can be optionally connected via the encoder cables (X6 or X7) or to
terminal X5.