© 2013 Harmonic Inc.
332
Ellipse 3000 r.3.0, Rev. B
Appendix B
Software Upgrade Using FTP
This appendix details the preparations and procedures required for software installation.
Ellipse encoders employ the Fail Safe Upgrade feature. If the device fails to boot three times
after a software upgrade then it reverses the software upgrade and boots with the prior
version.
NOTE:
Viewing the Ellipse software version is available through the front panel:
Root > Configuration > Unit > System > Version Information (see
10.3.2 Version Information Menu
page 269) or the Web Manager (select the Unit > System tabs).
B.1 Ellipse Setup IP
NOTE:
Configure the Ellipse IP Management Port according to local network specifications.
To configure the encoder IP Management on the front panel:
1. Navigate
Root > Configuration > Unit > System > Ethernet Port (Management).
2. Set the following IP Management parameters:
❑
IP Address
❑
Subnet Mask
❑
Default Gateway
Ethernet Port (Management)
1 IP Address
245.123.446.001
2 Subnet Mask
255.255.254.001
3 Default Gateway
245.123.446.002