Omneon, Now Part of Harmonic
13
Replacing a Disk Drive
If you do not have another drive available, contact Omneon
An automatic rebuild will commence on this drive. Continue to
. If an automatic rebuild does not commence on this drive,
contact Omneon
11. On the
RAID Utilities
page, monitor the status for the RAID set.
The status should change from
Compromised
to
Rebuilding
immediately. If it does not, start the rebuild manually by clicking on
Start Rebuild
.
12. Periodically monitor the rebuild until complete. Once complete,
RAID set status will change to
Normal
,
Attached
,
Viable
.
This completes the procedure.
NOTE:
If you replaced a failed drive with a new drive from Omneon, use
the packaging materials (carton, cushion, and electrostatic sensitive bag)
from the replacement disk drive to carefully repackage the failed drive
and return it promptly to Omneon for analysis. Contact Omneon
Technical Support for a Return Authorization Number (RA) before
shipping the drive back to Omneon. Refer to
for
contact information and a shipping address.