Chapter 1: ProStream X hardware specifications and reference topics
ProStream X specifications
A summary of ProStream X technical characteristics.
Table 1-1: General specifications
Parameter
ProStream X
Chassis Dimensions
Width without rails: 439 mm (17.25”)
Width including rails: 450 mm (17.72")
Height: 43.2 mm (1.7”)
Depth: 712 mm (28")
Weight
14.97 kg (33 lb)
AC power supplies
Redundant 1+1 power supply configurations have support for hot
swapping.
AC Input Voltage Range: 90–264 Vrms
Frequency Range: 47–63 Hz
Efficiency: 80 Plus Platinum certified
Thermal: Operating Ambient
Temperature
5 °C to 40 °C
ASHRAE Class A2: 10 °C to 35 °C with the rate of change not to
exceed 10 °C per hour
ASHRAE Class A3 includes operation up to 40 °C for up to 900
hours/year.
ASHRAE Class A4 includes operation up to 45 °C for up to 90
hours/year.
[1]
Thermal: Shipping Ambient
Temperature
-40 °C to 70 °C
Humidity
Shipping: 50% to 90%, non-condensing with a maximum wet
bulb of 28 °C (at temperatures from 25 °C to 35 °C
Altitude
Operating with ASHRAE de-rating: Up to 3050 m
Acoustical Emissions (Sound
Power Measured)
Server rack mounted (BA): 7.0 maximum
[2]
..............................................
1
To maintain ASHRAE compliance, system ambient and altitude combinations must not exceed the Class A3
system ambient and altitude combinations numbers below:
Sea level: 40 °C
900 m: 40 °C
1500 m: 37 °C
3000 m: 28 °C
2
BA is a measurement of sound power corrected (A-weighted) to reflect what a healthy human ear hears. It
can be converted from dBA by applying the equation: LWA (dBA) = 10 * LWA(BA)
8