background image

Spectrum

36

Harmonic corporate contact information

Phone numbers and addresses for the corporate office.

Harmonic corporate address

4300 North First Street

San Jose, CA 95134

U.S.A.

Harmonic corporate telephone numbers

Tel. 1.800.788.1330 (from the U.S. and Canada)

Tel. +1.408.542.2500 (outside the U.S. and Canada)

Fax.+1.408.542.2511

Summary of Contents for Spectrum MediaDeck 7000

Page 1: ...Spectrum MediaDeck 7000 Component Replacement Guide Revision A...

Page 2: ...G Audio technology licensed from Fraunhofer IIS http www iis fraunhofer de amm PitchBlue is a registered trademark of Vigor Systems QuickTime and the QuickTime logo are trademarks or registered tradem...

Page 3: ...ITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT WE DO NOT WARRANT THAT THE SYSTEM WILL MEET YOUR REQUIREMENTS OR BE UNINTERRUPTED OR ERROR FREE NO ADVICE OR INFORMATION WHETHER ORAL OR WRITTEN OBT...

Page 4: ...rceable the remaining parts will be enforced to the maximum extent permitted There are no third party beneficiaries to this Agreement We are not bound by additional and or conflicting provisions in an...

Page 5: ...lling a drive 16 ChannelPort or MediaPort module replacement 18 Deactivating players 18 Detaching an I O module from players 18 Changing the MediaDeck wink state 19 Winking a MediaPort or ChannelPort...

Page 6: ...36 Appendix B Safety and regulatory compliance information 37 Important safety instructions 37 Safety symbols translated safety warning caution instructions English 38 Symboles de s curit et traduits...

Page 7: ...mation to help you replace components in your Spectrum device or system Make sure that you read all safety warnings and instructions and that you have received a replacement component from Harmonic be...

Page 8: ...rum Management ChannelPort or MediaPort module replacement MediaPort or ChannelPort module replacement with Spectrum Management Bezel replacement Over time the bezel LEDs can wear out Replacement beze...

Page 9: ...ul to not over tighten the thumb screws 1 Unpack the bezel 2 Align the bezel in front of the chassis so that the front panel display appears in the top right corner and the metal corners of the bezel...

Page 10: ...you use separate isolated power sources for each AC input Replacing a power supply unit Systems with a single power supply or systems with two power supplies operating in a non redundant configuratio...

Page 11: ...coverage under the Harmonic product limited warranty and maintenance services programs In addition any errors or damages caused by the use of disk drives provided from any other source will cause the...

Page 12: ...Utilities page click Wink On The light bar on the front panel is activated 2 Find the physical location of the drive and note the state of the LEDs for this drive The top Activity LED should be off i...

Page 13: ...match continue with installing the new drive If the serial numbers do not match wait at least 15 seconds after removal then reinsert the drive Call Harmonic Technical Support immediately and do not c...

Page 14: ...Step 3 using the second drive If successful continue to the next step If unsuccessful contact Technical Support for assistance If the drive is not reported as Alive and you do not have another drive...

Page 15: ...ure If you wish to install a Harmonic supplied drive model that is not supported by your current version of Spectrum firmware you may need to install a DDC configuration file to your video server whic...

Page 16: ...Technical Support for assistance and do not continue with this procedure 1 Press the red release button on the right side of the drive to release the handle The handle springs open 2 Grasp the handle...

Page 17: ...ons in Removing a drive to fail the drive remove it and then replace it with another drive if available If successful continue to the next step If you do not have another drive available contact Techn...

Page 18: ...d column The Player Configuration page appears 2 Click the icon for the Spectrum server on which the players reside The Player List page appears 3 Check the box for each Player that you wish to deacti...

Page 19: ...on of the page view the Wink State If currently Off click Wink On If currently On click Wink Off Winking a MediaPort or ChannelPort module In a MediaDeck 7000 identify the physical module by changing...

Page 20: ...olumn check the box for the I O module you wish to remove and then click Remove A confirmation message appears 5 Click OK After a brief pause a message appears indicating that the device has been remo...

Page 21: ...Player page or the Attach Devices page refer to Creating a player in the Harmonic SystemManager User Guide 7 Click Done to return to the Player List page 8 Repeat this procedure for each player that...

Page 22: ...time when replacing a MediaPort or ChannelPort module there is no way to preserve players created with Spectrum Management Any players attached to the original device must be re configured separately...

Page 23: ...k the Wink On button Winking the module When the MediaPort or ChannelPort wink state is on the status LED on the rear panel of the module will be activated 1 Click Monitor Devices MediaDeck 2 Click th...

Page 24: ...cessary cables to the module Refer to the Spectrum Spectrum System Installation Guide for instructions What to do next Use the record of your player and channel settings for the original module to con...

Page 25: ...ed unit if possible This allows the SystemManager to simultaneously display both units and allows you to move Players from the original unit to the new one using the Move Player function IMPORTANT If...

Page 26: ...small amount of disk space You may also stop the File System before performing maintenance on it such as for example such as delete the File System or to removing a RAID set 1 From the Configuration t...

Page 27: ...use to connect to the SystemManager For detailed instructions refer to Connecting your Gigabit Ethernet Network in the Spectrum System Installation Guide 8 Attach any remaining cables to the new Media...

Page 28: ...s displayed the Physical View and Logical View 3 At the top of the Logical View column click the link to the File System name The Filesystem Utilities page displays 4 If you are replacing a Spectrum s...

Page 29: ...dropdown box to select the host of the original Spectrum server which has the players you wish to move 4 Click Select Players The Select Players page appears showing a list of those players that resid...

Page 30: ...mManager User Guide for information on configuring your Harmonic MediaGrid Accounts 3 Configure your Access Control settings Refer to Configuring Access Control settings for video servers in the Harmo...

Page 31: ...they can be moved to the replacement video server Failure to save settings such as Playout Channel configuration playlists and schedules as directed by Technical Support before replacing a Spectrum v...

Page 32: ...sources 4 Remove the bezel from the original MediaDeck For instructions refer to Bezel replacement in this guide 5 Remove the drives from the original MediaDeck and install each drive in the same orde...

Page 33: ...re continue to the next step 5 Check the status of the file system on the new MediaDeck by clicking Configure Storage File System Depending on the version of software the Status field may appear as St...

Page 34: ...Media Fetch Refer to Configuring Media Fetch in the Help system 9 Restart the new MediaDeck by clicking Monitor Devices MeidaDeck Restart The complete restart process takes approximately three minutes...

Page 35: ...rmonicinc com India 91 120 498 3199 apacsupport harmonicinc com Russia 7 495 926 4608 rusupport harmonicinc com China 86 10 6569 5580 chinasupport harmonicinc com Japan 81 3 5565 6737 japansupport har...

Page 36: ...rs and addresses for the corporate office Harmonic corporate address 4300 North First Street San Jose CA 95134 U S A Harmonic corporate telephone numbers Tel 1 800 788 1330 from the U S and Canada Tel...

Page 37: ...nvironmental safety and EMC standards Important safety instructions This section provides important safety guidelines for operators and service personnel Specific warnings and cautions are found throu...

Page 38: ...hen installing or replacing the unit always make the ground connection first and disconnect it last Installation of the unit must comply with local and national electrical codes This unit is intended...

Page 39: ...uctor To avoid electric shock plug the power cord into a properly wired receptacle before connecting the product input or outputs Route power cords and other cables so that they are not likely to be d...

Page 40: ...e a unit with a broken fibre or with a separated fiber connector Warning Lithium battery handling safety instructions CALIFORNIA PERCHLORATE ADVISORY Some lithium batteries may contain perchlorate mat...

Page 41: ...avant d installer des options ou d effectuer l entretien de l unit moins d instructions contraires dans le pr sent manuel Avertissement Rack monture avertissement Pour viter les blessures corporelles...

Page 42: ...pareil Afin d viter les lessures ne pas toucher les connexions et composants expos s lorsque l appareil est sous tension Ne rien ins rer dans l une ou l autre des cavit s des prises de courant du syst...

Page 43: ...nnecteurs d branch s Ne pas regarder en faisceaux ou regarder directement avec des instruments optiques Ne jamais faire fonctionner une unit en cas de bris d une fibre ou de s paration d un connecteur...

Page 44: ...in Bereichen mit beschr nktem Zutritt vorgesehen Ein Bereich mit beschr nktem Zutritt ist ein Bereich zu dem nur Wartungspersonal mit einem Spezialwerkzeugs Schlo und Schl ssel oder anderer Sicherheit...

Page 45: ...e das Chassis nicht an den Henkeln auf den Elementen wie z B Stromanschl sse K hlungen oder Karten heben oder kippen oder indem Sie es unterhalb der Unterkante packen Alle Hinweise in diesem Handbuch...

Page 46: ...liegenden Anschl sse und Komponenten w hrend schaltet ist Sie keine Gegenst nde in einem der beiden Stromversorgungs Hohlr ume des Systems mit Strom verbunden einf hren Ein Wechelstromsmodul und ein G...

Page 47: ...regelm igen Abst nden berpr fen Empfohlener Wert ist zwischen 1 und 10 Mega Ohm MOhm Warnung Laserstrahlungen Warnung Unsichtbare Laserstrahlung kann von getrennten Fasern oder Stecker emittiert werde...

Page 48: ...open rack whenever possible If installation in an enclosed rack is unavoidable ensure that the rack has adequate ventilation Reliable earthing of rack mounted equipment should be maintained Particula...

Page 49: ...h great care Handle fibers only in areas that are very clean and do not contain sharp objects Wear finger cots or gloves as dirt and oils can damage the fiber and contaminate connectors Do not allow k...

Page 50: ...using the proper tools required for disassembling equipment Untrained personnel shall not disassemble Harmonic products Unfamiliarity with tools can cause damage and injury R gles de s curit Le person...

Page 51: ...nic equipment and other equipment must be made in a manner that is consistent with maintaining compliance with FCC radio frequency emission limits Modifications to this equipment not expressly approve...

Page 52: ...A statement China English translation of the notice above When labeled with the CCC marking the product meets the applicable safety and EMC requirements for China This is a Class A product In a domest...

Page 53: ...da EN 60950 1 2006 A11 2009 A1 2010 A12 2011 CAN CSA C22 2 No 60950 1 07 A1 2011 UL 60950 1 2011 Safety NRTL National Recognized Test Laboratory USA Canada FCC CFR 47 Part 15 Class A ICES 003 Issue 5...

Page 54: ...w Zealand AS NZS CISPR22 2009 A1 2010 Class A Safety C Tick Korea KN22 Class A and KN 24 EMC KC China GB4943 1 2011 GB9254 2008 GB17625 1 2012 Safety and EMC CCC India IS 13252 Part 1 2010 Safety BIS...

Page 55: ...icted substances except where exemptions published in the RoHS2 Directive are applicable This statement is based on vendor supplied analysis or material certifications and or lab test results of the c...

Page 56: ...ogram For more information please visit China RoHS regulation page at official US export website http www export gov china doingbizinchina China RoHS Disclosure report Below table shows the presence o...

Page 57: ...Union s WEEE Directive 2002 96 EC came into force on August 2005 and were more recently amended in July 2012 This directive encourages the reuse recycling and recovery of WEEE and to improve the envi...

Page 58: ...tomers should Not discard equipment in household or office garbage Arrange proper recycling of unneeded equipment For the take back of Harmonic equipment customers must Collect the information require...

Page 59: ...s In addition to above listed standards and compliance regulations Harmonic products may also be compliant with other country specific environmental safety and EMC requirements Please contact Harmonic...

Page 60: ...Copyright 2016 Harmonic Inc All rights reserved...

Reviews: