About MediaCenter 2200B storage
LED state
Condition
Green, solid
A valid AC source is connected to the power supply, and the power
supply is operational.
Green (1 Hz blink)
AC is present, but the power switch on the front panel is off or in a
cold redundant state due to low system power load.
Green (2 Hz blink)
Power supply firmware updating.
Amber, blink
Power supply is operational, but experiencing a warning event.
Amber, solid
AC power is lost or a power supply is shut down.
CAUTION:
If two power supplies are used, they must be of the same type and have the
same maximum output power.
About MediaCenter 2200B storage
The MediaCenter 2200B provides 12 hot-swappable disk drives in a 2 x (4 +2) RAID set, and up to 48 TB
of usable storage.
Refer to the following table for supported RAID configurations.
Table 6-1: MediaCenter 2200B RAID configurations
Drives
RAID set
Capacity per drive
Storage capacity
12 SAS
2 x (4+2)
6 TB
48 TB
12 SAS
2 x (4+2)
4 TB
32 TB
12 SAS
2 x (4+2)
2 TB
16 TB
NOTE:
No other disk drive configurations are supported.
In SystemManager, use the “One-Click” function to create the file system and RAID set, and initialize the
file system. Follow the instructions in “Using One-Click Functions” in the
SystemManager User Guide
.
Refer to the following image to identify the numbering of drives.
Figure 6-11: MediaCenter 2200B drive numbering
For additional storage, you can connect the MediaCenter to the MediaStore 7200 via SAS.
Related information
About the file system configuration for MediaCenter 2200B with MediaStore 7200
on page 219
147
Spectrum System 8.4 Installation Guide