Installation and Wiring
EIO0000001505 12/2014
103
Detected Applicative Alarm
Overview
The ZARB18• Base Station implements 6 inputs: IN1…IN6.
Different sensors can be connected to these inputs.
These inputs are dedicated for applicative alarms.
Description
The detected applicative alarms are only displayed on the ZART•D Remote Device.
Factory settings:
You can configure the detected applicative alarm inputs with the eXLhoist Configuration Software
General Wiring Rules
The I/O and power supply cables should be AWG 16 (cross-sectional conductor area = 1.3 mm
2
).
The I/O and power supply cable lengths should not exceed 20 m (65.6 ft).
For more details, refer to Wiring Best Practices
.
Input
Description
IN1
Overload pre-alarm
IN2
Overload alarm
IN3
Over wind pre-alarm
IN4
Over wind alarm
IN5
Over speed alarm
IN6
Generic alarm
Summary of Contents for eXLhoist
Page 12: ...12 EIO0000001505 12 2014...
Page 34: ...Wireless Remote Control System 34 EIO0000001505 12 2014...
Page 52: ...52 EIO0000001505 12 2014...
Page 146: ...Using The Wireless Remote Control System 146 EIO0000001505 12 2014...
Page 200: ...eXLhoist Configuration Software 200 EIO0000001505 12 2014...
Page 213: ...EIO0000001505 12 2014 213 Harmony eXLhoist EIO0000001505 04 2014 Appendices...
Page 214: ...214 EIO0000001505 12 2014...